1.Description of the split electromagnetic acid flow meter:
ZFG-F split electromagnetic acid flow meter measurement principle is based on Faraday's law of electromagnetic induction, split electromagnetic acid flow meter by the sensor and converter components, the sensor installed in the measurement pipeline, the converter is installed within 30 meters from the sensor or within 100 meters, both between the shielded cable connection.Split electromagnetic acid flow meter sensor is the main components: measuring tube, electrode, excitation coil, iron core and yoke shell.
2.Features of the split electromagnetic acid flow meter:
·The measurement tube without obstruction of moving parts, no pressure loss, straight pipe requirements lower;
·The converter uses a new excitation method, low power consumption, zero stability, high accuracy. Flow range of up to 150: 1;
·The converter can be integrated with the sensor or separation type;
·Flow meter for the two-way measurement system, built-in three totalizer;
·The converter using surface mount technology (SMT), with self-test and self-diagnostic function
·For conductivity than 5μs / cm conductive fluid volume flow measurement
·The measurement tube without activity and blocking components, the pressure loss is small
·With different materials lining and electrode has good corrosion resistance
·Free from media, density, viscosity, temperature, pressure and conductivity
·Low frequency rectangular wave excitation, not susceptible to interference, can be stable and reliable
·The converter low energy consumption, easy to install, the user does not need debugging
3.Specification of the split electromagnetic acid flow meter:
Accuracy : ± 0.5%, ± 1%
Lining material: polyurethane, chloroprene rubber, poly tetrafluoroethane and so on
Electrode material: stainless steel, Hastelloy, titanium, platinum iridium alloy
Nominal diameter series DN: (mm)
Tetrafluoroethane lining: 5,10,15,20,25,32,40 ... 1200
Rubber lining: 10,15,20,25,32,40,50,65,80,100,125,150,200,250,300,350 ... 2000
Connection: flange clip, flange connection
Operating temperature: neoprene lining: -20 ~ +60 ℃; Polyurethane lining: -20 ~ +90 ℃ Polytetrafluoroethylene lining: -30 ~ + 180 ℃
Medium temperature: 0 ° C to 70 ° C, 0 ° C to 130 ° C (0 ° C to 180 ° C)
Nominal pressure: 1.0Mpa ~ 32Mpa
Protection class: IP65, IP68
Explosion-proof mark: ExibBT4
Working voltage: 220VAC, 24VDC
Working pressure: DN10-DN65: 2.5Mpa
DN80-DN150: 1.6Mpa
DN200-DN1600: 1.0Mpa
flow rate range is 0.5 ~ 10m / s
Output signal and load resistance: 0 ~ 10mADC, 0 ~ 1000Ω; 0 ~ 1000Hz; not less than 10KΩ;0 ~ 4 ~ 20mADC, 0 ~ 500Ω; 1 ~ 5V, 0 ~ 5V, not less than 10KΩ
Power supply: 220VAC ± 10%, 50Hz ± 5% 24VDC ± 10%
Straight pipe length: upstream ≥ 5DN, downstream ≥ 3DN;
Ambient temperature: -25 ℃ ~ +45 ℃ Relative humidity: 5% to 95%
power consumption: less than 25W
4.Flow range of the split electromagnetic acid flow meter:
Caliber Flow range Caliber Flow range
(mm) (m3/h) (mm) (m3/h)
φ15 0.06~6.36 φ450 57.23~5722.65
φ20 0.11~11.3 φ500 70.65~7065.00
φ25 0.18~17.66 φ600 101.74~10173.6
φ40 0.45~45.22 φ700 138.47~13847.4
φ50 0.71~70.65 φ800 180.86~18086.4
φ65 1.19~119.4 φ900 228.91~22890.6
φ80 1.81~180.86 φ1000 406.94~40694.4
φ100 2.83~282.60 φ1200 553.90~55389.6
φ150 6.36~635.85 φ1600 723.46~72345.6
φ200 11.3~1130.4 φ1800 915.62~91562.4
φ250 17.66~176.25. φ2000 1130.4~113040.00
φ300 25.43~2543.40 φ2200 1367.78~136778.4
φ350 34.62~3461.85 φ2400 1627.78~162777.6
φ400 45.22~4521.6 φ2600 1910.38~191037.6