1. Introduction
NOx gas converter is used for the application that using NO gas analyzer to measure NO2 or NOx. It can convert NO2 to NO in the air or from the stack. This is an optional equipment used before NO gas analyzer, which can got NOx (NO+NO2) value by converting NO2 to NO.
2. Features
High conversion rate under low temperature.
Up to 300ppm NO2 switching capacity
A long lifespan
The patented conversion tube structure
Micro processing controller intelligent temperature control
The temperature can be adjusted freely
With the temperature alarm
With the LED display
19 "rack enclosure and wall-mounted type optional
Easy for replacement of special switching tube design
3. Specifications
Working temperature: 365℃
Prewarming time: 30 minutes
Sample gas pressure: 1.5bar
Sample gas flow rate: 120L/h
Sample gas temperature: 5-80℃
Dew point: <10 C </span>
Environment temperature: 5-50℃
Storage and transportation temperature: -20 - 70℃
Relative humidity: <80%RH </span>
Power supply: 220VAC, 50/60Hz
Power consumption: about 400W
Eack installation: 19 ", 3U or wall-mounted (different type)
Weight: about 5.5Kg
The protection grade: IP20
The conversion efficiency >95% (new conversion tube)
The conversion tube service life: more than 12 months, depending on the concentration of NO2
The maximum capacity: 300ppm (flow 60L/h)
1. Introduction
NOx gas converter is used for the application that using NO gas analyzer to measure NO2 or NOx. It can convert NO2 to NO in the air or from the stack. This is an optional equipment used before NO gas analyzer, which can got NOx (NO+NO2) value by converting NO2 to NO.
2. Features
High conversion rate under low temperature.
Up to 300ppm NO2 switching capacity
A long lifespan
The patented conversion tube structure
Micro processing controller intelligent temperature control
The temperature can be adjusted freely
With the temperature alarm
With the LED display
19 "rack enclosure and wall-mounted type optional
Easy for replacement of special switching tube design
3. Specifications
Working temperature: 365℃
Prewarming time: 30 minutes
Sample gas pressure: 1.5bar
Sample gas flow rate: 120L/h
Sample gas temperature: 5-80℃
Dew point: <10 C </span>
Environment temperature: 5-50℃
Storage and transportation temperature: -20 - 70℃
Relative humidity: <80%RH </span>
Power supply: 220VAC, 50/60Hz
Power consumption: about 400W
Eack installation: 19 ", 3U or wall-mounted (different type)
Weight: about 5.5Kg
The protection grade: IP20
The conversion efficiency >95% (new conversion tube)
The conversion tube service life: more than 12 months, depending on the concentration of NO2
The maximum capacity: 300ppm (flow 60L/h)
Ubicación : NO.501,Building 4, International Innovation City, Zhenhua Road, 410007 Changsha,
Persona a contactar : Carol Zhong, +8673182244670