B2B Servicios
KE600A Series Close Loop Vector Control Inverter
|
Input |
Input voltage |
3AC 220V±15%, 3AC 380V±15%, 3AC 660V±15% |
Input frequency |
47~63Hz |
|
Output |
Output voltage |
0~Rated voltage |
Output frequency |
V/f:0~3000Hz, VC:0~300Hz |
|
Control |
Control mode |
V/f , SVC, VC, Torque control |
Feature |
Operation command mode |
Keypad control, Terminal control, Serial communication control |
|
Frequency setting mode |
Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes. |
|
Overload capacity |
150% 60s, 180% 10s, 200% 3s. |
|
Starting torque |
0Hz/180% (VC); 0.5Hz/150% (SVC) |
|
Speed adjustment range |
1: 1000 (VC); 1: 100 (SVC) |
|
Speed control precision |
±0.5% (SVC); ±0.02% (VC)) |
|
Carrier frequency |
0.5--16.0kHz, automatically adjusted according to temperature and load characteristics |
|
Frequency accuracy |
Digital setting: 0.01Hz |
|
Analog setting: maximum frequency ×0.05% |
|
|
Torque boost |
Automatically torque boost; manually torque boost 0.1%~30.0% |
|
V/f curve |
Three types: straight line, multiple points and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square) |
|
ACC/DEC mode |
Linear/S curve; four kinds of ACC/DEC time, range 0.1s~3600.0s |
|
DC braking |
DC braking when starting and stopping |
|
DC braking frequency: 0.0Hz~maximum frequency, braking time: 0.0s~36.0s; Braking current: 0.0%~100.0% |
|
|
Jog operation |
Jog operation frequency: 0.0Hz~maximum frequency Jog ACC/DEC time: 0.1s~3600.0s |
|
Simple PLC & multi-step |
Max. 16 steps speed running via built-in PLC or control terminal. |
|
speed operation |
|
|
Built-in dual PID |
Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) |
|
Automatic voltage regulation |
Keep output voltage constant automatically when input voltage fluctuating |
Control |
Common DC bus |
Common DC bus for several inverters, energy balanced automatically |
Function |
Torque control |
Torque control with/without PG |
|
Torque limit |
“Rooter” feature, limit the torque automatically and prevent frequent over-current tripping when running |
|
Wobble frequency control |
Multiple triangular-wave frequency control, special for spinning |
|
Timing/length/counting control |
Timing/length/counting control function |
|
Over-voltage & overcurrent stall control |
Limit current & voltage automatically when running, prevent frequent over-current & over-voltage tripping |
|
Speed tracking restart |
Start the running motor smoothly without impact, protect the safety of motor and load at the most |
|
Fault protection function |
Up to 30 fault protection including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function |
Special |
Motor switching |
Two groups of motor parameters to achieve two motors switching |
Functions |
Spare part |
Braking parts, IO extension card, differential input PG card, open collector input PG card, injection molding machine card, communication card, etc. |
|
Powerful host software |
Support KE600 parameter setting and real-time parameter monitor |
Terminals |
Input terminals |
Programmable DI: 7 on-off inputs, 1 high-speed pulse input, can extend 3 inputs*1 |
2 programmable AI: |
||
AI1: voltage -10~10V |
||
A12: voltage 0~10V or current 0/4~20mA |
||
Output terminals |
1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output), can extend 1 output*1 |
|
1 relay output, can extend 1 output*1 |
||
2 analog output: 0/4~20mA or 0~10V |
||
Communication terminal*2 |
Offer RS485 communication interface, support MODBUS-RTU communication protocol |
|
Human |
LED display |
Display frequency setting, output frequency, output voltage, output current, etc. |
&Machine |
||
interface |
Multifunction key |
QUICK/JOG key, can be used as multifunction key |
Environment |
Ambient temperature |
-10℃~40℃, derated 4% when the temperature rise by each1℃ (40℃~50 ℃). |
Limit |
Humidity |
90%RH or less (non-condensing) |
|
Altitude |
≤1000M: output rated power, >1000M: output derated |
|
Storage temperature |
-20℃~60℃ |
|
Storage atmosphere |
Indoor, without direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip, salt, vibration, etc. |
Buen trato: comprar del vendedor
Esta página es acerca de los importadores y exportadores de KE600A Series Close Loop Vector Control Inverter Buscar en la categoria : B2B Servicios Buscar en la categoria : vector, loop, ke600a, close, control, series, inverter |
Viernes 09 septiembre 2016
Cantidad : 400 - Precio : 8,00 €
Déstokage 400 detectores de humo EI ELECTRONICS EI650 fabricado en Europa con una batería de litio hasta autónoma en 2026 (20 estuches de 20 detectores con tornillos de montaje de pared y manual de instrucciones en francés). CARACTERÍSTICAS TÉCNICAS - Botón de prueba y descanso...
Miércoles 05 agosto 2015
Nos complacemos en ofrecerle nuestra máquina, disponible para venta: * Heidelberg MOVP-S+ - Año 1987 48x65 - 4 colores - CPC 1.01 - Mojado ALCOLOR - Baldwin con refrigeración - Alimentador de hojas Mabeg - Marcador continuo - Control de la delantera y de doble hoja - Sistema de...
Jueves 26 diciembre 2024
Cantidad : 10 - Precio : 246,00 €
L'alarme piscine sensor premium pro est un système de détection de chute, destiné aux piscines familiales enterrées (dimensions maximales : 10x5m), conforme à la norme nf p90-307 a1. L'alarme piscine Sensor premium pro est le détecteur d'immersion pour piscines privées le plus vendu...