Fire Resistant Control Cable (2-4cores) 300-500V
|
Conductor |
rated voltage 300/500v |
||||||
|
Without Earth Conductor |
With Earth Conductor |
|||||
No. of Core X Cross Section |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Approx. Weight |
Nominal Overall Diameter |
Approx. Weight |
No*mm² |
No./mm |
mm |
mm |
mm |
kg/km |
mm |
kg/km |
2 Cores |
|||||||
2x1.5 |
7/0.53 |
0.5 |
0.5 |
7.7 |
70 |
8.2 |
80 |
2x2.5 |
7/0.67 |
0.5 |
0.5 |
8.8 |
100 |
9.6 |
120 |
2x4 |
7/0.85 |
0.5 |
0.5 |
9.8 |
140 |
10.5 |
170 |
3 Cores |
|||||||
3x1.5 |
7/0.53 |
0.5 |
0.5 |
8.7 |
90 |
10.5 |
100 |
3x2.5 |
7/0.67 |
0.5 |
0.5 |
9.5 |
125 |
10.7 |
150 |
3x4 |
7/0.85 |
0.5 |
0.5 |
11.5 |
180 |
12.5 |
220 |
4 Cores |
|||||||
4x1.5 |
7/0.53 |
0.5 |
0.5 |
10.3 |
105 |
12.2 |
120 |
4x2.5 |
7/0.67 |
0.5 |
0.5 |
11 |
155 |
13 |
190 |
4x4 |
7/0.85 |
0.5 |
0.5 |
12.5 |
255 |
13.5 |
270 |
Description of Fire Resistant Control Cable (2-4cores) 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 times of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
|
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
NF C32-070-2.3(CR1) |
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
|
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
|
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; |
|
CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; |
|
CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; |
|
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fire Resistant Control Cable (2-4cores) 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
Buen trato: comprar del vendedor
Esta página es acerca de los importadores y exportadores de Fire Resistant Control Cable (2-4cores) 300-500V Buscar en la categoria : B2B Servicios Buscar en la categoria : 500v, control, fire, 4cores, resistant, cable |
Viernes 27 septiembre 2013
Cantidad : 7 - Precio : 1,00 €
Con mucho placer, le ofrecemos, en lote, nuestras dos máquinas siguientes disponibles para la venta: Ryobi 512, Año 1997 36,5x52 - 2 Colores - S/N 1582 - ca. 7 Mio impresiones, Mojado , Marcador continuo, Control de la delantera y de doble hoja, Sistema de ajuste rápido, Cilindro...
Lunes 07 septiembre 2015
- Feature (click here for details) - - Under the LAN can support more than 10 simultaneous client connections cameras, image lag within 100 milliseconds, supports standard streaming media network protocols, network 8 M per channel bit rate case, no mosaic - The DSP processor...
Jueves 16 mayo 2024
Société italienne producteur d' un système innovant pour la réalisation de l'isolation acoustique verticale au niveau des dalles de séparation entre les étages Le produit nommé PHONO PAR est un tissus en polyester épandu couplé avec un film synthétique qui se pose entre le ragréage...