Varios / Descuento
Infrared Thermopile Sensor |
|
Parameter |
Min. |
Typ. |
Max. |
Unit |
Conditions |
|
Chip size |
|
1.1X1.1 |
|
mm² |
|
|
Sensitive area |
|
0.35X0.35 |
|
mm² |
|
|
Detection angle |
|
90 |
|
° |
|
|
Thermopile resistance |
80 |
98 |
115 |
KΩ |
Temp=25℃ |
|
Noise voltage |
|
38 |
|
nV/Hz½ |
Temp=25℃ |
|
NEP |
|
0.23 |
|
nW/Hz½ |
Blackbody=500K,1Hz@25℃ |
|
Voltage Response |
|
20.11 |
|
Vm m²/w |
Blackbody=500K,1Hz@25℃ |
|
Responsivity |
134 |
164 |
194 |
V/w |
Blackbody=500K,1Hz@25℃ |
|
Temp. coefficient of resistance |
|
0.06 |
|
%/℃ |
Temp=25℃~ 75℃ |
|
Time constant |
|
<=13</span> |
|
ms |
|
|
Specific detectivity |
|
1.51 E08 |
|
cmHz½/w |
Blackbody=500K,1Hz@25℃ |
|
NTC Resistance |
|
100±3% |
|
KΩ |
25℃ |
|
NTC β |
|
3950±1% |
|
K |
25/50℃ |
FAQ
Is Wave Soldering Recommended?
Wave soldering is likely to cause degradation of product performance. Wave soldering is not recommended. Generally we recommend to solder by hand.
Can PIR Sensor Detect Animals?
Do PIR Sensors Work Through Glass?
What Is The Package?
What are the Factors that Affect the Performance of the Product?
Senba sensing technology co ltd is a pir sensor manufacturers, we provide china pir, thermopile temperature sensor, thermopile ir sensor, thermopile detector, passive ir motion sensor and etc. Welcome to contact us.
Buen trato: comprar del vendedor
|
Esta página es acerca de los importadores y exportadores de Infrared Thermopile Sensor Buscar en la categoria : Varios / Descuento Buscar en la categoria : sensor, infrared, thermopile |
Thursday 26 May 2016
Cantidad : 1set - Precio : 130.62USD
Ⅰ.Introduction MEWOI7300 High Accuracy Clamp Leaker is specially designed for AC leakage current measurement. It obtains the latest CT and digital integration technology, with characteristics of small volume, high accuracy and perfect function. It is widely used in electric power...
Friday 15 April 2016
Cantidad : 100 - Precio : 10 000,00 €
MMT Moisture Management Tester Norme di controllo: AATCC 195, SN 1689,1, GB / T 21.655,2 Applicazioni Moisture Management Tester: La Direzione del tester di umidità (MMT) è un'apparecchiatura per misurare le dinamiche proprietà di trasporto di liquidi di tessuti, come tessuti...
Tuesday 27 October 2026
Cantidad : 999 sets - Precio : negotiated
Calor sello Tester está diseñadoprofesionalmente para la medida exacta decinco grupos de sellado de tiempo, temperaturay presión. Gradiente térmico Seal Tester espara la determinación de la heatsealability deuna superficie o capa de sellador depelículas, laminados, materiales compuestos...