Bienes de equipo
CZ3000 Temperature Converter Signal Conditioner |
|
|
CZ3076 |
CZ3079 |
|
|
CZ3071 |
1/2 |
2/2 |
|
|
1/1 |
|
|
|
|
Input Signal |
Pt100,Cu100,Cu50 |
Pt100,Cu100,Cu50 |
Pt100,Cu100,Cu50 |
|
Output Current/Load Resistance |
0~20mA,4~20mA / RL ≤300Ω |
0~20mA,4~20mA / RL ≤300Ω |
0~20mA,4~20mA / RL ≤300Ω |
|
Output Voltage/Load Resistance |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
|
Fault Current of Overrange/Underrange |
IH≈20.8mA/IL≈3.8mA |
IH≈20.8mA/IL≈3.8mA |
IH≈20.8mA/IL≈3.8mA |
|
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
|
Supply Voltage |
20~35V DC |
20~35V DC |
20~35V DC |
|
Power Reverse Protection |
Support |
Support |
Support |
|
Current Consumption(Supply voltage: 24V) |
≤35mA |
≤55mA |
≤55mA |
|
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
|
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
|
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
|
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
|
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
|
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Suitable Field Apparatus |
2-or 3-wire RTD |
2-or 3-wire RTD |
2-or 3-wire RTD |
|
|
|
|
|
|
|
CZ3072 |
CZ3074 |
CZ3079.TC |
|
1/1 |
1/2 |
2/2 |
|
|
Input Signal(Customized mV signal) |
T、E、J、K、N、R、S、B |
T、E、J、K、N、R、S、B |
T、E、J、K、N、R、S、B |
|
Internal CJC Temperature Range |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
CJC Precision |
±1℃ |
±1℃ |
±1℃ |
|
Output Current/Load Resistance |
0~20mA,4~20mA / RL≤300Ω |
0~20mA,4~20mA / RL≤300Ω |
0~20mA,4~20mA / RL≤300Ω |
|
Output Voltage/Load Resistance |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
0~5V,1~5V / RL ≥20kΩ |
|
Fault Current of Overrange/Underrange |
IH≈20.8mA/IL ≈3.8mA |
IH≈20.8mA/IL ≈3.8mA |
IH≈20.8mA/IL ≈3.8mA |
|
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
|
Supply Voltage |
20~35V DC |
20~35V DC |
20~35V DC |
|
Power Reverse Protection |
Support |
Support |
Support |
|
Current Consumption(Supply voltage: 24V) |
≤35mA |
≤55mA |
≤55mA |
|
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
|
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
|
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
|
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
|
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
|
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Suitable Field Apparatus |
TC and mV signal sensor |
TC and mV signal sensor |
TC and mV signal sensor |
|
|
|
|
|
|
|
1/1:CZ3077 |
1/1:CZ3177 |
1/1:CZ3277 |
|
2/2:CZ3078 |
2/2:CZ3178 |
2/2:CZ3278 |
|
|
Input Signal |
Pt100,Cu100,Cu50 |
T、E、J、K、N、R、S、B |
Pt100,Cu100,Cu50 |
|
(Customized mV signal) |
T、E、J、K、N、R、S、B |
||
|
Internal CJC Temperature Range |
|
-20~+60℃ |
-20~+60℃ |
|
CJC Precision |
|
±1℃ |
±1℃ |
|
Output Current |
4~20mA |
4~20mA |
4~20mA |
|
Load Resistance |
RL ≤(Ue -12)/0.021Ω |
RL ≤(Ue -12)/0.021Ω |
RL ≤(Ue -12)/0.021Ω |
|
Fault Current of Overrange/Underrange |
IL ≈20.8mA/IL ≈3.8mA |
IL ≈20.8mA/IL ≈3.8mA |
IL ≈20.8mA/IL ≈3.8mA |
|
Fault Current of Line Break |
I≈20.8mA |
I≈20.8mA |
I≈20.8mA |
|
Loop Supply Voltage(Ue) |
12~30V DC |
12~30V DC |
12~30V DC |
|
Power Reverse Protection |
Support |
Support |
Support |
|
Temperature Drift |
0.01%F.S./℃ |
0.01%F.S./℃ |
0.01%F.S./℃ |
|
Response Time (0~90%) |
≤1s |
≤1s |
≤1s |
|
Dielectric Strength |
1500V AC;1min |
1500V AC;1min |
1500V AC;1min |
|
Insulation Resistance |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
≥100MΩ; 500V DC |
|
EMC Standards |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
GB/T 18268(IEC 61326-1) |
|
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
-20℃~+60℃ |
|
Suitable Field Apparatus |
2-or 3-wire RTD |
TC sensor,mV signal |
RTD,TC sensor |
Signal conditioners are electrical devices, which are connected between the industrial field instrument and the control room. CHENZHU's signal conditioner complete in specifications.
Buen trato: comprar del vendedor
|
Esta página es acerca de los importadores y exportadores de CZ3000 Temperature Converter Signal Conditioner Buscar en la categoria : Bienes de equipo Buscar en la categoria : conditioner, converter, temperature, signal, cz3000 |
Tuesday 23 December 2025
Precio : illimité
Somos una empresa tunecina ( SETECSTRA ) y ofrecemos pollo congelado de thailando en contacto con nosotros pronto : MR vei alain Tokpa o +225 49875663 o alainvei@outlook.fr CIF SAFE WORLD PORTUARIAS 610 USD / MT Producto : Cualquier pollos congelados Halal . Tipo: Congelado ...
Tuesday 16 February 2016
Cantidad : 10,000MT - Precio : 210 USD/MT CIF
Refined Sugar Icumsa 45 RBU, Icumsa 150, Icumsa 600-1200 Competitive prices & Current cropping Quality guarantee ICUMSA 45 is a highly refined sugar, and it is easily recognizable by its distinctive sparkling white color and pure Sucrose taste. It is suitable for human consumption...
Saturday 11 July 2015
Cantidad : 100 - Precio : $45
Features: 1 . Espesor de 10 mm , super delgado ; 2 . Tipo de instalación: Embedded / Suspendido; 3 . Chorro de arena de plata brillante para 10mm serie thichness ; 4 . Importada placa de difusión Corea, transmitancia hasta 93% ; 5 . 0.2W 2835 LED, alta eficacia luminosa , la...