EST-HS2 Manual Durometer Test Stand |
Operating Type |
Inverter to specimen |
Loading Method |
Cam loading |
Loading Stroke |
18 mm |
Specimen Thickness |
60 mm |
Throat Depth |
65 mm |
Support Table(dia.) |
Φ116 mm |
Lifting Adjustment |
Screw adjustment |
Table Adjustment |
Three-point leveling |
Net Weight |
5.6 kg (excluding S weight) |
Package Weight |
7.6 kg (excluding D weight) |
Durometer Operating Test Stand Operation
1. Unpacking
1.1 Take out the durometer test stand from the carton and remove the two packing foam inserts
1.2 Unbundle the webbing strap and remove the foam sheet and foam pad
1.3 Install the handle of durometer stand
2. Weights Selection of Durometer Stand
3. Simple Adjust for Support Table
In most applications, simple adjustments are usually sufficient for the durometer operating stand.
3.1 Release Tighten screw, turn height adjust knob, let durometer stand move down to contact on the support table.
3.2 Adjust 2 Vernier Knobs. Let the face of the support table be fully fitted to the bottom of the durometer operating stand.
4. Install Durometer Operating Test Stand
4.1 Lift Handle to put down durometer stand
4.2 Tighten Durometer Stand through Tighten Knob
5. Fine Adjust for Support Table
When accurate measurements or calibration are performed, fine adjustments to the support table may be required.
5.1 Set the test mode of the durometer test stand to Timing Mode and set its Dwell Time as long as possible, such as 99 s. (Lengthening the time period for reading lock)
5.2 Put standard thickness block between press foot and the support table.
5.3 Lift the handle to make the indenter of the durometer stand press onto the support able through the hole on the block.
5.4 Now the readings are displayed on the durometer test stand. Adjust the Vernier Knobs to make the reading as larger as possible to near 50HS.
Note:
1. If adjustment is not finished in setting time, lift the durometer operating stand then press again for renewing the timing.
2. Because the indenter is often pressed into the table, the reading does not must be "50.0 HS", It is usually less than 50.0 HS. Just adjusting the table to the location of the maximum reading.
3. Too large or too fast adjusting may damage the indenter (especially for type D). So it is better to pre-adjust with the durometer test stand loaded. Or lift up and press down the durometer stand in adjustment.
As a measuring instruments manufacturing company, we have types of force gauge meter for sale, if you have needs, please contact us.
Buen trato: comprar del vendedor
Esta página es acerca de los importadores y exportadores de EST-HS2 Manual Durometer Test Stand Buscar en la categoria : Informática Buscar en la categoria : durometer, stand, test, manual |
Miércoles 20 mayo 2015
AI101P Single Port KVM over IP The KVM over IP technology (IP-KVM) combines digital remote KVM access via IP networks with comprehensive and integrated system management. The IP-KVM defines a new class of remote KVM access devices that can save your money, time, space, and equipment...
Domingo 15 marzo 2015
TAYSAN MAKINA CO. SARL. Es una empresa que hace que la producción de tipos de máquinas totalmente automáticas y manuales de R para la fabricación de azúcar duro en cubos de Turquía y también máquinas para envasado de alimentos diversos y terrones de azúcar desde diez años de experiencia...
Lunes 04 marzo 2013
Cantidad : 30 - Precio : $395.00
It's not just phone we're talking about... it's smart phone... it's Samsung GALAXY S III. It has the looks and a symmetry which would make you proud to hold it in your hands. You couldn't ask for more imposing façade than its 4.8 inches HD Super AMOLED high-definition display. It delivers...