Fire Resistant Single Core 300-500V
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Nominal Cross Section Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Without Earth Conductor |
|
|
mm² |
No./mm |
mm |
mm |
Nominal Overall Diameter |
Approx. Weight kg/km |
|
mm |
|||||
|
1.5 |
7/0.53 |
0.5 |
0.5 |
4.4 |
29 |
|
2.5 |
7/0.67 |
0.5 |
0.5 |
4.9 |
40 |
|
4 |
7/0.85 |
0.5 |
0.5 |
5.5 |
55 |
Description of Fire Resistant Single Core 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 time of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
|
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
|
|
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
|
NF C32-070-2.3(CR1) |
|
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
|
|
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
|
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
|
|
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
|
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; |
|
|
CEI 20-37/2-1 ; BS 6425-1* |
|
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; |
|
|
CEI 20-37/2-2 ; BS 6425-2* |
|
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; |
|
|
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
|
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fire Resistant Single Core 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
As a reliable electric cable factory, we can offer sorts of xlpe insulated cable for sale, if you are interested, please contact us.
Buen trato: comprar del vendedor
|
Esta página es acerca de los importadores y exportadores de Fire Resistant Single Core 300-500V Buscar en la categoria : Búsqueda/compra Buscar en la categoria : 500v, resistant, fire, core, single |
Tuesday 08 September 2015
Module parameters HD-720P-38*38mm 1.0megapixel low-illumination HD web camera Network Camera - Sensor type 1/4 inch、1.0megapixel , CMOS low-illumination width dynamic sensor - Minimum illumination Color: 1 Lux/F1.2, black and white: 0.02Lux/F1.2 - Electronic shutter 1/5 second ~ 1/50...
Monday 23 May 2016
Cantidad : 100000 met - Precio : 0.280usd
Thomsun Industries LLC is a professional PPR manufacturers and ppr suppliers in Dubai UAE. T-Mech pressure piping system is considered to be the best carrier of potable water, using the revolutionary raw material of PPR-80 of Borouge brand. T-Mech PPR major products range covers...
Thursday 14 March 2013
Cantidad : 10 - Precio : 1 000,00 €
Origin China Model Number 061212413 Brand Name Anilutum Feature Windproof Gender Men's Material Wool Style Sleeveless Anilutum Brand Monty Aimo Monteamor classic aristocratic top mink collar leather Brand: Anilutum Style: Fashion Type: Men's Suit Online: 9AM-5PM...