Varios / Descuento
Fire Resistant Single Core 450-750V
|
Nominal Cross Section Area |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Overall Diameter |
mm2 |
No./mm |
mm |
mm |
1.5 |
7/0.53 |
0.7 |
3.5 |
2.5 |
7/0.67 |
0.8 |
4.1 |
4 |
7/0.85 |
0.8 |
4.6 |
6 |
7/1.04 |
0.8 |
5.2 |
10 |
7/1.35 |
1 |
6.5 |
16 |
7/1.70 |
1 |
7.6 |
25 |
7/2.14 |
1.2 |
9 |
35 |
7/2.52 |
1.2 |
10.2 |
50 |
19/2.52 |
1.4 |
11.8 |
70 |
19/2.14 |
1.4 |
13.4 |
95 |
19.2.52 |
1.6 |
15.8 |
150 |
37/2.52 |
1.8 |
18.8 |
185 |
37/2.52 |
2 |
21 |
240 |
37/2.52 |
2.2 |
25.7 |
300 |
37/2.52 |
2.4 |
28.6 |
400 |
61/2.85 |
2.6 |
32 |
500 |
61/3.20 |
2.8 |
35.5 |
630 |
127/2.52 |
2.8 |
39.5 |
Description Of Fire Resistant Single Core 450-750V
Rated voltage: 450/750V
Basic standard: BS7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 time of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
|
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
NF C32-070-2.3(CR1) |
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
|
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
|
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; |
|
CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; |
|
CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; |
|
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fire Resistant Single Core 450-750V
This xlpe cable is used in public buildings or infrastructure projects where the fire and toxic gas may cause damage to people or equipment, such as fire extinguishing systems, sprinklers, control panels, and exit lights in high-rise buildings, hotels, hospitals, subways, and public facilities
If you want to know more details of 450 750v cable meaning, please visit our website.
As a reliable electrical cable factory, we will do our best to meet all the needs of customers.
Buen trato: comprar del vendedor
Esta página es acerca de los importadores y exportadores de Fire Resistant Single Core 450-750V Buscar en la categoria : Varios / Descuento Buscar en la categoria : 750v, fire, resistant, single, core |
Lunes 04 marzo 2013
Cantidad : 30 - Precio : $395.00
It's not just phone we're talking about... it's smart phone... it's Samsung GALAXY S III. It has the looks and a symmetry which would make you proud to hold it in your hands. You couldn't ask for more imposing façade than its 4.8 inches HD Super AMOLED high-definition display. It delivers...
Lunes 20 julio 2015
Maroc vente fournisseurs, tissus technique, tapis isolation acoustique, grossistes, producteurs, import-export Société italienne spécialisée en production de tissus techniques pour construction et travaux publics cherche importateur exclusif au Maroc pour tapis isolation acoustique...
Sábado 19 julio 2014
Cool White LED with color temperature 7000K to 7500K implies a mild blue tint in the white glow. Cool White is preferred in many applications because the light they output makes items illuminated appear crisper. Cool White is often preferred in bathrooms and other task areas. Note...