Informática
Automatic Electrical Safety Tester |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Withstand Voltage Test (AC/DC) | Insulation Resistance Test (IR) | ||||
| Voltage Range | Accuracy | Current Range | IR Range | Accuracy | Voltage Range |
| 100~4000V | ± (5%+3V) | AC: 0.10~20.00mA DC: 0.10~12.00mA |
1.00~2000MΩ | 5% + 0.5MΩ | DC100~1000V |
| Leakage Current Test (LLC) | Grounding Resistance Test (GR) | ||||
| LLC Range | Accuracy | Voltage Range | GR Range | Accuracy | Output Current |
| 0.10~20mA | ± (0.3%+5uA) | AC10.0~300.0V | 0~600mΩ | ± (5%+2mΩ) | AC1.00~30.00A |
| Power Test | |||||
| Voltage | Current | Power | PF | Accuracy | Test Time |
| 10~300V | 0.010~20.00A | 1.0~6000.0W | 0.2~1.0 | Class 0.5 | 0~999.9s |
What's the test method of Automatic Electrical Safety System?
Pls. note that the DC high voltage output is a negative voltage, and the ground is a positive. When testing capacitance, there is a charging process when voltage is applied to both ends of the capacitor. At this time, there is a charging current in the test circuit. When the current is greater than the set leakage current value, the withstand voltage tester will alarm to interrupt the test , it cannot be proceed. Therefore, when the safety tester is testing, the voltage should be increased slowly, and the charging current should be less than the set leakage current value until the test voltage is specified, and the test should be performed. It is not possible to use a fixed voltage, reset-start method for testing. In the AC circuit, it is equivalent to the resistance in the DC circuit. […more…]
Buen trato: comprar del vendedor
|
Esta página es acerca de los importadores y exportadores de Automatic Electrical Safety Tester Buscar en la categoria : Informática Buscar en la categoria : tester, safety, electrical, automatic |
Tuesday 31 March 2026
Established in 1979. Hsing Wei has built itself in good quality and excellent performance printing crafts and also been related with good after-sales service to serve flexible packaging industry. For satisfying plastic film printing machine, plastic material printing machine quality...
Tuesday 31 March 2026
▲VE-30RFM RX (Front / Rear) ▲VE-30RFM TX (Front / Rear) VE-30RFM HDMI to RF Matrix Extender is designed to convert HDMI signal to HD digital TV signal based on DVB-T CATV signal, it uses 64QAM mode to realize the HD digital TV signal conversion and transmit via coaxial cables for...
Wednesday 14 September 2016
Cantidad : 5000 - Precio : 50,00 €
Gland Packing Globe Valves ( Straight- Through Type) DIN Standard Gland Packing Globe Valve DIN Globe valve DIN Stop valve DIN Absperrventil Durchgangsform DIN Válvulas de globo DIN ventil uzavírací s klasickou ucpávkou přímý DIN Standard seteventiler med pakkboks (rett løp...)