Informática
ACREL ADL SERIES DIN RAIL ENERGY METER |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type |
ADL10-E |
ADL100-ET |
ADL200 |
|
|
Voltage |
Reference voltage |
AC 220V |
AC 220V |
AC 220V |
|
Reference frequency |
45-65 Hz |
50Hz |
50Hz |
|
|
Consumption |
<10VA( Single phase)</span> |
<10VA</span> |
<10VA</span> |
|
|
Current |
Maximum current |
60A |
60A,100A |
80A |
|
Starting current |
0.004 Ib |
4‰Ib |
0.01A |
|
|
Consumption |
<4VA(Maximum current)</span> |
<4VA</span> |
<1VA</span> |
|
|
Measurement performance |
Accuracy |
Class 1 |
kWh Class 1 |
kWh Class 0.5 |
|
Standards compliant |
IEC 62053-21: 2003 |
IEC 62053-21: 2003 |
IEC 62053-21: 2003 |
|
|
Pluse |
Pluse width |
80+20 ms |
80±20ms |
80±20ms |
|
Pluse constant |
3200 imp/kWH |
1600imp/kWh |
1000imp/kWh,10000imp/kWh |
|
|
Communication |
Interface |
RS485 |
RS485(A+、B-) |
RS485 |
|
Protocol |
Modbus-RTU |
Modbus-RTU |
Modbus-RTU |
|
|
Outling |
L*W*H(mm) |
18*88*70 |
88*36*70 |
90*36*65 |
|
Temperature range |
Work |
-25℃-55℃ |
-25℃~55℃ |
-25℃-55℃ |
|
Storage |
-40℃-70℃ |
-40℃~70℃ |
-40℃-70℃ |
|
|
Humidity |
≤95%(No condensation) |
≦95% (No condensation) |
≦95% (No condensation) |
≦95% (No condensation) |
|
Altitude |
<2000m</span> |
<2000m</span> |
<2000m</span> |
<2000m</span> |
|
Type |
ADL400 |
ADL3000 |
|
|
Voltage |
Reference voltage |
3*57.7/100V, 3*220/380V, 3*100V, 3*380V |
3*57.7/100V,3*220/380V,3*100V,3*380V |
|
Reference frequency |
45-65 Hz |
50Hz |
|
|
Consumption |
<10VA( Single phase)</span> |
<10VA(Single phase)</span> |
|
|
Current |
Maximum current |
6A,80A |
6A,80A |
|
Starting current |
Direct connect: 0.004 Ib;Connect via: 0.001 In |
Direct connect: 0.004lb;Connect via: 0.001ln |
|
|
Consumption |
<4VA(Single phase rated current)</span> |
<1VA(Single phase rated current)</span> |
|
|
Measurement performance |
Accuracy |
Class 0.5S |
Class 0.5 |
|
Standards compliant |
IEC 62053-21: 2003 |
IEC 62053-22: 2003 |
|
|
Pluse |
Pluse width |
80+20 ms |
80+20 ms |
|
Pluse constant |
400imp/kWH,6400imp/kWH |
400imp/kWH,6400imp/kWH |
|
|
Communication |
Interface |
RS485 |
RS485 |
|
Protocol |
Modbus-RTU |
Modbus-RTU |
|
|
Outling |
L*W*H(mm) |
72*88*70 |
126.5*88*69.5 |
|
Temperature range |
Work |
-25℃-55℃ |
-25℃~55℃ |
|
Storage |
-40℃-70℃ |
-40℃~70℃ |
|
|
Humidity |
≤95%(No condensation) |
≦95% (No condensation) |
≦95% (No condensation) |
|
Altitude |
<2000m</span> |
<2000m</span> |
<2000m</span> |
Working principle Of Din Rail Energy Meter
ADL Series 3 phase kwh meter din rail use electronic circuits/chips to measure electrical energy; With partial pressure resistance or voltage signal into voltage transformer can be used for electronic measurement of small signal and current signal in the shunt or current transformer can be used for electronic measurement of small signal, using special power measurement chip will transform a good voltage and current signals are analog or digital multiplication, and electricity were accumulated, and then output frequency is proportional to the power of the pulse signal, Digital display after microcomputer processing.
ADL Series Din Rail Wireless Energy Meter FAQs
How To Calculate Maximum Demand In Energy Meter?
We will write the maximum demand function into the program of the energy meter, just need to click the button to turn the page to view the maximum demand.
How Energy Meter Calculate Power Factor?
Our energy meter has the function of measuring the power factor, and the corresponding power factor can be directly viewed on the display interface.
How Energy Meter Works?
When the energy meter is connected to the circuit under test, it will sample the voltage, current and other signals on the line to the chip, and then send to MCU through pulse, and then complete the calculation and display of various power parameters.
Now the price of 3 phase power meter modbus is reasonable, anything you need, please contact us.
Buen trato: comprar del vendedor
|
Esta página es acerca de los importadores y exportadores de ACREL ADL SERIES DIN RAIL ENERGY METER Buscar en la categoria : Informática Buscar en la categoria : rail, acrel, energy, series, meter |
Monday 07 September 2015
- Feature (click here for details) - - Under the LAN can support more than 10 simultaneous client connections cameras, image lag within 100 milliseconds, supports standard streaming media network protocols, network 8 M per channel bit rate case, no mosaic - The DSP processor...
Wednesday 20 January 2016
Cantidad : 10000 pcs - Precio : 45000 euros
VENTE STOCK: Vêtement pour enfant de 3 à 12 ans, invendus collection Printemps/Été 2015 Stock total de 10000pcs en vente à partir de 45000 euros. Vente partielle acceptée sous condition d'un minimum de 2000pcs/commande, prix à négocier. Production en petite série, 70pcs/modèle...
Saturday 25 June 2016
Aceite de oliva virgen extra de la más alta calidad producido en la región de Marrakech en Marruecos. Los siguientes paquetes están disponibles: Botella de vidrio de 250 ml Botella de vidrio de 500 ml Botella de cristal de 750 ml botella 1 L PET Botella de PET de 5 litros...