Informática
ACREL DJSF SERIES DC ENERGY METER |
Technical parameters |
Indicators |
||
Input |
Nominal value |
Voltage input range |
Current input |
DC 0-1000V |
Shunt:0-75mV; |
||
See the physical wiring diagram |
Hall sensor:0-20mA、4-20mA、0-5V,0-10V and so on. |
||
Overload |
1.2 times rated (continuous); 2 times rated/1 second; |
||
Power consumption |
Voltage: ≤0.2VA, current ≤0.1VA |
||
Accuracy class |
Class 1 |
||
Function |
Display |
8-bit segment LCD screen (LCD) |
|
Communication Interface |
RS485, infrared |
||
Communication protocol |
Modbus-RTU, DL/T 645-2007 |
||
Switch |
Switch output |
2 Relay outputs, 2A/30VDC or 2A/250VA |
|
Switch input |
2 dry contact inputs |
||
Pulse output |
A second pulse output, a energy pulse output |
||
See the SYS->PLUS display in the meter menu setting |
|||
For example: The meter displays 100, which is 100imp/kWH |
|||
Power Supply |
Voltage range |
AC/DC 85-265V or DC24V(±10%) or DC48V(±10%) |
|
Power consumption |
≤ 3W |
||
Power frequency withstand voltage |
Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1minPower supply // Relay output // Voltage input // Current input 3kV/1minPulse output // Communication interface // Switch input 2kV/1min |
||
Insulation resistance |
≥ 40M Ω |
||
Average barrier-free working hours |
≥50000h |
||
Environment |
Temperature |
Normal operating temperature: -25 °C ~ +65 °C; |
|
Limit working temperature: -40 °C ~ +70 °C; |
|||
Storage temperature: -40℃~+80℃ |
|||
Humidity |
≤93%RH, no condensation, no corrosive gas |
||
Altitude |
≤2500m |
How Does A DJSF Series DC Energy Meter Work?
DJSF1352-RN has two channels dc circuits input. The input voltage shall not be higher than 120% of the rated input voltage of the product. 1A fuse shall be installed at the voltage input end. The current input should be external shunt or Hall current sensor. The instrument provides RS485 communication interface and supports Modbus-RTU protocol. Theoretically, up to 128 instruments can be connected on a line at the same time. Each instrument can set its Addr and baud, and also can be selected by setting.
DJSF Series DC Energy Meter FAQs
what is a DJSF DC energy meter?
DJSF dc energy meter with rs485 is designed for DC screen, solar power supply, telecom base station, subway and other applications.
how does a DJSF DC energy meter work?
The DC voltage and the DC current are measured separately with two DMM, and the results are multiplied to get the DC power.
How does a DJSF energy meter Installation?
use 35mm guide rail which is convenient and quick to install.
Which signal input does DJSF dc energy meter support?
voltage supports 1000V input, current supports shunt (0-75mV), Hall sensor (0-20mA, 4-20mA, 0-5V) access.
Now the price of power meter for solar panels is low, if you are interested, please contact us.
Buen trato: comprar del vendedor
Esta página es acerca de los importadores y exportadores de ACREL DJSF SERIES DC ENERGY METER Buscar en la categoria : Informática Buscar en la categoria : djsf, meter, energy, series, acrel |
Jueves 10 junio 2010
SIAM-SUWAN-INTERNATIONAL-COMPANY-LTD est une societee franco-thailandaise etabli a Songkhla dans le sud de la thailande qui commercialise des produits en direct des grands fournisseurs thailandais sans intermediaires,et qui vous offre des services en francais. RED-BULL non gazeux...
Lunes 07 marzo 2016
Bubble Bath Spa Massager MSW-104 Bubble Bath Spa Massager is a new generation of home spa massager and is optimized for use in bath with the quality of tranquility, relaxing and luxury life. Configuration of MSW-104 is One-Touch Control Panel with Minimal and fashionable design...
Martes 08 marzo 2016
Cantidad : 100~500
Bubble Bath Spa Massager MSW-104 Bubble Bath Spa Massager is a new generation of home spa massager and is optimized for use in bath with the quality of tranquility, relaxing and luxury life. Configuration of MSW-104 is One-Touch Control Panel with Minimal and fashionable design...