220V/0.4-800kW Construction All-in-one Machine
|
Item |
Specifications |
|
Main control |
Maximum |
Vector control: 0~600Hz |
Carrier Frequency |
1k ~ 15kHz; the carrier frequency will be automatically |
|
Input frequency |
Digital setting: 0.01Hz |
|
Control mode |
Open loop vector control ; |
|
Start-up torque |
Mode G machine: 0.5Hz/180% (open loop vector control) |
|
Speed adjustment |
1:200(Open loop Vector flux control) |
|
Main control |
Stable speed |
Open loop Vector flux control:≤±0.5% (rated synchronous |
Stabilization of |
Open loop Vector flux control:≤±0.3% (rated synchronous |
|
Torque response |
≤40ms(Open magnetic flux vector control) |
|
Overload capacity |
Mode G machine: 150% rated current 60s; 180% rated current 5s |
|
Torque boost |
Automatic torque boost; manual torque boost 0.1% to 30.0% |
|
V/F curve |
Linear V/F, Multi-point V/F, and Square V/F |
|
Speed-up and |
Straight line or S curve speed-up and speed-down mode; |
|
Speed-down curve |
Speed-up and speed-down time ranges from 0.0s |
|
DC brake |
DC brake frequency: 0.00Hz ~ maximum frequency; brake time: 0.0s ~ 36.0s, and brake current value: 0.0% to 100.0%. |
|
Jog control |
Jog frequency range: 0.00Hz ~ 50.00Hz; |
|
Simple PLC and |
It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. |
|
Built-in PID |
It is easy to realize process-controlled close loop control system. |
|
(AVR)Automatic |
It can keep constant output voltage automatically in case of change of mains voltage. |
|
Torque limit and |
"Shovel" characteristics, automatic limit on the torque on running time, preventing frequent over-current trip; closed loop vector mode can realize the torque control |
|
Customized functions |
Peripherals |
It can conduct safety detections on the peripherals upon power-on, including earth and short circuit detections. |
Shared DC bus |
It can realize the function that multiple inverters share the DC bus. |
|
JOG key |
Programmable key: Select the forward and reverse rotations/jog operation command. |
|
Traverse frequency |
Multiple triangular-wave frequency control function. |
|
Fast current limit |
With fast current limit algorithm built in to reduce the probability of over-current alarm; to improve the anti-jamming capacity of the whole machine. |
|
Timed control |
Timing control function: Setting time range from 0h to 65535h. |
|
Keyboard extension |
Customers can use standard cable to extend the keyboard |
|
Operation |
Running command |
Three types of channels: operation panel given, control terminal given and serial communication port given. These channels can be switched in various ways. |
Frequency source |
Ten types of frequency sources in total: digital given, analog voltage given, analog current given, pulse given, and serial port given. It can be switched in various ways. |
|
Auxiliary frequency |
Ten types of auxiliary frequency sources in total. It can implement micro tuning and synthesis of auxiliary frequency. |
|
Input terminal |
Seven digital input terminals, and nine terminals in maximum |
|
Output terminal |
One digital output terminal (bipolar output) |
|
Display and Keyboard |
LED display |
Display parameter |
LCD display |
Selective parts, Chinese/English to suggest the operation |
|
LCD Parameter copy |
Use LCD parameter special copy keyboard can copy the |
|
Key lock and |
Lock part of the keyboard or the whole keyboard, definite the |
|
Protection |
protection function |
Short circuit detective of power-on motor, input and output |
Selective accessories |
LCD operation panel, brake group etc. |
|
Environment |
Suitable place |
Indoor environment which is against from direct sunlight, |
Altitude |
Less than 1000m |
|
Ambient |
-10℃ ~ +50℃ (derating is required if the natural temperature |
|
Humidity |
Less than 95%RH, no condensing water drops |
|
Vibration |
Less than 5.9m/ s2 (0.6g) |
|
Storage temperature |
-20℃ ~ +60℃ |
|
Class of pollution |
2 |
VFD Application Industries and Fields
HIVERT Standard medium voltage VFD series is widely used in various fields in national economy, exported to Europe, Middle East, Southeast Asia etc.. Perfect solutions for soft start, speed adjusting, energy saving and intelligent control of medium voltage AC motors (including synchronous and asynchronous motors) could be supplied to customers.
Hiconics is a frequency inverter distributor, we provide single vfd for multiple motors, vfd multiple motors, vfd inverter, etc. Want to know more, contact us.
Buen trato: comprar del vendedor
Esta página es acerca de los importadores y exportadores de 220V/0.4-800kW Construction All-in-one Machine Buscar en la categoria : B2B Servicios Buscar en la categoria : machine, 800kw, 220v, construction |
Lunes 04 marzo 2013
Cantidad : 30 - Precio : $395.00
It's not just phone we're talking about... it's smart phone... it's Samsung GALAXY S III. It has the looks and a symmetry which would make you proud to hold it in your hands. You couldn't ask for more imposing façade than its 4.8 inches HD Super AMOLED high-definition display. It delivers...
Jueves 09 enero 2025
Unitronics Vision130 PLC+HMI OPLC – Automate Control Engineering Ltd. (winston@automate-ace.com) Vision130.Connects! PLC, HMI & onboard I/Os plus ETHERNET, SMS/GPRS, CANopen, MODBUS... The Vision130.is a palm-sized PLC with a built-in Operator Panel. The panel offers a graphic...
Jueves 14 julio 2016
DVP Double Stages Vacuum Transformer Oil Purifier is designed specially for maintaining to maintain optimal insulation properties of the transformer oils by rigid control over moisture, dissolved gases, particulate contamination and acidity. DVP Vacuum Transformer Oil Purifier adopts...