Bienes de equipo
MEWOI5700-Three Phase Digital Phase Volt-Ampere Meter |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The MEWOI5700 Three Phase Digital Phase Volt-Ampere Meter is a well-developed full-automatic, multi-functional, digital, intelligent meter specifically designed for field testing,featuring high accuracy, high stability, low power consumption, easiness to use and so on. It can directly measure AC voltage and AC current without opening the measured circuit, phases between three voltages, three currents and phase between the voltage and current; in addition, the power factor and power of the circuit can be indirectly measured, it can also be used to distinguish three-phase sequence, transformer wiring group, inductive and capacitive circuits, test second circuit and bus differential protection systems, read the phase relationship between CTs of the differential protection, check the meter wiring right, repair lines and equipment, etc. The MEWOI5700 Three Phase Digital Phase Volt-Ampere Meter has well designed shell mould made of newest material, attach with shakeproof, skidproof, high insulation sheath, has a 240dots×160dots LCD screen, all the test data display on the screen simultaneously, vector diagram indication, and looks exquisite and comfortable. Meter equipped with USB-RS232 interface, can store 1500 sets of data, through the system software upload stored data to the computer, implementing online real-time monitoring and historical inquires, dynamic display. Can read, save, report, print history data, etc. The MEWOI5700 Three Phase Digital Phase Volt-Ampere Meter (Intelligent Three Phase Digital Phase Volt-Ampere Meter) applies to electric power, petroleum chemical industry, metallurgy, railway, and meteorology, industrial and mining enterprises, scientific research institutions, measurement sector and so on. Especially for the electricity billing system and relay protection system. |
TECHNICAL SPECIFICTION
1.Base Conditions and Working Conditions
|
Influence Quantity |
Base Condition |
Working Condition |
Remark |
|
Ambient Temperature |
23℃±1℃ |
-10℃~40℃ |
---- |
|
Ambient Humidity |
40%~60% |
<80% |
---- |
|
Signal Waveform |
sine wave |
sine wave |
β=0.01 |
|
Signal Frequency |
50HZ±1HZ |
45HZ~65HZ |
---- |
|
Meter Working Volt |
9V±0.1V |
9V±1.5V |
---- |
|
Current Amplitude in Phase/Frequency/Phase SequenceTest |
1A±0.2A |
2mA~20A |
---- |
|
Voltage Amplitude in Phase / Frequency/ Phase Sequence Test |
100V±20V |
10V~600V |
---- |
|
Current Amplitude in Power / Power Factor Test |
1A±0.1A |
0.1A~400A |
---- |
|
Voltage Amplitude in Power / Power Factor Test |
200V±2V |
30V~600V |
---- |
|
External ElectricMagnetic Field |
To be avoided |
||
|
Measured Wire Position |
Measured wire at approximately the geometric center of the clamp | ||
2.Intrinsic Error and Performance Indicators under Base Conditions
|
Category |
Measurement Range |
Resolution |
Intrinsic Error |
|
Voltage |
AC 0.0V~600V |
0.01V |
±(1.5%rdg+5dgt) |
|
Current |
AC 0mA~400A |
1mA |
±(1.5%rdg+5dgt) |
|
Phase |
0.0°~360° |
0.1° |
±3° |
|
Active Power |
0.0W~240kW |
0.1W |
±(3%rdg+5dgt) |
|
Reactive Power |
0.0VAR~240kVAR |
0.1VAR |
±(3%rdg+5dgt) |
|
Apparent Power |
0.0VA~240kVA |
0.1VA |
±(3%rdg+5dgt) |
|
Frequency |
45HZ~65HZ |
0.01HZ |
±(2%rdg+5dgt) |
|
Power Factor |
-1~+1 |
0.001 |
±0.03
|
APPLICAITON

SELECTION GUIDE
Digital Phase Volt-AMP Meter
Click "Blue"Marked model number to view the Detailed Specification
| Model | Range | Resolution | Clamp Quantity&Size | RS232 | Data Storage |
MEWOI5000B![]() |
AC:0.00 V~600V (automatic shift),AC:0.0mA~20.0A (automatic shift),Phase:0~360°,Active Power:0.0W~12kW | AC 0.01V,AC 0.1mA,Phase:0.1° | 2pc*φ7.5mm | √ | 1500sets |
MEWOI5200B![]() |
AC:0.00 V~600V (automatic shift),AC:0.0mA~20.0A (automatic shift),Phase:0~360°,Active Power:0.0W~12kW | AC 0.01V,AC 0.1mA,Phase:0.1° | 2pc*φ40mm | √ | 1500sets |
MEWOI5300![]() |
AC:0.00 V~600V (automatic shift),AC:0.0mA~20.0A (automatic shift),Phase:0~360°,Active Power:0.0W~12kW | AC 0.01V,AC 0.1mA,Phase:0.1° | 3pc*φ7.5mm | √ | 500sets |
MEWOI5700![]() |
AC:0.00 V~600V (automatic shift),AC:0.0A~400A (automatic shift),Phase:0~360°,Active Power:0.0W~240kW | AC 0.01V,AC 0.1A,Phase:0.1° | 3pc*φ40mm | √ |
500sets |
Buen trato: comprar del vendedor
|
Esta página es acerca de los importadores y exportadores de MEWOI5700-Three Phase Digital Phase Volt-Ampere Meter Buscar en la categoria : Bienes de equipo Buscar en la categoria : three, phase, ampere, meter, mewoi5700, digital, volt |
Tuesday 25 November 2025
Precio : $750.00
Buy «Hangar 9 Pitts S-2B 50-60cc With DLE 60cc Twin Engine» from REALWORLDHOBBY Online Store one of the world's leading online retailers for a wide selection of RC Planes, RC Helicopters, Drones, Cars / Trucks RC, RC Boat, and RC Rock Crawler. Price : $750.00 Payment Options : PayPal...
Wednesday 29 June 2022
Cantidad : 100
8 ports PoE+ avec un budget d'alimentation total de 60 W et inclut la technologie NETGEAR FlexPoE, ce qui la rend extensible à 90 W ou même 130 W (avec des modules d'alimentation achetés séparément). Connectivité Type de port Ethernet RJ-45 de commutation de base Gigabit Ethernet...
Saturday 19 December 2020
Cantidad : 1 - Precio : $ 510
Original Printhead Roland DX7/VS 640 Print Head 6701409010 Printer The Roland RE640 / VS640 DX7 printhead is either used in 4-colour or 8-colour printers and has a minimum, variable droplet size of 1.5 pico litre (max. droplet size is 21 pico litre) Condition: New product Genuine...