Construcción
Glycol Cooling Heating Control System
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Type | KRY-5A25W | ||
| Medium Temp. range | -40℃~100℃ | -45℃~120℃ | |
| Control mode | Feedforward PID+our special dynamic control calculation, PLC controller | ||
| Temp. control | Control ethylene glycol solution temp. | Control inner box temp. | |
| Program editor | 10 programs, each program can edit 45 steps | ||
| Communication protocol | MODBUS RTU protocol, RS 485 interface | ||
| Temp. feedback | Heat-conducting medium: PT100 (oil inlet,oil outlet and heater temp. measure) 3 temp. Measuring points |
single temp.measuring | |
| Temp. accuracy | ±0.5℃ | ±0.3℃ | |
| Heating power | 25kW | 9kW | |
| Cooling capacity | 100℃ | 25kW | 9kW |
| 20℃ | 25kW | 9kW | |
| 0℃ | 25kW | 9kW | |
| -20℃ | 25kW | 9kW | |
| -40℃ | 10kW | 4kW | |
| Internal circulation | 2400m³/h | ||
| wind flow rate | |||
| Circulation pump | Max110L/min 2.5BAR | ||
| Compressor | Dorin | Emerson | |
| Expansion valve | Emerson | ||
| Oil separator | Emerson | ||
| Evaporator | KAORI plate heat exchanger | Copper aluminum-fin | |
| Operation panel | 7-inch touch screen, temperature curve record/excel data output | ||
| Safety protection | Self-diagnosis function; freezer overload protection; high-pressure switch; overload relay; thermal protection device, liquid low-level protection, high-temperature protection and temperature |
||
| Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
||
| Refrigerant | R-404A | ||
| Connection size | DN25 PN10 | ||
| Water-cooled type W | 8.5m³/h 1.5bar~4bar cooling water@25℃ | ||
| Water-cooled condenser | Shell and tube exchanger | ||
| Power | 380V 50HZ 57kw(max) | ||

Maintenance of Glycol Cooling Heating Control System
Apart from the attention needed during the daily use, the regular check and maintenance of Glycol Cooling Heating Control glycol refrigeration system are also very important. In order to help all of you learn to use Glycol cooling heating more efficiently, Guanya Refrigeration sort out related maintenance, so that you can use it in time.
Screw Compressor
Screw compressor is a very important part of ethylene glycol refrigerator, and the compressor is directly related to the stability of the unit. If the compressor has something wrong, In view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so it needs to be paid more attention in the ordinary use process in using.
Condensers and Evaporators
Is there is something wrong with the Glycol cooling heating control system, in view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so the compressor needs to be paid more attention in the ordinary use process.
Washing of condensers and evaporators
The cooling water of the water-cooled condenser of glycol refrigeration unit is open loop circuit. The circulating water is usually used by the cooling tower. When calcium the content of salt and magnesium salt in water is large, it is easy to decompose the fouling between the pipe and rock, and the heat transfers. Once the scale of the condenser of glycol cooling system is too thick, the cross section of the cooling water will decrease, the water volume will decrease and the condensing pressure will increase. Therefore, when the water quality of the cooling water is poor, the cooling water pipe should be washed at least once a year to remove scale and other contaminants. Of course, not only glycol cooling system but other other related cooling equipment used for a period of time, their maintenance knowledge is needed to learn in everyday use.
Buen trato: comprar del vendedor
|
Esta página es acerca de los importadores y exportadores de Glycol Cooling Heating Control System Buscar en la categoria : Construcción Buscar en la categoria : cooling, control, heating, system, glycol |
Tuesday 16 June 2015
Cantidad : 10000m2/we - Precio : USD 80-90/m2
Air slide belt Airslide Belt (pneumatic conveyor belt) has fine breathability, it is used for pneumatic conveyors o f bulk materials. It is an indis pensable part of cement industry, aluminium, lime and gypsum indust ry, coal-fired power stations, transport of bulk goods, chemical industry ...
Tuesday 12 May 2026
Cantidad : 20 Unit - Precio : $802
Price: US $802 Site: azriadi.com Accept Paypal Introducing the most powerful miner available in the market. This 4.9 TH/s mining beast focuses on what matters to you. With amazing hash power and remarkably low power consumption, the SP31 - Yukon offers nearly three times the hashing...
Monday 31 March 2014
Cantidad : ≥200KG - Precio : 5.88 USD/KG~6.98 USD
RTV- 2 de caucho de silicona para la fabricación de moldes Modelo del producto: INNO SILICA ® IS -CR Dureza: 15 Shore A, 20 Shore A, 25 Shore A, 30 Shore A, 35 Shore A, 40 Shore A Aplicaciones: Se utiliza principalmente en la industria de fabricación de moldes con vertido o cepillado...