Glycol Cooling Heating Control System
Application:
The tested object is attached to a test platform adapter.
The inside of the part was cooled and heated by an aqueous solution of ethylene glycol.
The test component needs to undergo a specific temperature profile and record changes in temperature. Temperature variations typically range from -40 to 100 degrees.
When performing a tolerance test, it usually takes an infinite loop.
Antifreeze temperature from -40 degrees to 100 degrees
Very steep temperature gradient change
Export temperature limit
Visualization, data storage, and reporting analysis
Temperature control equipment can be flexibly connected to other test platforms
Equipped with a powerful circulation pump while ensuring the delivery of highly viscous liquids.
Control the flow output with a proportional control valve to achieve high-precision control of the total range 5% to 100% adjustment
Type | KRY-5A25W | ||
Medium Temp. range | -40℃~100℃ | -45℃~120℃ | |
Control mode | Feedforward PID+our special dynamic control calculation, PLC controller | ||
Temp. control | Control ethylene glycol solution temp. | Control inner box temp. | |
Program editor | 10 programs, each program can edit 45 steps | ||
Communication protocol | MODBUS RTU protocol, RS 485 interface | ||
Temp. feedback | Heat-conducting medium: PT100 (oil inlet,oil outlet and heater temp. measure) 3 temp. Measuring points |
single temp.measuring | |
Temp. accuracy | ±0.5℃ | ±0.3℃ | |
Heating power | 25kW | 9kW | |
Cooling capacity | 100℃ | 25kW | 9kW |
20℃ | 25kW | 9kW | |
0℃ | 25kW | 9kW | |
-20℃ | 25kW | 9kW | |
-40℃ | 10kW | 4kW | |
Internal circulation | 2400m³/h | ||
wind flow rate | |||
Circulation pump | Max110L/min 2.5BAR | ||
Compressor | Dorin | Emerson | |
Expansion valve | Emerson | ||
Oil separator | Emerson | ||
Evaporator | KAORI plate heat exchanger | Copper aluminum-fin | |
Operation panel | 7-inch touch screen, temperature curve record/excel data output | ||
Safety protection | Self-diagnosis function; freezer overload protection; high-pressure switch; overload relay; thermal protection device, liquid low-level protection, high-temperature protection and temperature |
||
Closed circulation system | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
||
Refrigerant | R-404A | ||
Connection size | DN25 PN10 | ||
Water-cooled type W | 8.5m³/h 1.5bar~4bar cooling water@25℃ | ||
Water-cooled condenser | Shell and tube exchanger | ||
Power | 380V 50HZ 57kw(max) |
Maintenance of Glycol Cooling Heating Control System
Apart from the attention needed during the daily use, the regular check and maintenance of Glycol Cooling Heating Control glycol refrigeration system are also very important. In order to help all of you learn to use Glycol cooling heating more efficiently, Guanya Refrigeration sort out related maintenance, so that you can use it in time.
Screw Compressor
Screw compressor is a very important part of ethylene glycol refrigerator, and the compressor is directly related to the stability of the unit. If the compressor has something wrong, In view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so it needs to be paid more attention in the ordinary use process in using.
Condensers and Evaporators
Is there is something wrong with the Glycol cooling heating control system, in view of the high precision of the assembly precision of the screw compressor, the factory is usually required to carry out the maintenance, so the compressor needs to be paid more attention in the ordinary use process.
Washing of condensers and evaporators
The cooling water of the water-cooled condenser of glycol refrigeration unit is open loop circuit. The circulating water is usually used by the cooling tower. When calcium the content of salt and magnesium salt in water is large, it is easy to decompose the fouling between the pipe and rock, and the heat transfers. Once the scale of the condenser of glycol cooling system is too thick, the cross section of the cooling water will decrease, the water volume will decrease and the condensing pressure will increase. Therefore, when the water quality of the cooling water is poor, the cooling water pipe should be washed at least once a year to remove scale and other contaminants. Of course, not only glycol cooling system but other other related cooling equipment used for a period of time, their maintenance knowledge is needed to learn in everyday use.
Persona a contactar : Tony Tony, 0510 82303782
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de Glycol Cooling Heating Control System Buscar en la categoria : Construcción Buscar en la categoria : control, glycol, cooling, system, heating |
Miércoles 23 marzo 2016
12 balls package £1,900.00 Guarantee: We test each ball for to ensure the ball seamed exactly well. Delivery time: arrive within 14 days after payment Logo printing: free Warranty: 1 year quality guarantee and free repair kit. About PVC/TPU inflatable body zorb ball : Q: What is...
zorbingfootball
- NW61HS - London
- 720 316 2788
Jueves 27 marzo 2014
Precio : €1.35
Caractéristiques: - Bon pour l'environnement - Sans mercure - très efficace - Extrêmement durable - Convient pour des applications intelligentes - Chaleur rayonnée minimale Note: La quantité d'acheter au minimum est 1 boîte( 6 ou 12 pièces). SKU Enballage Lumen Puissance...
WELL MOUNT N.V.
- 2160 - Wommelgem
- 32 33551988
Martes 29 octubre 2013
Cantidad : 1 - Precio : 450 000
Vends d'occasion: 1 ligne complète pour fabriquer des granulés de bois (pellet) et buches de bois densifié. Production : 3 Tonnes Heure. - Marque Klöckner - Matériel à travailler 3 ans est en parfait état. - Matériel encore installé. 1- Arrivée de la matière première soit en...
![Pago seguro](https://es.algomtl.com/images/side_paiement.jpg)