CTnI test kit (FIA) CE Marked

Product Name
Troponin I (cTnI) Test Kit (Immunofluorescence Chromatography)

Purpose
To detect the cTnI in human plasma/serum/whole blood in vitro quantitatively.For Professional Use only.

Principles of Detection
The cTnI Test is a fluorescent lateral flow immunoassay. The test consists of: 1) a conjugate pad containing cTnI antibody conjugated with fluorescent microspheres and a control antibody (goat anti-chicken IgY antibody) conjugated with fluorescence microspheres, 2) a nitrocellulose membrane strip containing a test line (T line) and a control line (C line). The T line is pre-coated with another cTnI antibody, and the C line is pre-coated with a control line antibody (chicken IgY antibody).
cTnI concentration in specimen is positively correlated with the fluorescent density of the microspheres, after the measure and calculation of the quantitative fluorescence immunoassay analyzer, then the analyzer would calculate the concentration of cTnI according to the preset calibration curve in the machine and display the result, detection unit is ng/mL. C line should appear in any cases, which indicates the reaction system is effective.

Storage conditions and shelf life
Store in a sealed aluminum foil bag at 2~30°C. After unpacking the aluminum foil bag under temperature 20~30 ºC , humidity 35~65%, please use it immediately.
Shelf life 18 months.

Applicable instrument
Avid fluorescent immunoanalyzer model: AI-IF 600

Reference range
The 95th percentile of the serum and plasma samples of 200 normal persons is <0.3ng/mL.;<br /> The reference value is verified by referring to similar products on the market. Due to ethnic and regional differences, each laboratory can establish its own reference interval according to the actual situation.

Performance Characteristics
1. Linear range
In the range of 0.1ng/mL ~40ng/mL, the r value should be ≥0.990.
2. Accuracy
Detected with the enterprise internal control accuracy reference (C1, C2), the test results should be within the following ranges.
(1) Detection with the enterprise internal control accuracy reference C1, the instrument measurement range is 0.5ng/mL ±15% at 15 minutes.
(2) Detection with the enterprise internal control accuracy reference C2, the instrument measurement range is 5ng/mL ±15% at 15 minutes..
3. Intra-batch precision
Using the enterprise internal control precision reference (C9, C10) each parallel test 10 times, at 15 minutes instrumentation, the concentration value coefficient of variation CV≤15%.
4.Inter-batch precision
For three batches of reagent kits, 10 times of parallel testing with each enterprise internal control precision reference (C9, C10), and the instrument measurement at 15 minutes, the concentration coefficient of variation CV≤15%.
5.Detection limit
Detection with the enterprise internal control of the detection limit reference L1, instrumentation at 15 minutes, the results should be ≤0.1ng/mL.
6.Specificity
Detection with the enterprise internal control specificity reference (C3, C4, C5), the instrument measurement value at 15 minutes should be less than 0.1ng/mL.

Ubicación : C501, Bui Iding B5, China Merchants Guangming Science Park,#3009 Guanguang Road,Guangming District, Shenzhen, 518132 Shenzhen,
Persona a contactar : Yang Shawn, +8618543132823

ShawnYang

  • 3.6/5
Detalle
Inscrito el 29 marzo 2022

Identificación de la empresa : Shenzhen Aivd Biotec

Sitio web : www.aivdbiotech.com

Enviar un correo electrónico a ShawnYang

ShawnYang

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
CTnI test kit (FIA) CE Marked

Buscar en la categoria : Medicina
Buscar en la categoria :
marked, test, ctni
  • 3.7/5
  • 1
  • 2
  • 3
  • 4
  • 5
Taiwán 414 Bienes de equipo

Reportar abuso

Jawo Sheng - Embossing Machine
Jawo Sheng - Embossing Machine

Friday 13 November 2015

Jawo Sheng Precise Machinery Works Co., Ltd. Founded in 1978, JS have manufactured embossing machine, varnishing machine, flexo printing machine, flexographic printing machine and packaging printing machine over years. Therefore, we have been at the forefront of the industry for...

Jawo Sheng Precise Machinery Works Co., Ltd.

  • Sj1978
  • 414 - Taichung
  • +886 4 2335 8268
  • +886423358268
  • 3.8/5
  • 1
  • 2
  • 3
  • 4
  • 5
Hong Kong 523929 Higiene / salud

Reportar abuso

Foto no disponible
Air Purifier

Friday 21 August 2015

Air Purifier RM-AC600 Certification: ISO9001 2 year warranty Key Specification 1.Color: Various color can be chosed 2.Input Voltage: 110~240V 3.Rated Power: 50-60HZ 4.Power(W) : 36~55W 5.Noise Level: 25~55dB 6.Display Mode: LED 7.Control Mode: Touch screen 8.CADR: 450m³/H 9...

Rooman Electrical Appliances Co., Ltd.

  • Rooman1
  • 523929 - Dongguan
  • +13 6 62 88 32 70
  • 2.4/5
  • 1
  • 2
  • 3
  • 4
  • 5
Taiwán 80673 Audio / video

Reportar abuso

PICOTEST P9610A (108W/36V/7A) Linear & Switching DC Power Supply - Better than Agilent...
PICOTEST P9610A (108W/36V/7A) Linear & Switching DC Power Supply - Better than Agilent...

Wednesday 26 November 2014

Cantidad : 1 piece - Precio : USD 735

We're glad to inform you that Picotest's mixed mode (Linear + Switch) DC power supplies, P9610A (108W/36V/7A) are ready. We need you to put them on the sales line. In the first beginning, P9610A is designed to beat Agilent E3632A (End User Price: USD 1100~1200). However, its autoranging...

PICOTEST CORP.

  • n800097
  • 80673 - Kaoshiung
  • 886 7 815 7183 ext : 806
  • 886 920 032 030