Informática
AKH-0.66 / K Split Core Current Transformer |
|
Type |
W |
H |
D |
a |
e |
Primary Input(A) |
Net Weight(kg) |
|
K-30×20 |
90 |
114 |
40 |
22 |
32 |
20-400 |
0.8-0.9 |
|
K-60×40 |
114 |
140 |
36 |
42 |
62 |
250-2000 |
1.0-2.0 |
|
K-80×40 |
122 |
162 |
40 |
42 |
82 |
300-3000 |
1.2-2.4 |
|
K-80×50 |
114 |
159 |
36 |
52 |
82 |
250-1000 |
1.1-1.4 |
|
K-80×80 |
144 |
159 |
36 |
82 |
82 |
250-1000 |
1.3-1.5 |
|
K-120×80 |
144 |
199 |
36 |
82 |
122 |
500-1500 |
1.5-2.3 |
|
K-120×60 |
164 |
214 |
52 |
62 |
122 |
400-5000 |
1.6-3.0 |
|
K-100×40 |
144 |
194 |
A |
42 |
102 |
1000-5000 |
1.6-3.2 |
|
K-130×40 |
144 |
224 |
52 |
42 |
132 |
1000-5000 |
1.6-3.6 |
|
K-140×60 |
164 |
234 |
52 |
62 |
142 |
1000-5000 |
1.7-3.7 |
|
K-160×80 |
184 |
254 |
52 |
82 |
162 |
1000-5000 |
2.8-3.7 |
|
K-200×80 |
184 |
294 |
52 |
82 |
202 |
1000-5000 |
3.5-4.5 |
|
Type |
Ratio(A) |
Class |
Burden(VA) |
|
K-30x20 |
20-75/1 |
1 |
0.2 |
|
100-150/5(1) |
1 |
1 |
|
|
200/5(1) |
1 |
1.5 |
|
|
250-300/5(1) |
0.5 |
1.5 |
|
|
350-400/5(1) |
0.5 |
2.5 |
|
|
K-60x40 |
250-300/5(1) |
1 |
1.5 |
|
350-400/5(1) |
0.5 |
1.5 |
|
|
500-800/5(1) |
0.5 |
2.5 |
|
|
1000-1250/5(1) |
0.5 |
5 |
|
|
1500-2000/5(1) |
0.5 |
10 |
|
|
K-80x40 |
350/5(1) |
1 |
1.5 |
|
350-450/5(1) |
0.5 |
2.5 |
|
|
500-800/5(1) |
0.5 |
5 |
|
|
1000-2000/5(1) |
0.5 |
10 |
|
|
2500-3000/5(1) |
0.2 |
10 |
|
|
K-80x50 |
250-300/5(1) |
1 |
1.5 |
|
400-450/5(1) |
0.5 |
1.5 |
|
|
500-800/5(1) |
0.5 |
2.5 |
|
|
1000/5(1) |
0.5 |
5 |
|
|
K-80x80 |
250-300/5(1) |
1 |
1.5 |
|
400-450/5(1) |
0.5 |
1.5 |
|
|
500-800/5(1) |
0.5 |
2.5 |
|
|
1000/5(1) |
0.5 |
5 |
|
|
K-100x40 |
1000-2000/5(1) |
0.5 |
10 |
|
2500-3000/5(1) |
0.2 |
10 |
|
|
4000-5000/5(1) |
0.2 |
15 |
|
|
K-120x60 |
400-450/5(1) |
0.5 |
2.5 |
|
500-800/5(1) |
0.5 |
5 |
|
|
1000-2000/5(1) |
0.5 |
10 |
|
|
2500-5000/5(1) |
0.2 |
10 |
|
|
K-120x80 |
500-800/5(1) |
0.5 |
2.5 |
|
1000-1200/5(1) |
0.5 |
5 |
|
|
1250-1500/5(1) |
0.5 |
7.5 |
|
|
K-130x40 |
1000-2000/5(1) |
0.5 |
10 |
|
2500-5000/5(1) |
0.2 |
10 |
|
|
K-130x60 |
1000-2000/5(1) |
0.5 |
10 |
|
2500-6000/5(1) |
0.2 |
15 |
|
|
K-140x60 |
1000-2000/5(1) |
0.5 |
10 |
|
2500-3000/5(1) |
0.2 |
10 |
|
|
4000-5000/5(1) |
0.2 |
15 |
|
|
K-160x80 |
1000-2000/5(1) |
0.5 |
10 |
|
2500-3000/5(1) |
0.2 |
10 |
|
|
4000-5000/5(1) |
0.2 |
15 |
|
|
K-200x80 |
1000-2000/5(1) |
0.5 |
10 |
|
2500-3000/5(1) |
0.2 |
10 |
|
|
4000-5000/5(1) |
0.2 |
15 |
|
|
K-Φ20 |
100A/20mA |
1 |
15Ω |
|
K-Φ30 |
200A/20mA |
0.5 |
10Ω |
|
K-Φ30 |
300A/20mA |
0.5 |
10Ω |
AKH-0.66/K Series Split Type Current Transformer Diagram
Hold the lower section firmly at the direction of arrow
Loosen two screws at the direction of arrow and remove them
Separate the lower section at the direction of arrow
Mount the copper bar and assemble the lower section at the direction of arrow
Hold it firmly at the direction of arrow
Hold the lower section firmly at the direction arrow, insert two screws and tighten nuts
Fix the copperbar with M5screwsand pressure plates
Acrel AKH-0.66/K Series SCT Current Transformers Uses
Our flexible split core current transformers are effectively used in reconstructing projects of urban
Split core current transformers are suitable for rural power grids to reconstruct
Split Core Current Transformer Installation
Press the arrow direction firmly to open the two screws and press the lower part
Unscrew and pull out the two screws in the direction of the arrow, see "P2"
Pull the screw and pull out the lower part in the direction of the arrow
After installing on the copper busbar, close the lower part in the direction of the arrow, see "P4"
Press firmly in the direction of the arrow
Press the lower part firmly and press the arrow direction to insert the two screws into the holes and tighten the screw width, see "P6"
Then use MS screws and pressure plate to install and press the steel row according to "P6"
Buen trato: comprar del vendedor
|
Esta página es acerca de los importadores y exportadores de AKH-0.66 / K Split Core Current Transformer Buscar en la categoria : Informática Buscar en la categoria : core, split, transformer, current |
Wednesday 22 April 2015
Cantidad : 10PCS - Precio : USD3250
Power: 150W Meanwell Gan serie Power Drive + original brigelux LED 45 mm, cinco años de protección También podemos suministrar 150W 200W 80W 60W 30W Iluminación: el ángulo de 90 grados Voltaje de entrada: AC100 - 277V El brillo del LED de atenuacion: <</span> 5% / 6000...
Friday 16 May 2014
Cantidad : 5000sets - Precio : $1000-5000/set
Descripción: 1.Base del molde: hasco, dme, rabudin lkm, din, jis. molde 2.Núcleo: 718, s136, p20, nak, lkm, ek 4, x13t6w etc. canal Caliente 3.Molde- maestría punta, maestro, husky, hasco, dme, thermoplay yudo, incoe,etc. 4. Piezas estándar: dme, hasco, más cercano estándar ansi...