AKH-0.66 / K Split Core Current Transformer
Cantidad : 10000piece Precio : 5-500USD/piece
Acrel AKH-0.66/K series split core current transformer are mainly used in reconstructing projects of urban and rural power grids. The split core current sensors can be mounted easily without the removal of the primary bus. They also can be operated with electricity, which prevents the normal utilization of electricity.
Acrel AKH-0.66/K SCT current transformers series save manpower, material resources, and financial resources and improve the efficiency of users. This current transformer split core matches with relay protection, measuring, and metering equipment.
Without removal of primary bus
Be operated with electricity
Save manpower
Varies dimension optional
AKH-0.66/K Split Core Type Current Transformers Parameters
Type |
W |
H |
D |
a |
e |
Primary Input(A) |
Net Weight(kg) |
K-30×20 |
90 |
114 |
40 |
22 |
32 |
20-400 |
0.8-0.9 |
K-60×40 |
114 |
140 |
36 |
42 |
62 |
250-2000 |
1.0-2.0 |
K-80×40 |
122 |
162 |
40 |
42 |
82 |
300-3000 |
1.2-2.4 |
K-80×50 |
114 |
159 |
36 |
52 |
82 |
250-1000 |
1.1-1.4 |
K-80×80 |
144 |
159 |
36 |
82 |
82 |
250-1000 |
1.3-1.5 |
K-120×80 |
144 |
199 |
36 |
82 |
122 |
500-1500 |
1.5-2.3 |
K-120×60 |
164 |
214 |
52 |
62 |
122 |
400-5000 |
1.6-3.0 |
K-100×40 |
144 |
194 |
A |
42 |
102 |
1000-5000 |
1.6-3.2 |
K-130×40 |
144 |
224 |
52 |
42 |
132 |
1000-5000 |
1.6-3.6 |
K-140×60 |
164 |
234 |
52 |
62 |
142 |
1000-5000 |
1.7-3.7 |
K-160×80 |
184 |
254 |
52 |
82 |
162 |
1000-5000 |
2.8-3.7 |
K-200×80 |
184 |
294 |
52 |
82 |
202 |
1000-5000 |
3.5-4.5 |
Type |
Ratio(A) |
Class |
Burden(VA) |
K-30x20 |
20-75/1 |
1 |
0.2 |
100-150/5(1) |
1 |
1 |
|
200/5(1) |
1 |
1.5 |
|
250-300/5(1) |
0.5 |
1.5 |
|
350-400/5(1) |
0.5 |
2.5 |
|
K-60x40 |
250-300/5(1) |
1 |
1.5 |
350-400/5(1) |
0.5 |
1.5 |
|
500-800/5(1) |
0.5 |
2.5 |
|
1000-1250/5(1) |
0.5 |
5 |
|
1500-2000/5(1) |
0.5 |
10 |
|
K-80x40 |
350/5(1) |
1 |
1.5 |
350-450/5(1) |
0.5 |
2.5 |
|
500-800/5(1) |
0.5 |
5 |
|
1000-2000/5(1) |
0.5 |
10 |
|
2500-3000/5(1) |
0.2 |
10 |
|
K-80x50 |
250-300/5(1) |
1 |
1.5 |
400-450/5(1) |
0.5 |
1.5 |
|
500-800/5(1) |
0.5 |
2.5 |
|
1000/5(1) |
0.5 |
5 |
|
K-80x80 |
250-300/5(1) |
1 |
1.5 |
400-450/5(1) |
0.5 |
1.5 |
|
500-800/5(1) |
0.5 |
2.5 |
|
1000/5(1) |
0.5 |
5 |
|
K-100x40 |
1000-2000/5(1) |
0.5 |
10 |
2500-3000/5(1) |
0.2 |
10 |
|
4000-5000/5(1) |
0.2 |
15 |
|
K-120x60 |
400-450/5(1) |
0.5 |
2.5 |
500-800/5(1) |
0.5 |
5 |
|
1000-2000/5(1) |
0.5 |
10 |
|
2500-5000/5(1) |
0.2 |
10 |
|
K-120x80 |
500-800/5(1) |
0.5 |
2.5 |
1000-1200/5(1) |
0.5 |
5 |
|
1250-1500/5(1) |
0.5 |
7.5 |
|
K-130x40 |
1000-2000/5(1) |
0.5 |
10 |
2500-5000/5(1) |
0.2 |
10 |
|
K-130x60 |
1000-2000/5(1) |
0.5 |
10 |
2500-6000/5(1) |
0.2 |
15 |
|
K-140x60 |
1000-2000/5(1) |
0.5 |
10 |
2500-3000/5(1) |
0.2 |
10 |
|
4000-5000/5(1) |
0.2 |
15 |
|
K-160x80 |
1000-2000/5(1) |
0.5 |
10 |
2500-3000/5(1) |
0.2 |
10 |
|
4000-5000/5(1) |
0.2 |
15 |
|
K-200x80 |
1000-2000/5(1) |
0.5 |
10 |
2500-3000/5(1) |
0.2 |
10 |
|
4000-5000/5(1) |
0.2 |
15 |
|
K-Φ20 |
100A/20mA |
1 |
15Ω |
K-Φ30 |
200A/20mA |
0.5 |
10Ω |
K-Φ30 |
300A/20mA |
0.5 |
10Ω |
AKH-0.66/K Series Split Type Current Transformer Diagram
Hold the lower section firmly at the direction of arrow
Loosen two screws at the direction of arrow and remove them
Separate the lower section at the direction of arrow
Mount the copper bar and assemble the lower section at the direction of arrow
Hold it firmly at the direction of arrow
Hold the lower section firmly at the direction arrow, insert two screws and tighten nuts
Fix the copperbar with M5screwsand pressure plates
Acrel AKH-0.66/K Series SCT Current Transformers Uses
Our flexible split core current transformers are effectively used in reconstructing projects of urban
Split core current transformers are suitable for rural power grids to reconstruct
Split Core Current Transformer Installation
Press the arrow direction firmly to open the two screws and press the lower part
Unscrew and pull out the two screws in the direction of the arrow, see "P2"
Pull the screw and pull out the lower part in the direction of the arrow
After installing on the copper busbar, close the lower part in the direction of the arrow, see "P4"
Press firmly in the direction of the arrow
Press the lower part firmly and press the arrow direction to insert the two screws into the holes and tighten the screw width, see "P6"
Then use MS screws and pressure plate to install and press the steel row according to "P6"
Persona a contactar : Tim MA, 86 510 86179966
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de AKH-0.66 / K Split Core Current Transformer Buscar en la categoria : Informática Buscar en la categoria : split, current, transformer, core |
Miércoles 07 enero 2015
DESTOCKAGE DE MATERIEL DE RESTAURATION PLAQUE A SNACKER ELECTRIQUE. Plaque en acier lisse poli épaisseur 12mm. Themostat réglable de 50° a 300° C . Bac amovible de récupération des graisses . Puissance 3 Kw 230volts nous disposons aussi: plancha avec 2 thermostat: 390 € plancha...
msi trading
- 95240 - cormeille en parisis
- +33 6 62 72 88 46
Martes 23 abril 2024
Cantidad : 80000 Ream - Precio : $0.79/Ream for 8000
CARACTERÍSTICAS Y BENEFICIOS - Perfecto para impresión de alta calidad y la copia - Super alta blancura produce una claridad excepcional y el contraste para todos los gráficos y texto - Diseño de la caja fácil de usar con asa integrada para facilitar su transporte, perforación...
NATH LAOH LTD
- 50100 - Chiang Mai
- +66 9 95 35 59 56
Jueves 25 abril 2024
Cantidad : 200000
Ubicación : 360 avenue des bigos 34740 vendargues, 34740 vendargues, Persona a contactar : stephane gelly, 06 51 87 22 64
FRIPE'IN
- fripein123
- 34740 - vendargues
- 06 51 87 22 64
- 651872264