PHASE - 2609 Anuncios

Marruecos 9006 Materias primeras
Café Verde Robusta

Martes 14 abril 2020

Cantidad : 18 - Precio : 1 300,00 €

Venta de 1 Contenedor de 20' de Café Verde Robusta de Angola grado BB. El café Robusta de Angola es famoso en el mercado internacional, brindando una bebida neutral y agradable, sin mostrar el sabor penetrante típico de Robusta. Se utiliza en mezclas con café arábica, dando a la mezcla...

BD Network SARL

  • 9006 - Tanger
  • +212631012855
China 710077 Bienes de equipo
Selection Of Proper Models And Introduction Of C18 HPLC Column

Miércoles 08 abril 2020

Importance of Proper Models of HPLC Column In practical application, proper models of the HPLC column have a great influence on the performance or operation of the HPLC column. Improper models could greatly reduce the filtration effect. The HPLC column of high purity silica gel matrix...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
Property And Principle Of Reversed Phase C4 HPLC Column

Miércoles 01 abril 2020

The properties of the reversed-phase filler are determined by the matrix and the substrate. the particle shape, size, pore size and pore size distribution of the matrix, specific surface area, residual silicon hydroxyl concentration, and the content of impurity ions will all have...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
The Basic Operational Steps Of SPE Cartridges

Martes 31 marzo 2020

SPE technology is a physical extraction process including liquid phase and solid phase based on the theory of liquid-solid chromatography, which uses selective adsorption, selective elution to enrich, separate and purify the sample. In daily application, SPE cartridge can also be...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
About Some Question And Answer For QuEChERS

Lunes 30 marzo 2020

1. Why does the QuEChERS approach recommend use dry ice or liquid nitrogen homogenizing frozen samples and extracting samples while frozen? The frozen samples were homogenized with dry ice or liquid nitrogen, and the samples were made into a fine powder (smaller particle size, more homogeneous)...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
Magic Gas-Liquid Separation Flash Column

Miércoles 25 marzo 2020

PureFlash series: silica gel construction and phase column. For example, C18(spherical inlet and irregular home-made), C4, C8, NH2, CN, HILIC, and oxide which are all imported fillers, corresponding to the high-end market. DepuFlash series: silicone construction and phase columns...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
Instruction And Character Of Syringe Filter

Miércoles 25 marzo 2020

Character of syringe filter 1. The PTFE membrane of the syringe filter is completely made of natural and permanent hydrophobic PTFE material. Even under a very low pressure difference, it can ensure that moist air or other gases can pass without hindrance, while the aqueous solution...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
Solutions For High Pressure And Baseline Drift In HPLC Columns

Martes 24 marzo 2020

Remove the column outlet end If the pressure does not drop, the HPLC column is blocked. Treatment: if the buffer salt is blocked, flush 95% water to normal pressure. If some strongly retained substances cause blockage, the mobile phase stronger than the current one should be used...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
An Introduction Of SPE And Method For Selecting SPE Cartridge

Martes 24 marzo 2020

The capacity of the SPE cartridge refers to the adsorption amount of the column packing. For silica-based solid-phase extraction columns, the capacity is generally 1 to 5 mg/100 mg, which means that the column capacity is 1% to 5% of the mass of the packing. The capacity of the bonded...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 215233 Bienes de equipo
Villa Elevator

Jueves 19 marzo 2020

Cantidad : 10000 unit - Precio : USD 9500

SAIL Elevator is an professional house lift manufacturer offers well designed and manufactured house lifts for sale. Home passenger lifts provide passengers with convenience, which gives people a higher level of quality of life. SAIL is a very experienced house lift manufacturer and...

sail intelligent elevator (suzhou) co ltd

  • 215233 - zhen ze town
  • 0086 17851505401
  • +17 8 51 50 54 01
China 710077 Bienes de equipo
The Principle Of Flash Column

Miércoles 18 marzo 2020

Flash column is usually used for the chromatography experiment to separate the complicated compounds by pressurizing air. The hot air enters the stirring, crushing and drying chamber from the bottom of the dryer at a suitable spraying speed from the inlet pipe, which produces strong...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
Precautions On Installation And Maintenance Of Syringe Filter

Miércoles 18 marzo 2020

Widely used to remove particles from a liquid sample and avoid damage to equipment at the same time, syringe filter is affordable tool in the labs, which the scientists can use for small-volume filtration. You can find two different types of filters, one is with which you can recover your sample...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
HPLC Column Requirements For Mobile

Martes 17 marzo 2020

Cleaning and storage of HPLC column Have a good understanding of the sample made, and wash it with the mobile phase that has the strongest eluting capacity for the sample. For silica gel HPLC column, first wash away the polar impurities with methanol, then use dry dichloromethane...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
How To Choose The Right Liquid Chromatography Column, SPE, FALSH, Or HPLC?

Martes 17 marzo 2020

How to understand the chromatographic separation? Put it in short, the more similar the separated substance to the stationary phase, the longer the residence time on it. In this way, different substances in a complex mixed solution can be separated according to time, and the separated...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 B2B Servicios
Molcreator — Your Chemical Synthesis Expert

Sábado 14 marzo 2020

- Welcome to Hawach Scientific Co., Ltd! - Preparing to launch a new project or enter a new market? With Hawach's custom synthesis services, you are not alone. As one of the chemical manufacturing companies, we specialize in implementing your exclusive project. From chemical design...

Molcreator Hawach

  • 710077 - Xi'an
  • 8615102918133
  • 89284425
China 710077 Bienes de equipo
Basic Knowledge Of HPLC Column

Martes 10 marzo 2020

Types of HAWACH HPLC Column There are 2 kinds of HAWACH HPLC columns: Xcheoma series: with many types of fixed phase; with complete varieties and high quality. C18-Aqueous; C18-universal;C18-low pH; C18-Alkaline; C8-universal; C8-Low pH; C8-Fluorine; C4; C30; C1;Phenyl; PAH; etc Echroma series...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
About The SPE Cartridge Packing Type And Features

Martes 10 marzo 2020

1.Mixed-mode cation exchange r: A mixed adsorbent having strong cation exchange and reverse retention, which is highly selective for alkaline analytes, stable in organic solvents. 2.Weak cation exchanger: Weak cation exchange and reverse retention complex mechanism, which is used...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 101116 Bienes de equipo
PCB production Printed circuit board Chemical etching machine

Viernes 06 marzo 2020

Cantidad : 1 - Precio : USD 13000-16000

- Details Images - - Products Description - Dimension: 7820mm×2300mm×2000mm Working height: 900mm±25mm Working width: 650mm Wheel base: 28mm 35mm 48mm 70mm Working speed: 2m/mm(preset working speed) Supply voltage: Three phase four wire,380V/50Hz Total power: 41KW...

EVEREST PCB EQUIPMENT CO.,LTD

China 518055 B2B Servicios
Brushless Motor

Jueves 05 marzo 2020

Brushless DC electric motor (BLDC motors, BL motors) also known as electronically commutated motors (ECMs, EC motors), or synchronous DC motors, are sensored brushless motor powered by DC electricity via an inverter or switching power supply which produces an AC electric current to...

Shenzhen TitanFlying Technology Co., Ltd

  • 518055 - Shenzhen
  • +75 5 21 53 90 34
China 710077 Bienes de equipo
Knowledge Of Headspace Vial

Miércoles 22 enero 2020

The sealing property of the headspace vial is better than that of the threaded vial, and the rubber or silica gel has good re-sealing after the puncture, so it is ideal to preserve the reagents. If some of the organic solvents in use will corrode the silicone or rubber bottle pad...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
How To Select The FLASH Purification Column – Stationary Phase

Martes 21 enero 2020

The FLASH column is the heart of the FLASH purification system, like an engine in a car. If you want to do a good job, you must first sharpen the tools. Choosing the correct FLASH purification column is the most critical part of the whole purification process. And choosing the right...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
How To Operate When The SPE Cartridge Activates The Adsorbent?

Lunes 20 enero 2020

As we know, five steps required for solid phase extraction cartridge: sample preparation, activation or equilibration of the column, loading, rinsing and eluting the compound of interest. There is no uniform regulation for that the solid phase extraction cartridge should be activated...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
Characteristics Of Several Commonly Used Membrane Filters

Lunes 20 enero 2020

1. Nylon Features: good temperature resistance, can withstand 121°C saturation steam hot pressure disinfection for 30min, the highest operating temperature of 60°C, good chemical stability, can withstand dilute acid, dilute base, , ester, oil, hydrocarbons, halogenated hydrocarbons...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
About The Reason And Solution Of The HPLC FAQs

Lunes 20 enero 2020

1. Why does the retention time sometimes drift and sometimes change rapidly when analyzed by HPLC? How to solve it? About drift ① The temperature control is not good. The solution is to use a constant temperature device to keep the HPLC column temperature constant. ② The mobile phase...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
About HAWACH Extraction Kit And Purification Kit For QuEChERS

Domingo 19 enero 2020

The QuEChERS method is a sample preparation technology based on solid-phase extraction and matrix solid-phase dispersion technology. It is suitable for the treatment of low-fat samples and can achieve ideal results for samples containing less than 15% fat. Because of its simple operation...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 201600 Bienes de equipo
Single Shaft Paddle Mixer Machine

Jueves 16 enero 2020

Cantidad : 30 sets/mo - Precio : 1500USD-30500USD

The structure of the single shaft paddle mixer machine is firm and stable. The mixing paddle and material contact is made of stainless steel. Single shaft paddle agitator mixer has good corrosion resistance and keeps the quality and cleanness of the material without discoloration...

Shanghai Niel Machinery Manufacturing Co.,Ltd

  • 201600 - Shanghai
  • 021 57899186
China 710077 Bienes de equipo
The Character Of Hawach Flash Column

Jueves 16 enero 2020

Highlights of HAWACH flash column HAWACH flash column is packed with proprietary technology for automatic packing. The column bed is compact and uniform, has no “ditch flow effect”, with high resolution and good reproducibility. Different particle sizes of normal phase and reversed-phase...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
Why Does Baseline Drift Appear In HPLC Column?

Martes 14 enero 2020

The sample shall be dissolved as much as possible in solvents that are mutually soluble with the mobile phase. Except for special designation, the resolution of the sample HPLC column may be reduced if it is dissolved using a strong solvent. Besides, the sample solution shall be pre-filtered...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
HAWACH QuEChERS Products Classification

Lunes 13 enero 2020

The dispersed solid phase extraction kit is selected based on the type of food being analyzed and the method used. In this step, the extracted sample is added in equal amounts to a 2 ml or 15 ml centrifuge tube. The centrifuge tube contains a small amount of solid phase extraction...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
China 710077 Bienes de equipo
A Brief Introduction Of Three Kinds Of Extraction Thimble

Viernes 10 enero 2020

The extraction thimbles are made of selected high-quality material, using highly efficient and innovative technology and highly homogenized molds. It contains no impurities and the product pore size is uniform. It is often used for Soxhlet extraction and rapid solvent extraction,...

Hawach Scientific Co.,Ltd.

  • 710077 - Xi'an
  • +86 29 89284429
  • +15 1 02 91 81 33
Nombre de resultados por pàgina : 6 30 150

Búsqueda PHASE