China Medicina
Medicina

ACPS Anterior Cervical Plates

ACPS Anterior Cervical Plates

▶▶ Size Information

Code

Names

Specification

243220423

ACPSII 4x23

4holes

243220425

ACPSII 4x25

4holes

243220428

ACPSII 4x27.5

4holes

243220430

ACPSII 4x30

4holes

243220638

ACPSII 6x37.5

6holes

243220640

ACPSII 6x40

6holes

243220643

ACPSII 6x42.5

6holes

243220645

ACPSII 6x45

6holes

243220648

ACPSII 6x47.5

6holes

243220650

ACPSII 6x50

6holes

243220853

ACPSII 8x52.5

8holes

243220855

ACPSII 8x55

8holes

243220858

ACPSII 8x57.5

8holes

243220860

ACPSII 8x60

8holes

243220863

ACPSII 8x62.5

8holes

243220865

ACPSII 8x65

8holes

243220868

ACPSII 8x67.5

8holes

243220870

ACPSII 8x70

8holes

341014012

Fixed angle screw

φ4.0x12

341014014

Fixed angle screw

φ4.0x14

341014016

Fixed angle screw

φ4.0x16

341044018

Adjustable angle screw

φ4.0x18

341044512

Adjustable angle screw

φ4.5x12

341044514

Adjustable angle screw

φ4.5x14

341044516

Adjustable angle screw

φ4.5x16

341044518

Adjustable angle screw

φ4.5x18

▶▶ Indications

A cervical plate is a medically designed implant used during spinal instrumentation and fusion procedures to provide neck stability. Cervical plates enhance the rate of fusion and, in some cases, may reduce the need for external bracing following surgery.

Indications for surgery include intractable pain, progressive neurologic deficits, and documented compression of nerve roots or of the spinal cord that leads to progressive symptoms. Surgery has not been proven to help neck pain and/or suboccipital pain.

▶▶ Products Advantages

Anterior Cervical Plate

● Center line alignment groove design

● Large bone graft window for easy observation of bone graft

● Pre-curved steel plate, in line with the physiological curve of the cervical spine

● Low-cut edge design, thickness 2.2mm

Anterior Cervical Screw

● Self-tapping screws to reduce the use of wire taps

● Distinguish screws by color, quickly distinguish diameter and type

● Fixed angle screws and adjustable angle screws are used together for different indications

▶▶ Medical Tips

The composition of the cervical spine

The cervical vertebrae and the skull constitute the occipital-cervical joint, with physiological lordosis, divided into upper cervical vertebrae (C1, C2) and lower cervical vertebrae (C3-C7)

ACPS development history

In 1964, Bohler reported the first case of anterior cervical application of plate screws to the treatment of lower cervical spine fractures.

In the 70s of the 20th century, Orzco and Tapies applied the AO short-segment H-shaped plate to the anterior cervical fixation.

In 1986, Morsche and other AO scholars first designed the Cervical spine locking plate (CSLP).

Indications (C2-T1)

Trauma, cervical degenerative disease, tumor, deformity, false joint formation, combined anterior and posterior surgery

Skills

Plate-fixed nail assembly: Restrictive system is suitable for strong fixation of trauma and tumor cases.

Plate-adjustable nail assembly: semi-restrictive system, which can place screws at multiple angles according to the intraoperative anatomy, and allows load sharing between the bone graft block and the nail plate structure; suitable for postoperative fixation of cervical degenerative diseases.

Steel plate-mixed assembly

The type of structure can be determined according to the anatomy or indications during the operation.

Increase operational flexibility and better adapt to surgical needs.

Ubicación : No.2, 16#, ChangXing Road, Development District, Zhangjiagang City, Jiangsu Province, China, 215600 Zhangjiagang City,
Persona a contactar : inature Tao, +86 13358048801

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
ACPS Anterior Cervical Plates

Buscar en la categoria : Medicina
Buscar en la categoria :
plates, acps, cervical, anterior
Francia 59590 B2B Servicios
GATE VALVE

Miércoles 14 septiembre 2016

Cantidad : 5000 - Precio : 50,00 €

Gate Valves (F7 Type) DIN Standard F7 Gate valves / (Length acc.to DIN EN 558-1,face to face series 26 ) DIN F7 Gate valve DIN Absperrschieber F7 DIN Válvulas de compuerta F7 DIN F7 šoupátko stavební délka dle DIN EN558-1 serie 26 DIN Standard F7 sluseventil (lengde iht. DIN EN 558-1...)

ETM Armaturen

  • 59590 - Henri Durre
  • 86 577 67953935
Taiwán 24158 Bienes de equipo
CNC Sliding Double-Column EDM Series M1510-2H~M3010-2H

Jueves 06 agosto 2015

Cantidad : 30 sets

The X. Y& Z axes utilize AC servo motors. Multi-cavities machining, ORBIT-CUT machining & Helix machining. A.T.C. (Automatic Tool change) & C-axis machining available. The Circle Angle of Sparking is lower than 0.02mm. The best surface roughness (Ra) is better than 0...

Sane Kuei Machinery Co., Ltd

Taiwán 334 Bienes de equipo
Rotary Round Bottle Labeling Machine LR-435S

Viernes 03 mayo 2024

Precio : depend on situation

Rotary Round Bottle Labeling Machine Model No.: LR-435S Rotary Round Bottle Labeling Machine LR-435S is a labeling machine for round bottle. A durable machine provides high efficiency. FEATURES: - Stepper Motor for fast and accurate labeling performan - Variable labeling / conveyor...

Autopack Co.,Ltd