Informática

ACREL AMC SERIES DATA CENTER MONITOR MODULE

Cantidad : 10000piece   Precio : 5-500USD/piece

Acrel data center monitoring system solution is to improve the power efficiency of the data center and reduce the energy consumption of equipment. First of all, monitor each electrical load, and there are many load loops in the data center. Traditional measuring instruments cannot meet the requirements of cost, volume, installation, construction and other aspects. Therefore, it is necessary to adopt AMC Series Data Center Monitor Module suitable for the centralized monitoring requirements of the data center device.

AMC Series Data Center Monitor Module For Sale

This series of products has a compact design, adapts to the characteristics of many load circuits in data centers, realizes high integration of monitoring circuits, and can accurately monitor each AC or DC load in the data center.

AMC16Z-ZA AC Multi Channel Energy Meter

AMC16Z-FAK48 Multi Channel Din Rail AC Power Meter

AMC16Z-ZD DC Multi Channels Din Rail Power Meter

AMC16Z-FDK24/48 DC Multi Circuits Energy Meter

AMC100-FAK30/48 Multi Channel Din Rail Ac Power Meter

AMC100-ZA AC Multi Channel Energy Meter

AMC Series Data Center Monitor Module Data Sheet

Type Model

Function description

AMC16Z-ZA

Monitor the full power parameters of A+B double-way three-phase AC incomingcircuit,6-way switch state monitoring,2-way alarm output,2-way leakagemonitoring, 1-way temperature and humidity detection,1-way RS485communication, and phase-sequence detection.

AMC16Z-FA

Monitor the full power parameters of 24 branches of A+B double-way ACoutgoing line,1-way RS485 communication and phase adjustment.

AMC16Z-FAK24

Monitor the full power parameters and switch state of 24 branches of A+Bdouble-way AC outgoing line,1-way RS485 communication and phaseadjustment.

AMC16Z-FAK48

Monitor the full power parameters and switch state of 48 branches of A+Bdouble-way AC outgoing line,1-way RS485 communication and phaseadjustment.

AMC16Z-KA

Wet contact,monitoring A+B total 48 branch switch state,1-way RS485communication.

AMC16Z-KD

Dry contact,monitoring A+B total 48 branch switch state,1-way RS485communication.

AMC16Z-AC220V

AC220V extended power supply,and use when the monitoring circuit is beyond 96 branches of A+B

AMC100-ZA

Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications

AMC100-FAK30

Monitor the full power parameters and switch status of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication

AMC100-FAK48

Monitor the full power parameters and switch status of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication

AMC100-FA30

Monitor the full power parameters of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication

AMC100-FA48

Monitor the full power parameters of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication

AMC100-KA30

Wet contact, monitor the switching status of 30 branches A+B, 1 RS485 communication

AMC100-KA48

Wet contact, monitor the switching status of 48 branches A+B, 1 RS485 communication

AMC100-KD30

Dry contact, monitor the switching status of 30 branches A+B, 1 RS485 communication

AMC100-KD48

Dry contact, monitor the switching status of 48 branches A+B, 1 RS485 communication

AMC100-FT30

1 way RS485 communication, 30 way temperature measurement

AMC100-FT48

1 way RS485 communication, 48 way temperature measurement

Why it is important for A Data Center Monitoring System?

With the rapid development of data centers, the energy consumption of data centers has become more and more prominent, and the energy management and power supply and distribution design of data centers have become hot issues.

Acrel AMC series AC precision power distribution monitoring device is a measurement device specially designed for data center server power management. The device is compact in design, and can monitor all electrical parameters, input and output switches, and lightning arrester status of A+B two incoming lines and 96 outgoing lines in real time. The alarm thresholds of all measurement channels can be set independently. The limited event immediately triggers the sound and light alarm of the system, which realizes a high degree of integration of the monitoring loop in the volume of the traditional instrument.

AMC Series Data Center Monitor Module FAQs

What a Data Center Monitor Module do in data center?

Real-time monitoring of all electrical parameters, input and output switches and lightning arrester status of A+B two incoming lines and 96 outgoing lines.

How to choose a right Data Center Monitor Module?

It depends which and how many circutis do you need monitor,ac or dc,input line or output line.

What is data center monitor?

Data center monitoring is mainly for the centralized monitoring of power equipment and environment in the computer room, such as power distribution, UPS, air conditioning, video, flooding, smoke detection, etc. We are mainly for the monitoring of power distribution systems.

If you want to know more kinds of electrical monitoring device, please visit our website.

Ubicación : No.5 Dongmeng Road, Nanzha Street, Jiangyin City, Jiangsu Province, China., 214405 Jiangyin,
Persona a contactar : Tim MA, 86 510 86179966

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
ACREL AMC SERIES DATA CENTER MONITOR MODULE

Buscar en la categoria : Informática
Buscar en la categoria :
series, monitor, acrel, module, center, data
Anuncio GOLD
Francia 01220 B2B Servicios
UBIDOCA : BackOffice des voyageurs expatriés          VOTRE COURRIER

Martes 04 junio 2013

VOTRE COURRIER POSTAL SUR INTERNET (BACKOFFICE) www.ubidoca.com Vous voyagez très souvent ? Vous travaillez beaucoup à l'étranger ? Vous avez plusieurs domiciles ? Nous fournissons la solution la plus efficace pour gérer vos affaires et votre courrier postal à distance sur Internet. Nos services - Mise de votre courrier postal sur Internet dès réception par notre équipe. - Vous pouvez le consulter 24h/24, o...

UBIDOCA SARL

  • courrier
  • 01220 - Divonne les Bains
  • 04 50 20 49 70
  • 06 18 63 06 53
Hong Kong 532500 Bienes de equipo
Weighing Scales for body fat and water

Miércoles 04 junio 2014

.Capacity: 3kg-150kg(3301b) .Graduation: 0.1kg/0.21b .High precision strain gauge technology .With tempered safety glass platform ·Button function .Low battery and over load indication .10 measured value memories for 10 users .Measure body fat%/water% by BMI principle .‘'Body fat...

Jerray Electric Appliance Co.,Limited

  • 532500 - Kinglong square
  • +85 2 23 69 69 00
Suiza 3600 Audio / video
Elektro Scooter Mini Bike 120W

Martes 06 enero 2015

Artikelmerkmale: - Fabrikneu und feine Verarbeitung - Laufruhig und umweltfreundlich - Höhenverstellbare Lenksäule und rutschsicherer Griff - Geeignet für Kinder ab 8 Jahren, max. Tragkraft 90kg - 12km/Std. Höchstgeschwindigkeit - Mit 2* 12V 4.5Ah Akku - Langlebige PU Räder, Φ 150mm...

365buy

  • 3600 - Thun
  • 07 62 07 63 81