AD3000-TPA Infant Resuscitator
Cantidad : 5000 Precio : 15-2200USD
With safe, precise and controllable PIP (Peak Inspiratory Pressure) and PEEP (Positive End Expiratory Pressure), Pigeon Medical Infant Resuscitators are easy to operate and can provide temporaty breathing support. It is crucial for NICU units, Nurseries, Delivery and Transport System.
Working Principle of Infant Resuscitator AD3000-TPA
Neonatal resuscitation also known as newborn cpap neonatal resuscitation is an emergency procedure focused on supporting the approximately 10% of newborn children who do not readily begin breathing, putting them at risk of irreversible organ injury and death. Through positive airway pressure, and in severe cases chest compressions, medical personnel can often stimulate neonates to begin breathing on their own, with attendant normalization of heart rate. CPAP infant resusciatator can deliver a more controlled and consistent peak inspiratory pressure (PIP) and positive end-expiratory pressure (PEEP), which helps to protect the newborn's lungs.
Features of Infant Resuscitator AD3000-TPA
Consistent Care
The easy-to-use T-Piece circuit reduce variations in care, ensuring each breath is delivered in a similar manner.
Do More With Less
Powered by 5L/min, NeoPIP requires less gas flow to operate, for less gas consumed and improved transport range.
Durable & Dependable
Each NeoPIP unit is built to last; a solid case and metal fittings resist damage leading to long service life.
Specification of Infant Resuscitator AD3000-TPA
Model |
AD3000-TPA |
Pressure gauge |
-2-10kPa(-20-100cmH2O) |
PIP |
@5 LPM,2-27 cmH2O |
@8 LPM,4-36 cmH2O |
|
@10 LPM,6-42 cmH2O |
|
@15 LPM,12-57 cmH2O |
|
CPCP/PEEP |
@5 LPM,0.3-6 cmH2O |
@8 LPM,0.8-14 cmH2O |
|
@10 LPM,1-17 cmH2O |
|
@15 LPM,2.5-23 cmH2O |
|
Noise |
≤50dB(A) |
Gas source |
0.3MPa-0.4MPa |
Recommended patient weightUp to 10KG |
|
Practical Application of Infant Resuscitator AD3000-TPA
Failure to breathe,including antepartum mechanism, recent intrapartum asphyxia, central nervous system depression, maternal drug abuse etc.
Failure to expand the lungs, including airway obstruction, respiratory distress syndrome, malformations involving the respiratory tract.
Persona a contactar : Zhou Alex , +18 8 98 65 17 88
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de AD3000-TPA Infant Resuscitator Buscar en la categoria : Medicina Buscar en la categoria : ad3000, infant, resuscitator |
Jueves 21 noviembre 2024
- High Speed Front and Back Labeling Machine - Model No.: LD-450S High Speed Front and Back Labeling Machine LD-450S is ideal for simultaneously applying Front and Back pressure sensitive labels to a container. It suits for Round Oval, Square, Rectangular or Irregular products labeling...
Autopack Co.,Ltd
- autopacker
- 33454 - Taoyuan City
- +88 6 33 68 98 06
Jueves 14 noviembre 2024
Dual Piston Volumatical Filling Machine FP425. available for working independently on each system. Cylinder Volume can be customized based on customer's requirement. FEATURES: - Filling volume can be customized based on customer's requirement - Each piston system can be set independently...
Autopack Co.,Ltd
- autopacker
- 33454 - Taoyuan City
- +88 6 33 68 98 06
Miércoles 14 septiembre 2016
Cantidad : 5000 - Precio : 100,00 €
Bellows Seal Stop Valves (Angle Type) DIN Angle Type Bellows Sealed Stop Valve DIN Bellows Seal Globe Valve DIN Faltenbalgventil Eckform DIN Válvulas de fuelle(Paso angular.) DIN ventil uzavírací s vlnovcem rohový DIN Standard seteventil med belg (Vinkel modell) DIN Standardında...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935