B2B Servicios

Aspira Catheter Instructions

Cantidad : 5   Precio : 45-1300 USD

Aspira Catheter Instructions

What Is An Aspiration Catheter?

The Cylone™ Aspiration Catheter is intended for use in the removal/aspiration of emboli and thrombi from selected blood vessels in the arterial system including the peripheral and neurovasculatures. Moreover, the Cylone™ Aspiration Catheter can be used to facilitate the introduction of diagnostic or therapeutic agents.

Aspiration Catheter Use

Aspiration catheters are medical devices used in various medical procedures to remove thrombus, which is a blood clot that may obstruct blood vessels. These catheters are designed with a unique tip that creates a negative pressure when connected to an aspiration pump. The negative pressure enables the catheter to aspirate or withdraw the thrombus, restoring blood flow and preventing potential complications.

Aspiration catheters are commonly used in interventional cardiology and neurology procedures. In cardiology, they are employed during percutaneous coronary interventions (PCI) to remove thrombus or debris from narrowed coronary arteries, improving blood flow and restoring heart function. In neurology, aspiration catheters are utilized in the management of stroke patients, where they help retrieve thrombi obstructing blood flow in cerebral arteries, reducing the risk of ischemic stroke.

Aspiration Catheter Procedure

a. Preoperative Preparation: Before placing the aspiration catheter, the doctor assesses the patient's condition, using imaging techniques such as X-rays, CT scans, or angiography to determine the location and size of the thrombus. Additionally, the doctor collects the patient's medical history and allergy information to ensure a safe and accurate procedure.

b. Local Anesthesia: During the surgery, the doctor administers local anesthesia to the placement site to minimize patient discomfort.

c. Guidewire Placement: The doctor inserts a guidewire into the blood vessel and navigates it through the vascular system to the location of the thrombus. This helps in precise positioning and guiding the aspiration catheter.

d. Placing the Aspiration Catheter: Once the guidewire is in the desired location, the doctor gently advances the aspiration catheter along the guidewire. This process is usually performed under real-time imaging guidance to ensure accurate placement.

Usage Procedure:

a. Connecting the Aspiration Pump: After the aspiration catheter is properly positioned, the doctor connects it to the aspiration pump. This generates negative pressure, allowing the aspiration catheter to suction the thrombus and other unwanted materials.

b. Thrombus Aspiration: Through the negative pressure generated by the aspiration pump, the aspiration catheter suctions and removes the thrombus from the blood vessel. This process is typically performed progressively until the thrombus is entirely removed.

c. Monitoring and Adjusting: Throughout the aspiration process, the doctor closely monitors blood flow and the position of the aspiration catheter. If necessary, the doctor may make slight adjustments to ensure thorough removal of the thrombus.

d. Completing the Procedure: Once the thrombus is completely cleared, the doctor removes both the aspiration catheter and guidewire from the patient's blood vessel. Mild pressure may be applied to prevent bleeding, and the wound is then covered for further treatment.

As one of the professional neurovascular medical device companies in China, Zylox-Tonbridge provides quality aspiration catheter solutions for patients worldwide. Feel free to contact us at any time.

Zylox medical is a leading player in the peripheral and neurovascular interventional medical device market in China. As a fully integrated medical device company, we have strong R&D and manufacturing capabilities, multiple specialized technology platforms, and proven commercialization capabilities.

Ubicación : No. 270, Shuyun Road, Cangqian Street, Hangzhou, Zhejiang Province, P.R.China, 311121 Zyloxtb,
Persona a contactar : .com Zyloxtb, 0571 88610082

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
Aspira Catheter Instructions

Buscar en la categoria : B2B Servicios
Buscar en la categoria :
aspira, catheter, instructions
Detector de humo EI ELECTRONICS EI650 autónoma de 10 años

Viernes 09 septiembre 2016

Cantidad : 400 - Precio : 8,00 €

Déstokage 400 detectores de humo EI ELECTRONICS EI650 fabricado en Europa con una batería de litio hasta autónoma en 2026 (20 estuches de 20 detectores con tornillos de montaje de pared y manual de instrucciones en francés). CARACTERÍSTICAS TÉCNICAS - Botón de prueba y descanso...

DOMERCA

  • 69100 - VILLEURBANNE
  • 06 25 41 37 41
Man-Roland R 504 HOB - Año 2007

Sábado 15 noviembre 2014

Vendo Man-Roland R 504 HOB , Año 2007 53x74 - 4 colores - Consola RCI 2 - Techkon ExPresso Densitometer - PPL (Semi-Automatic sistema de ajuste) - Lavado Automatico : cilindros mantillas, Imp. & los rodillos entintadores - Ajuste de Formato y Grosor del papel Automático - Cocking...

ACS DIFFUSION s.a.s.

  • acsdiffusionsa
  • 42952 - Saint-Etienne
  • 0033 (0)4 77 92 77 88
  • 06 10 63 37 83
Luxemburgo L-1274 Alimentación
WSC SARL : Lot de Barrières autoalimentées    WSC SARL Contact

Jueves 15 noviembre 2007

WSC SARL Contact : Velizar Todorov (Mr) Tel : 00352 22 9999 5523 Mobile : 00352 661 655565 Fax : 00352 22 9999 5499 Luxembourg Lot de Barrières autoalimentées, télécommandées, pour protéger un parking privé ou empêcher le passage vers une voie d'accès privée. Prévue pour les emplacements...

WSC Sarl

  • wsclux
  • L-1274 - Howald
  • 00352 22 9999 5523