AT230 Thermal Cycling Tester
AT230 THERMAL CYCLING TESTER


Application:
AT230 Thermal Cycling Tester is designed according ISO and ASTM standard requirement; it's mainly used to check the leakage status of composite pipe & fittings when subjected to specify cycling times under specified internal pressure load. It's widely used in plastic pipe manufacture factory and some Labs.
Standards: ASTM F 1335-98; ISO 10508, 12293; GB/T 18742, 18992, 18993, 18998, 19472; CJ/T 138, 175
Note: For more standards, please contact us
Features:
1. Temperature control system
1) This control system equips separate temperature detector for cold water tank, hot water tank, header pipe input nozzle, header pipe output nozzle. Take 6 working as sample, there should be 16 pcs detectors
2) Main machine temperature control range: 10℃~98℃
3) Independent temperature detector to monitor sample room temperature
2. Pressure control system
1) Equipped with 16-byte A/D transverter to collect pressure
2) The pressure sensor range is 0 ~ 1.6MPa, display resolution reach to 0.001MPa

3. Water flow control system
1) Each work station equipped with a flow meter
2) The resolution of flow meter reach to 0.01m/s and 16 byte A/D transverter for water sampling

4. Communicate system
1) 16 pcs electromagnetic valve controller to control water input and output
2) 4 pcs electric parts to control the circulating pump
3) 4 pcs electric part to control heating and cooling system
4) One electric part to control water supply

5. General features
1) High temperature and high pressure only exist in the sample and short piping, that all the electric parts in circulation line work at normal pressure to attain a long service life.
2) Lockable transparent folding doors make samples installation more easily and allow easy access to all samples from three sides.


3) Testing control and monitoring of individually station takes over PLC and touch screen terminal.
4) Individual circulation time, flow rate and pressure can be selected.
5) It provides test constancy as regards to temperature, pressure and flow rate as well as lowering the energy consumption.
6) Several reliable safeguard, liquid level measuring devices, emergency stop switch and cord switch ensure the tester to be out of action in time if the test fails or piping system bursts. Doors shall be locked during testing period.
7) Pre-stress system was introduced to apply the initial tensile stress. This system is optional.
8) System enables pressure calibration and temperature calibration during testing, it means that system may continue running during calibration.
9) High quality grundfoss pumps are used to provide press in sample strings. Automatic water filling design ensures full tank capacity during the whole time.

Circuit diagram


Technical Specification:
|
Model |
AT230 |
|
Max. pressure |
1.6MPa |
|
Pressure control accuracy |
±0.05Mpa |
|
Pressure display resolution |
0.001Mpa |
|
Number of test stations |
6 (can customize) |
|
Alternation time between hot water and cold water |
≤1 min |
|
Cycle period |
300 ~ 1200s |
|
Number of cycles |
1 ~ 10,0000 adjustable |
|
Cold water temperature range |
15℃ ~ R.T adjustable |
|
Cold water temperature accuracy |
±2℃ |
|
Hot water temperature range |
R.T ~ 98℃ |
|
Hot water temperature accuracy |
±1℃ |
|
Temperature display resolution |
1℃ |
|
Temperature uniformity |
≤±1℃ |
|
Water flow accuracy |
0.01m/s |
|
Water flow display resolution |
0.001m/s |
|
Ambient temperature |
23℃±2℃ |
|
Max. total cross-section diameter of all connect test samples |
6200mm2 (2*Φ63) |
|
Power supply |
3phase, AC380V, 50Hz, 25KW |
|
Dimensions |
4600×2900×2000mm |
Standard Configuration:
|
No. |
Item |
Quantity |
|
1 |
Main machine |
1 set |
|
2 |
Sample chamber |
1 set |
|
3 |
Cold water tank |
1 set |
|
4 |
Chiller |
1 pcs |
|
5 |
Heat exchanger |
1 pcs |
|
6 |
Hot water tank |
1 set |
|
7 |
Heater for hot water tank |
1 pcs |
|
8 |
Control system |
1 pcs |
|
9 |
Pipe fixed system |
1 set |
|
10 |
Packing list |
1pc |
|
11 |
Quality certificate |
1pc |
|
12 |
User manual |
1pc |
Optional Configuration:
|
No. |
Item |
|
1 |
Flow measurement system |
|
2 |
Pre-stress system |
Persona a contactar : Eric Qin, +86 186 18655041869
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
|
Esta página es acerca de los importadores y exportadores de AT230 Thermal Cycling Tester Buscar en la categoria : Bienes de equipo Buscar en la categoria : at230, thermal, cycling, tester |
Tuesday 14 February 2023
Bulb light applied with patented LED technology. It can sterlize the air and surface around while offer general ligting. Specification of Bulb Light UVWL12BLXX93 Model Input Voltage Power Efficacy CCT CRI Size Package Bulb Light UVWL12BLXX93 AC100-265V AC175-265V 12W ...
Foshan Feiliu Enterprise Management co.LTD
- 528300 - Foshan
- 86 757 29311003
Thursday 30 June 2022
Cantidad : 100
La gamme S3300 rassemble une nouvelle génération de smart switches Web manageables stackables Gigabit dotés de 4 ports 10 Gigabit, pouvant être utilisés pour des liaisons montantes et/ou dans un stack avec d'autres switches S3300. Le stack mixte avec une sélection de switches 10 Gigabit...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14
Saturday 09 July 2022
Cantidad : 100
Cette radio Philips fonctionne sur piles ou sur secteur pour plus de confort et de flexibilité. Lorsque vous n'avez pas accès à une prise électrique ou lorsque vous êtes gêné par la vue de câbles disgracieux, optez pour un fonctionnement sur piles. Lorsque vous devez pouvoir compter...
MaKant Europe GmbH & Co. KG
- 60386 - Frankfurt am Main
- +49 (69) 9 150 750 14