Dynamic Image Analysis Particle Size for Dry Measurement

The BeVision D2 provides an efficient solution to the size and shape analysis of dry, high-flowability powders or granules. Tens of thousands of particles can be measured by a BeVision D2 within three minutes. Combining a high-speed camera with a precise telecentric lens, the BeVision D2 is able to efficiently analyze the size and shape of particles in the range of 30 - 10,000 µm. The BeVision software helps you evaluate particle size and shape from 24 different aspects and further organizes the data into an all-around validation of particles.

Measurement range: 30 – 10,000 µm

24 different particle size and shape parameters

Reduction of workload and time

Outstanding reproducibility

Results in compliance with ISO 9276-6

Fully automated operation

Powerful software provides a comprehensive evaluation

Comparable with sieving results

•Why Image Analysis Method?

Easy

Capture an image of particles, identify particles, then measure their size and shape. Every step of image analysis is easy and clear.

Shape analysis

Based on a direct view of particles, it is possible to analyze not only the size of particles, but also their shape.

Seeing is believing

The image analysis method determines the size and shape of every individual particle and then sums it up to form a statistic. Details of particle size or shape distribution can be accurately provided.

•Why Dynamic Image Analysis Method?

Efficiency

A continuous particle flow passing through the measurement zone helps achieve a higher efficiency of the measurement.

Oversized particle sensitivity

The dynamic image analysis method is sensitive to oversized particles; it is even possible to estimate the size of oversized particles.

Reliable results

The maximized number of measured particles ensures the statistical significance of measurement results.

•BeVision D2 Hardware: Guaranteed Accuracy and Efficiency for You

To measure the size and shape of particles over a great variety of applications, the BeVision D2 has equipped with a comprehensive range of hardware. Corresponding to the sample material properties, selecting the best hardware can help measure the size and shape of particles with optimum accuracy and efficiency.

•Particle Size and Shape Parameters

Size parameters

Equivalent diameters: area-equivalent diameterperimeter-equivalent diameter; Feret diameters: maximum and minimum Feret diameters, XLF ("length")

Martin diameters: maximum and minimum Martin diameters; Legendre ellipse: major and minor axes

Shape parameters

Size difference in 2 directions: aspect ratioL/W ratioellipse ratio; Round-likeness and rectangle-likeness: Circularityirregularitycompactnessextentbox ratio

Contour concavity: Concavityconvexitysolidity; For elongated particles: Elongationstraightness

Performance

Dry dispersion provided by BeVision D2 particle size analyser makes it suitable for a diverse range of applications.

1. Accuracy Calibration

Use the scale to verify accuracy and convert the pixel to actual size during the test and analysis. Ensure the results are accurate and reliable.

2. Recognize Connected Paticles

The main purpose of the function is to filter agglomerate or adhesive particles, in order to avoid that test result is affected. Connected particles refer to agglomerate particles forming by two or more than two adhesive particles. The feature of connected particles is that there is sunken area in particle image. Through judging the size, depth and angle of the sunken area, connected particles can be recognized.

3. Automatic Circulation and Dispersion System

The dry system adopts electromagnetic vibration feeding, gravity-driven dispersion, which ensures sampling is uniform and continuous.

4. Application of BeVision D2 particle image analyzer
Dry method: Applies to analyze granular samples between 30 um to 10 mm, such as salt, sugar, plastic products, catalyst, abrasive, carbon products, sand, coal, coffee, refractory, food, polystyrene, glass, ceramics, fertilizer, medicine, ore, etc.

5. Imaging Theory of Free Falling Particles

Adopts high-speed CCD camera-120 images per second, microsecond exposure time, avoid trailing phenomenon in moving particle. More than 10 thousand particles could be analyzed per minute by the special image processing software of these dynamic image particle measuring services. During the process of free falling of particles, shoot particle images which pass the lens randomly. Meanwhile, software quickly recognizes and processes particles, and screen displays images, particle size and particle shape data for each particle in real time. As it adopts high-speed CCD that can reach 100frame/min, thousands of particles can be shot and processed per minute, and image process software can recognize and extract adhesive particles automatically. These technologies improve analysis speed, precision and accuracy of particle image greatly. As one of the professional laser particle sizing instrument suppliers in China, Bettersize has been striving to provide our customers with high quality particle size analyzer.

If you want to know more details of image analyzer grain size, please visit our website.

Ubicación : No.9, Ganquan Road, Jinquan Industrial Park, Dandong, Liaoning, China., 118009 Dandong,
Persona a contactar : Xu Spring , +15 1 41 55 76 96

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
BeVision D2

Buscar en la categoria : Batería de cocina
Buscar en la categoria :
bevision
Thailandia 10110 Materias primeras
HDPE / LDPE / LLDPE gránulos vírgenes

Jueves 08 octubre 2015

Precio : 900euros

H.S. Code Promo: 39041090 Pureté: 99% Apparence: Poudre blanche ou grains 1. granulés de hdpe vierges Caractéristique Ce granulé de HDPE est l'extrusion, qualité de tube avec une bonne résistance aux intempéries, une bonne dispersion de noir de carbone également une excellente...

SA BANGKOK IMPORT AND EXPORT LTD

  • 10110 - Bangkok
  • +66 9 40 61 68 72
Thailandia 15140 Alimentación
Refinado Azúcar granulado ( ICUMSA 45 )

Jueves 16 julio 2015

BLANCO REFINADO DE CAÑA DE AZÚCAR ICUMSA 45 ESPECIFICACIONES : APTOS PARA EL CONSUMO HUMANO POLARIZACIÓN : 99,80 % MÍNIMO HUMEDAD : 00,04 % MÁXIMO SULPHATEASH CONTENIDO: 00,04 % MÁXIMO GRANULACIÓN : medio a fino SOLUBILIDAD : 100 % DRY y de flujo libre RADIACIÓN : NORMAL W / O PRESENCIA...

TRADEX GROUP CO LTD

  • 15140 - opburi
  • +6661409539
Thailandia 5000 Alimentación
Las semillas de cáñamo sin cáscara

Sábado 20 febrero 2016

Cantidad : 100 MT PER - Precio : 2000 usd per mt CIF

Hemp seeds Product Name: Hemp seed extract Latin Name: Cannabis sativa L Appearance: Brown yellow powder Part used: Seed Application: Health-care products Shelf Life: 24(month) Name Hemp Seed Botanical source Cannabis sativa L. Specification 3.5mm belwo,3.5-5.0mm...

Khun Jack Partnership Ltd

  • 5000 - Chaing Mai
  • +66 9 68 75 20 43