B2B Servicios

Chromatography System

Hanbon advanced chromatography systems has reliable performance and flexible configuration, and can provide Bio-Lab® laboratory chromatography system, Bio-Pro® pilot&process chromatography system, etc.

ommon Principles Of Process Scale-Up: Linear Scale-Up

Linear scale-up is the most common principle used in process scale-up. By linear scale-up, we mean that we can obtain almost uniform bioprocess chromatography results from laboratory scale to pilot results or industrial production level. The core idea is to keep the column height and linear flow rate constant and only scale up the column diameter and volume flow rate. A fixed column height and linear flow rate theoretically ensures the same retention time, the number of CVs used in chromatography and the number of CVs of the eluted sample, maximizing the same purification results. Theoretically, this linear scale-up of the purification separation behavior should be very similar, thus ensuring a successful scale-up of the ion chromatography process. However, some additional factors need to be considered, including a decrease in column tube support (increased pressure drop), column efficiency/column bed instability, sample diffusion (peak spreading), and dead volume of the system and tubing.

Conversion Of Linear Flow Rates (Cm/H) To Volumetric (Ml/Min) Flow Rates

When comparing results from columns of different sizes, it is convenient to express the flow rate as a linear flow rate (cm/h). However, flow rates are often measured as volumetric flow rates (ml/min). In order to convert between linear and volumetric flow rates, one of the following equations can be used .

Linear flow rate (cm/h) to volumetric (ml/min) flow rate

Volumetric flow rate (ml/min) = linear flow rate (cm/h) / 60 x column cross-sectional area (cm2)

=Y/60×π×d2/4

Y = linear flow rate (cm/h)

d = internal diameter of the column (cm)

e.g.:

There is a glass column (inner diameter 1.6 cm), when the linear flow rate is 150 cm/h, what is the volumetric flow rate?

Y=Linear flow rate = 150cm/h

d = inner diameter of the column = 1.6 cm

Volumetric flow rate = 150 x π x 1.6 x 1.6/(60 x 4)

From volumetric flow rate (ml/min) to linear flow rate (cm/h)

Linear flow rate (cm/h) = volumetric flow rate (ml/min) x 60/column cross-sectional area (cm2)

=Z×60×4/π×d2

Z = volumetric flow rate of the column (ml/min)

d = inner diameter of the column (cm)

e.g.:

There is a glass column (inner diameter 0.5 cm), when the volumetric flow rate is 1 ml/min, what is the linear flow rate?

Z = volumetric flow rate of the column = 1 ml/min

d = inner diameter of the column = 0.5 cm

Linear flow rate = 1 x 60 x 4/(π x 0.5 x 0.5) cm/h = 305.6 cm/h

We provide chromatography step by step method, chromatography purification method, chromatography process example, anion exchange chromatography elution, equipment used for chromatography, etc. For more information, please feel free to contact us!

Ubicación : No.1-9 jixian road, economic development zone, 223005 Jiangsu,
Persona a contactar : com hanbon, 86 0517 83706900

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
Chromatography System

Buscar en la categoria : B2B Servicios
Buscar en la categoria :
system, chromatography
Francia 13008 Telefonía
IPHONE 3G 3GS GARDE B/C 35E HT

Monday 27 April 2015

Cantidad : 230 - Precio : 35HT

IPHONE 3G 3GS GRADO B / C 35E HT IPHONE 3G 3GS GRADO B / C 35E HT Cantidad : 225 Precio: 35HT HOLA VENTA DE LOTE 225 IPHONE 3G 3GS 8GIGA 16GIGA 32GIGA GRADO B / C FUNCIONAL TASA O MARSEILLE 35 euros HT.LIVRAISON PARIS HECHO . TENEMOS OTRO JUEGO DE NOKIA ASHA A25 EURO HT . 25pieces...

WLF

  • 13008 - marseille
  • +33 6 98 19 24 26
India 91706 Búsqueda/compra
Cheap Okidata toner cartridges for all the printer models

Thursday 28 May 2015

Have you got frustrated by spending much money in your printers or ink cartridges? Get away from all as we are here to fulfill all your printing needs. We, at angryinks, offer a best and cost effective range of Okidata toner cartridges for all the Okidata printer models. From our...

Angry Inks

  • 91706 - baldwin park
  • 8883232727
Hong Kong 999077 Bienes de equipo
Unitronics Vision 570 Color OPLC

Thursday 15 January 2026

Unitronics Vision 570 Color OPLC – Automate Control Engineering Ltd. (winston@automate-ace.com) The new Vision570 offers a quality color touchscreen HMI, integrated into the newest member of the Vision series PLCs. Marvelously designed and richly featured, the Vision570 can upgrade any machine...

Automate Control Engineering Ltd.