Bienes de equipo

Cone Calorimeter

A cone calorimeter is a fire test tool that is based on the amount of heat released during the combustion process directly related to the oxygen consumption in the combustion process. The amount of heat generated is directly proportional to the severity of the fire, such as the rate of fire growth. In order to obtain the flammability of the material, this is exposed to an external radiation heat source. Therefore, since this is a forced combustion test, the cone value is generally considered to reflect the second ignitability of the ignition.

  Standard:

  ISO5660,ASTM E 1354, ASTM E 1474, ASTM E 1740, ASTM F 1550, ASTM D 6113, NFPA 264, CAN ULC 135, BS 476

  Scope of application:

  The Cone Calorimeter is the most significant bench scale instrument in the field of fire testing.

  Principle:

  A sample is placed in a "cone" shaped radiant heater. Normally, the sample is exposed to 35 kW / m2 of external flux-forming heaters. However, for more refractories the heater is often increased to 50 kW / m2. Once sufficient pyrolysis products are produced, ignition occurs. Combustion products pass through a conical heater and through an instrument discharge tube. The measured / calculated values are usually important including, but not limited to, the maximum ignition time, the mass loss rate during combustion, the maximum amount of time and heat released during combustion, the total amount released during the test
Heat complete system includes:

  1. Conical heater - in a truncated cone, 230V, 5000W, with a heat output of 100 kW / m2

  2. Test the sample device in horizontal or vertical.

  3. 3 K-type thermocouple and 3 PID temperature controllers for temperature regulation

  4. Opening and closing mechanism - to protect the sample area before testing to ensure that the initial quality measurement is stable, the operator can have additional time to test the system before testing. For flammable samples, if there is no opening and closing mechanism, it is easy to burn prematurely. This extra time is very important to the operator

  5. Sample holder - sample size 100mm x 100mm, thickness of not more than 50mm, placed horizontally or vertically

  6. Load cell - quality measurement by strain gage component test, the accuracy of up to 0.01g. Equipped with quick electronic weighing components, mechanical stop device can avoid damage caused by movement, given the stable results, to ensure that equipment longevity

  7. Spark ignition - 10kV spark igniter, equipped with a safety cease-fire device. The igniter is automatically positioned by means of a lever connected to the closing mechanism

  8. Exhaust system - made of stainless steel to extend life. (Flow rate adjustable from 0 g / s to 50 g / s with an accuracy of at least 0.1 g / s), and orifice flow testers (thermocouples and differential pressure transducers), including hoods, gas sample sockets and exhaust fans. Common tests are typically 24 l / s

  9. Gas sampling - including particulate filter, freezing cold trap, pump, drying cylinder, flow controller

  10. Oxygen analysis - paramagnetic oxygen analyzer, 0-25%, standard performance

  11. Smoke fog - measured with a laser system using a photodiode, 0.5 mW helium-neon laser, primary and standby photodetectors. With positioning bracket and 0.3,0.8 neutral density filter for calibration

  12. Heat flow meter - used to set the level of radiation on the sample surface

  13. The burner calibration-calibration apparatus tested the heat release rate by using 99.5% pure methane

  14. DATA ACQUISITION - An Agilent wheel data collector / converter with 3-hole card slot, 6 1/2 digit (22 bit) internal DMM for 120 single-ended measurements or 48 double-ended measurements. Scan rate up to 250 channels / s with 115k baud RS232 and PCI GPIB interface. All readings are recorded automatically, with a stable reading of 50000 in the memory

  15. Cone Calorimeter Software - Operating languages include English, French, German, Spanish and Japanese. The user interface is a Windows operating system with easy-to-use button operations, standard Windows data entry, drop-down options, click-to-select, and switch

  Feature:

  1). Displays the instrument status.

  2). Calibrate the instrument and store the calibration results.

  3). Collect the test data.

  4). Calculate the required parameters.

  5) Display the results by the standard way.

  6). Multiple tests are averaged.

  7). Data entry to FDMS (Fire Data Management System) - Most European and US laboratories apply the system format, sharing data between different laboratory calorimeters.

  8). the file output is in CSV (Comma Separated File) format, which can be quickly converted to a spreadsheet

    Optional Configuration:

  1, Carbon dioxide and carbon monoxide - available NDIR gas analyzer.

  2, Hydrogen chloride - heating supply lines and gas analyzers.

  3, Controlled gas accessories - for low-oxygen sample analysis.

  4, the quality of the loss of calorimeter.

  5, FTIR toxicity tester.

   Optional Configuration:

  1, Carbon dioxide and carbon monoxide - available NDIR gas analyzer.

  2, Hydrogen chloride - heating supply lines and gas analyzers.

  3, Controlled gas accessories - for low-oxygen sample analysis.

  4, the quality of the loss of calorimeter.

  5, FTIR toxicity tester.

  6, the protection of door-to protect the operator does not inhale poisonous samples generated by the flue gas. The steel plate blocks the rear, the exhaust hood blocks the top, and the test door blocks the bottom, protecting the door against the last side.

Ubicación : No. 2578 Minhang District Gu Dai Road, Shanghai, 201199 Shanghai,
Persona a contactar : Sun Qin, +86 21 6780 0179

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
Cone Calorimeter

Buscar en la categoria : Bienes de equipo
Buscar en la categoria :
cone, calorimeter
Thailandia 50000 Alimentación
ICUMSA 45 White Refined Cane and Beet Sugar 2016 Crop

Tuesday 16 February 2016

Cantidad : 10,000MT - Precio : 210 USD/MT CIF

Refined Sugar Icumsa 45 RBU, Icumsa 150, Icumsa 600-1200 Competitive prices & Current cropping Quality guarantee ICUMSA 45 is a highly refined sugar, and it is easily recognizable by its distinctive sparkling white color and pure Sucrose taste. It is suitable for human consumption...

KHUN JACK PARTNERSHIP LIMITED

  • 50000 - CHIANG MAI
  • +66 9 56 19 49 81
Thailandia 5000 Alimentación
Las semillas de cáñamo sin cáscara

Saturday 20 February 2016

Cantidad : 100 MT PER - Precio : 2000 usd per mt CIF

Hemp seeds Product Name: Hemp seed extract Latin Name: Cannabis sativa L Appearance: Brown yellow powder Part used: Seed Application: Health-care products Shelf Life: 24(month) Name Hemp Seed Botanical source Cannabis sativa L. Specification 3.5mm belwo,3.5-5.0mm...

Khun Jack Partnership Ltd

  • 5000 - Chaing Mai
  • +66 9 68 75 20 43
Irán 19339 Construcción
PORTLAND Cement / Clinker

Tuesday 23 December 2025

- PORTLAND Cement / Clinker - Quantity : Min. 12.500 MT Price : 42 USD - 48 USD Manufacturer Agent for PORTLAND Cement Type : II , IV , 1-32.5 , 1-42.5 Price FOB Dubai from 46USD/MT - 44 USD/MT * + Clinker Type II , IV , 32.5 , 42.5 Price FOB Dubai from 46 USD/MT - 44 USD/MT *...

AHTM&CO.

  • nourayin
  • 19339 - Teheran
  • +9821 88786321
  • +98912 3805131