CSCW-N180 Stick Curtain Wall
Stick built curtain wall CSCW-N180 is an efficient and reliable curtain wall system with 80mm width profile sightline. Compare to unitized curtain wall, it is flexible for different construction condition and structures, and offer a competitive product cost.
Overview of CSCW-N180 Stick Built Glass Curtain Wall
System |
Stick Curtain Wall (Non-Thermal Break) |
Model No. |
CSCW-N180 |
Material |
Aluminum Alloy/Glass/Aluminum Sheet/Aluminum Composite Panel/Galvanized Sheet |
Glass Type |
Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak |
Cooperated Glass Brand |
Vitro (Formerly PPG) /Pilkington/Xinyi(SYG)/Yaopi (SYP) /Fuyao/Southglass (SG) /Kibing/CNG/TaiwanGlass |
Surface Treatment |
Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain |
Profile Brand |
6063-T5/6063-T6/6061-T6 (Brackets) |
Thermal Profile |
Non-Thermal Break |
Standards |
In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO |
Application |
Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization |
System Customization |
Available |
Data of of CSCW-N180 Stick Built Curtain Wall System
Testing Data of CSCW-N180 Stick Curtain Wall
Design Wind Pressure |
Wsls=+1.61KPA/-2.09KAP, Wuls=+2.49KPA/-3.23KPA |
|
Test |
Pressure |
Results |
Preloading(Clause 8.2.2 of AS/NZS4284: 2008) |
+1.61kpa |
No separation, plastic deformations or deleterious was observed. |
-2.09kpa |
||
Preliminary Water Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284: 2008) |
+482kPa |
There were no leaks. |
Preliminary Water Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284: 2008) |
241-482-241 (Pa) |
There were no leaks. |
321-642-321 (Pa) |
||
482-964-482 (Pa) |
||
Structural Test at Serviceability Limit State Wind Pressure (Wsls)(Clause 8.3 of AS/NZS 4284: 2008) |
+1.61kpa |
During the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits. |
-2.09kpa |
||
Air Infiltration Test (Clause 8.4 of AS/NZS 4284: 2008) |
+/-165Pa |
The rate of air leakage of the specimen was within the allowable values. |
Water Test under Static Water Test under Static 4284: 2008) |
+482Pa |
There were no leaks. |
Water Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284: 2008) |
241-482-241 (Pa) |
There were no leaks. |
321-642-321 (Pa) |
||
482-964-482 (Pa) |
||
Structural ProofTest at Ultimate Limit State Wind Pressure (Wuls) (Clause 8.8 of AS/NZS 4284: 2008) |
+2.49kpa |
No collapse of the test specimen was observed under the specified pressure. |
-3.23kpa |
||
Seal Degradation Test(Clause 8.10 of AS/NZS 4284: 2008) |
241-482-241 (Pa) |
No water leakage was observed. |
321-642-321 (Pa) |
||
482-964-482 (Pa) |
Thermal Data of CSCW-N180 Stick Curtain Wall
NFRC Procedures |
NFRC100SB, NFRC200-2010, and NFRC500-2010 |
Software Tools |
THERM 7.4.3.0 and WINDOW 7.4.6.0 |
Configuration |
6 CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU |
Panel Dimension |
1705mm Wide 3245mm High |
Frame |
Painted Aluminum |
Panel U-value |
3.041W/m2k |
Visible Light Transmission |
0.271 |
SHGC |
0.197 |
Frame Data of CSCW-N180 Stick Curtain Wall
Parts Location |
Frame Area/m2 |
Edge Area/m2 |
U-Value(Frame) |
U-Value(Edge) |
W/m2k |
W/m2k |
|||
Header |
0.0638 |
0.0946 |
4.60438 |
1.31648 |
Left Jamb |
0.1397 |
0.1826 |
16.32147 |
1.85603 |
Right Jamb |
0.1397 |
0.1826 |
26.14535 |
2.18867 |
Sill |
0.3608 |
0.0946 |
6.32962 |
1.72348 |
Glass Data of CSCW-N180 Stick Curtain Wall
Glass Data: CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU |
|||||||
Visible Light |
SHGC |
SC |
NFRC U-value |
STC |
|||
W/m3k(Argon) |
|||||||
T% |
R-out% |
R-in% |
Winter |
Summer |
|||
31.9 |
20.9 |
16.5 |
0.209 |
0.242 |
1.705 |
1.694 |
39.6 |
Benefit of of CSCW-N180 Stick Built Glass Walls
Certified performances in terms of air, water tightness and wind pressure.
Flexible for on-site installation
Cost efficient product compare to competition
Vast alternatives in custom solutions tailor made to the building
Enhancement of natural light
Increased static robustness, even in extreme natural phenomena
Minimum after sales service & maintaining
Increased comfort level
Recommended CAS Facade Products
Our facade products are designed to snap together perfectly, organically or with the help of couplers. This ensures a streamline design throughout your project. Below is a list of compatible products.
Persona a contactar : facade Cas, 0757 87655056
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de CSCW-N180 Stick Curtain Wall Buscar en la categoria : Varios / Descuento Buscar en la categoria : cscw, stick, curtain, wall, n180 |
Domingo 15 marzo 2015
TAYSAN MAKINA CO. SARL. Es una empresa que hace que la producción de tipos de máquinas totalmente automáticas y manuales de R para la fabricación de azúcar duro en cubos de Turquía y también máquinas para envasado de alimentos diversos y terrones de azúcar desde diez años de experiencia...
Taysan Makina Ltd
- taysanmakina
- 06370 - Ankara
- 0090 312 396 01 09
- 0090 546 610 06 05
Miércoles 14 septiembre 2016
Cantidad : 5000 - Precio : 50,00 €
Gate Valves (F7 Type) DIN Standard F7 Gate valves / (Length acc.to DIN EN 558-1,face to face series 26 ) DIN F7 Gate valve DIN Absperrschieber F7 DIN Válvulas de compuerta F7 DIN F7 šoupátko stavební délka dle DIN EN558-1 serie 26 DIN Standard F7 sluseventil (lengde iht. DIN EN 558-1...)
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Miércoles 14 septiembre 2016
Cantidad : 5000 - Precio : 50,00 €
Bellows Seal Stop Valves(Straight-Through Type) DIN Bellows Seal Stop Valve DIN Bellows Globe Valve DIN Faltenbalgventil Durchgangsform DIN Válvulas de fuelle DIN ventil uzavírací s vlnovcem přímý DIN Standard seteventil med belg (Rett løp modell) DIN Standardında Metal Körüklü...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935