CUCW-N142 Unitized Curtain Wall
Model No. CUCW-N142 is a self-designed, tested, and certificated unitized curtain walling system by CAS team. It is a cost efficient and performance unitised curtain wall system, which combines minimal aesthetics with structural stability. Its structural silicone glazing construction offers maximum transparency at the external surface of the facade. Modular units, including glazing panes, are prefabricated in workshop conditions and this results in a fast and economic installation with minimum manpower and tooling requirements. This construction mode, renders CUCW-N142 an ideal unitised system for high rise buildings,where meeting demanding deadlines is a prerequisite.
Overview of CUCW-N142 Unitized Curtain Wall
System |
Unitized Curtain Wall(Non-Thermal Break) |
Model No. |
CUCW-N142 |
Material |
Aluminum Alloy/Glass/Aluminum Sheet/Aluminum Composite Panel/Galvanized Sheet |
Glass Type |
Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak |
Cooperated Glass Brand |
Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/King/CNG/Ta iwanGlass |
Surface Treatment |
Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain |
Profile Brand |
6063-T5/6063-T6/6061-T6(Brackets) |
Thermal Profile |
Non-Thermal Break |
Standards |
In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO |
Application |
Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization |
System Customziation |
Available |
Data of CUCW-N142 Unitized Curtain Wall
Testing Data of CUCW-N142 Unitized Curtain Wall
Test |
Pressure |
Results |
Preloading(Clause 8.2.2 of AS/NZS4284: 2008) |
+1.46kpa |
No separation, plastic deformations, or deleteriousness was observed. |
-1.90kpa |
||
Preliminary Water Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284: 2008) |
+438kPa |
There were no leaks. |
Preliminary Water Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284: 2008) |
219-438-219 (Pa) |
There were no leaks. |
292-584-292 (Pa) |
||
438-876-438 (Pa) |
||
Structural Test at Serviceability Limit State Wind Pressure (Walls)(Clause 8.3 of AS/NZS 4284: 2008) |
+1.46kpa |
During the structural test at SLS wind pressure, the deflections of all related members were within the allowable deflection limits. |
-1.90kpa |
||
Air Infiltration Test (Clause 8.4 of AS/NZS 4284: 2008) |
+/-150Pa |
The rate of air leakage of the specimen was within the allowable values. |
Water Test under Static Water Test under Static 4284: 2008) |
+438Pa |
There were no leaks. |
Water Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284: 2008) |
219-438-219 (Pa) |
There were no leaks. |
292-584-292 (Pa) |
||
438-876-438 (Pa) |
||
Structural ProofTest at Ultimate Limit State Wind Pressure (Wells) (Clause 8.8 of AS/NZS 4284: 2008) |
+2.26kpa |
No collapse of the test specimen was observed under the specified pressure. |
-2.94kpa |
||
Seal Degradation Test(Clause 8.10 of AS/NZS 4284: 2008) |
219-438-219 (Pa) |
No water leakage was observed. |
292-584-292 (Pa) |
||
438-876-438 (Pa) |
Thermal Data of CUCW-N142 Unitized Curtain Wall
NFRC Procedures |
NFRC100SB, NFRC200-2010, and NFRC500-2010 |
Software Tools |
THERM 7.4.3.0 and WINDOW 7.4.6.0 |
Configuration |
6 CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU |
Panel Dimension |
1505mm Wide 2945mm High |
Frame |
Painted Aluminum |
Panel U-value |
2.765W/m2k |
Visible Light Transmission |
0.246 |
SHGC |
0.179 |
Frame Data of CUCW-N142 Unitized Curtain Wall
Parts Location |
Frame Area/m2 |
Edge Area/m2 |
U-Value(Frame) |
U-Value(Edge) |
W/m2k |
W/m2k |
|||
Header |
0.058 |
0.086 |
4.1858 |
1.1968 |
Left Jamb |
0.127 |
0.166 |
14.8377 |
1.6873 |
Right Jamb |
0.127 |
0.166 |
23.7685 |
1.9897 |
Sill |
0.328 |
0.086 |
5.7542 |
1.5668 |
Glass Data of CUCW-N142 Unitized Curtain Wall Manufacture
Glass Data: CLR-TDE33D 8mm HS #2 + 12AR + CLR 10mm HS IGU |
|||||||
Visible Light |
SHGC |
SC |
NFRC U-value |
STC |
|||
W/m3k(Argon) |
|||||||
T% |
R-out% |
R-in% |
Winter |
Summer |
|||
29 |
19 |
15 |
0.19 |
0.22 |
1.55 |
1.54 |
36 |
Benefit of CUCW-N142 Unitized Custom Curtain Wall
Guaranteed waterproofness & airtightness
Great quality control from factory
Lower on-site installation cost
Shorter project schedule
Enhancement of natural light
Increased static robustness, even in extreme natural phenomena
Minimum after sales service & maintaining
Increased comfort level
If you want to know more details of unitised system facade, please visit our website.
Persona a contactar : facade Cas, 0757 87655056
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de CUCW-N142 Unitized Curtain Wall Buscar en la categoria : Varios / Descuento Buscar en la categoria : cucw, unitized, wall, curtain, n142 |
Miércoles 14 septiembre 2016
Cantidad : 5000 - Precio : 50,00 €
Bellows Seal Stop Valves(Straight-Through Type) DIN Bellows Seal Stop Valve DIN Bellows Globe Valve DIN Faltenbalgventil Durchgangsform DIN Válvulas de fuelle DIN ventil uzavírací s vlnovcem přímý DIN Standard seteventil med belg (Rett løp modell) DIN Standardında Metal Körüklü...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Sábado 18 julio 2015
Especificaciones: Tamaño de hoja: 210mm x 297mm, Internacional A4 Calidad: 100% importado de pulpa de madera virgen Blancura = 102-104%, blanco natural Capacidad: Copying100ppm alta velocidad, Laser Capaz, Especificaciones de chorro: Tamaño de hoja: 210mm x 297mm, Internacional A4 Calidad...
PAPERY (THAILAND )CO LTD
- 10400 - Bangkok
- 098765443533
Miércoles 23 marzo 2016
BUBBLE FOOTBALL BUBBLE FOOTBALL SUITS ORDER-8 BALLS £1,160.00 SKU: ZS6 Bubble football is a game played by kids as well as grown-ups. It one of the most ridiculous fun games today. It is always fun when you bash into each other laughing yourselves out. As crazy as its name suggests...
bubble-football-uk
- EC1A 2BN - London
- 44 7470 016574