Bienes de equipo

EMI Test Receiver

EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. The EMI-9KB EMI receiver is made of full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPR15: 2018, CISPR16-1, GB17743, FCC, EN55015 and EN55022.

System Configurations:
• EMI-9KC Test System includes: EMI-9KC EMI Receiver built-in Attenuator (9K-1GHz), LISN Artificial Network Power, CDNE-M316 Coupling/Decoupling Network for Emission, Isolation Transformers, Attenuator and cables.
• EMI-9KB Test System includes: EMI-9KB EMI Receiver (9K-300MHz), LISN Artificial Network Power, CDNE-M316 Coupling/Decoupling Network for Emission, Isolation Transformers, Attenuator and cables.
• EMI-9KA Test System includes: EMI-9KA EMI Receiver (9K-30MHz), LISN Artificial Network Power, Isolation Transformers, Attenuator and cables.

Option instruments to work with the EMI-9KC, EMI-9KB and EMI-9KA EMI receivers:
LISUN LSP-500VARC/LSP-1KVARC Pure Sine Wave AC Power Source for EUT
LISUN SDR-2000B Magnetic Shielding Cabinet for the EMI Receiver System
LISUN VVLA-30M Three Loop Antenna to test 9k-30MHz radiation
LISUN AB-CLP Absorbing Clamp to test the home applications & motor tools
LISUN VOL-CP RF Current Probe to the conducted disturbance voltage

Specification:
• Detection frequency range: 9kHz~1GHz (EMI-9KC), 9kHz~300MHz (EMI-9KB), 9kHz~30MHz (EMI-9KA)
• Frequency stability: 1×10^-6
• Frequency resolution: (9kHz~150kHz) 30Hz; (150kHz~30MHz) 1kHz
• Test Tolerance: ±2 dB
• Measure and Detection method: PK, QP and AV
• Measure range: 20dBμV~140dBμV
• Frequency scanning step frequency: 20Hz~2MHz
• Sweep bandwidth:200Hz; 9kHz; 120kHz
• Connect PC via USB cable and software can run on Win7, Win8, Win10, Win11

What is EMI ?
EMI (Electromagnetic Interference) is electronic noise that interferes with cable signals and reduces signal integrity. EMI is usually generated by electromagnetic radiation sources such as motors and machines. Electromagnetic Interference has two types: conducted interference and radiated interference. Conducted interference refers to the coupling (interference) of signals on one electrical network to another electrical network through a conductive medium. Radiated interference refers to the interference source coupling (interference) its signal to another electrical network through space.

How to test EMI Interference?
Electromagnetic disturbance that degrades the performance of electrical equipment or electronic device, works abnormally or fails. It can be divided into conducted interference test and radiated interference test. LISUN EMI-9KB is an automatic EMI receiver system for EMI (Electromagnetic Interference) radiation conduction or conducted emissions testing. It can do both conducted interference test and radiated interference test.

What's the difference between EMI and EMS?
EMC (Electro Magnetic Compatibility) literally translates to “electromagnetic compatibility”. EMI (Electromagnetic Interference) “Electromagnetic Interference” can be understood as attack type. There are two types of EMI, conducted interference and radiated interference. EMS (Electro Magnetic Susceptibility) literally translates to “electromagnetic sensitivity”, which we can understand as defensive type, which means the ease of performance degradation due to electromagnetic energy.

Noted: According to latest CISPR15: 2018 standard, you need to use CDNE-M316 (Coupling/Decoupling Network for Emission) instead the CDN. The CDNE-M316 working with EMI receiver system is equivalent to test radiated electromagnetic disturbance of electric lighting appliance with frequency from 30M to 300mHz.

Ubicación : 113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, 201802 Shanghai,
Persona a contactar : He Rachel, +15 3 17 38 39 97

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
EMI Test Receiver

Buscar en la categoria : Bienes de equipo
Buscar en la categoria :
test, receiver
Taiwán 407 Telefonía
Band Saw -Way Train Industries Co., Ltd.

Jueves 28 agosto 2014

Precise Vision for a Future of Precision Our metal cutting band saws range from the smallest 4" hand held band saw to medium size 7", 8", 9", and 10" professional bandsaws, up to the heavy duty 13", 16", 18" and 20" industrial band saws. Way Train products have a wide range of applications...

S&J

  • 407 - Taichung , Taiwan
  • 886437038989
Malvinas (Islas 555555 Ropa
Foto no disponible

Jueves 10 septiembre 2015

Established in 1993, Jianlian Aluminums Co., LTD. [at Dali Xiebian, Nanhai District, Foshan City, China] is a professional manufacturer and exporter specializing in homecare rehabilitation products. The company is sitting on 3.5 Acre of land with 9000 square meters building area...

Jianlian Homecare Products Co., Ltd

  • 555555 - Guangdong
  • +86 13724935495
Eslovaquia 81102 B2B Servicios
Software de casino online

Viernes 07 marzo 2014

XPG Live Dealer Casino ofrece una plataforma excepcional con la ayuda de la cual sus clientes podrán disfrutar de la atmosfera del casino real con los juegos de Casino y Poker a través el Internet. Transmisión pasa en vivo desde los estudios europeos. Los juegos representan unos...

XPG Live Casino

  • 81102 - Bratislava
  • +442035190908