Varios / Descuento

Factors Affecting the Performance of C18 HPLC Columns

Physical properties of the chromatographic column could affect the performance of C18 HPLC columns.

Performance factors of C18 HPLC columns:

Silica gel purity
Class A silica gel has high residual silica hydroxyl with a negative charge and high metal content on the acidic surface, which leads to trailing of alkaline compounds.
Due to the low metal content and high silica hydroxyl pKa of class B silica gel, tail dragging of alkaline compounds does not occur.

Performance factors of C18 HPLC columns:

Column size
Short column – short running time, low column pressure
Long column – high resolution, long running time
Narrow diameter column – detector has high sensitivity

Performance factors of C18 HPLC columns:

Particle shape and size
When the mobile phase with high viscosity is used, the spherical particles can reduce the column pressure and prolong the life of the column. Smaller particles have higher column efficiency but can cause column pressure to be too high.

Performance factors of C18 HPLC columns:

Surface area and aperture
The high surface area has strong retention capacity, column capacity and separation degree for separating multi-component samples. Low surface area fillers usually reach equilibrium quickly and are particularly important for gradient leaching.

Ubicación : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Persona a contactar : Bruce Lu, +86 29 89284429

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
Factors Affecting the Performance of C18 HPLC Columns

Buscar en la categoria : Varios / Descuento
Buscar en la categoria :
hplc, columns, performance, factors, affecting
Thailandia 10110 Materias primeras
De alta calidad de alambre de cobre Chatarra 99,99% Milberry

Tuesday 14 July 2015

Cantidad : 15000MT - Precio : 2500euro

De alta calidad de alambre de cobre Chatarra 99,99% Milberry somos proveedores de alta calidad alambre de cobre Chatarra 99,99% Milberry especificación Cobre CHATARRA DE ALAMBRE, (Millberry) 99,78% con una pureza de 99,78% min. 99.78% Max. COBRE: 99, 9% CARBONO: 0,03% COBLET: ...

CA PRODUCTS CO, LTD

  • 10110 - bangkok
  • +66 2 62 61 74 11
  • +66 9 62 91 74 69
Hong Kong 999077 Bienes de equipo
Gas detector for Car/Vehicle

Wednesday 06 August 2014

Cantidad : 9999pcs - Precio : negotiation

Gas detector for Car/Vehicle: Type: ACG-1 Detector+Control Panel Kit 1.Sensor: Semiconductor sensor 2.Detecting Gas: Natural gas 3.Enivronmental parameter: temperature: -20Centidegree~+105 Centidegree RH: ≤85% (Non-condensing) 4.Alarm method: Flasher and Sounder 5.Alarm Volumn: ...

Alertech Electronics(H.K.) Co.,Ltd

Maillots de bain filles licence.

Saturday 12 July 2014

Cantidad : 5000 - Precio : 1,50 euros

Bonjour, Vends maillots de bain filles licence High School Musical. Taille: 116-122-128-134-140-146-152-158-164-170. Prix 1,50 euros par 500 pièces. Mail. nekortex@gmail.com Mobile. 06.52.83.92.08 Mr Ben. Ubicación : 18 rue d'albert, 95140 Garges les gonesses, Persona a contactar ...

SARL DTR

  • 95140 - Garges les gonesses
  • 06 52 83 92 08