Fire Resistant Control Cable (2-4cores) 300-500V
Fire resistant control cable 2-4 cores 300/500V features Mica tape twisted with copper conductor, the cable refers as multiple cores Cu/MicaXLPE(PVC)/LSZH 300/500V to basic standard BS7211. The function of mica is to prevent burning when cables catching fire. The cable can maintain the integrity of the electric circuit and continue to work for a period of time when exposed to fire. The sheath is compound material LSFH low smoking free holagen which has little smoking and no toxic gas emission which reduces the damage to the people and equipment. These fire rated control cables we supplied are twisted two layers of mica tape with 80% overlap rate which achieves a good performance of fire resistance.
Fire Resistant Control Cable (2-4cores) 300-500V Parameter
Conductor |
rated voltage 300/500v |
||||||
|
Without Earth Conductor |
With Earth Conductor |
|||||
No. of Core X Cross Section |
No./Nominal Diameter of Strands |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Overall Diameter |
Approx. Weight |
Nominal Overall Diameter |
Approx. Weight |
No*mm虏 |
No./mm |
mm |
mm |
mm |
kg/km |
mm |
kg/km |
2 Cores |
|||||||
2x1.5 |
7/0.53 |
0.5 |
0.5 |
7.7 |
70 |
8.2 |
80 |
2x2.5 |
7/0.67 |
0.5 |
0.5 |
8.8 |
100 |
9.6 |
120 |
2x4 |
7/0.85 |
0.5 |
0.5 |
9.8 |
140 |
10.5 |
170 |
3 Cores |
|||||||
3x1.5 |
7/0.53 |
0.5 |
0.5 |
8.7 |
90 |
10.5 |
100 |
3x2.5 |
7/0.67 |
0.5 |
0.5 |
9.5 |
125 |
10.7 |
150 |
3x4 |
7/0.85 |
0.5 |
0.5 |
11.5 |
180 |
12.5 |
220 |
4 Cores |
|||||||
4x1.5 |
7/0.53 |
0.5 |
0.5 |
10.3 |
105 |
12.2 |
120 |
4x2.5 |
7/0.67 |
0.5 |
0.5 |
11 |
155 |
13 |
190 |
4x4 |
7/0.85 |
0.5 |
0.5 |
12.5 |
255 |
13.5 |
270 |
Description of Fire Resistant Control Cable (2-4cores) 300-500V
Rated voltage: 300/500V
Basic standard: BS 7211
Conductor: bare annealed copper wire, stranded wire to IEC(EN) 60228 class 2
Fire lyer: Mica glass tape
Insulation: PVC (XLPE)
Sheath: LSZH compound to BS 7655-6.1
Operating temperature range (fixed state): -30°C – +90°C
Operating temperature range (mobile state): -20°C – +50°C
Min bending radius: 6 times of Overall Diameter
Insulation resistance: 20 MΩ x km (at 20°C)
Short circuit temperature: 250°C
Circuit Integrity |
IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); |
|
CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); |
|
NF C32-070-2.3(CR1) |
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; |
|
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); |
|
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30- |
|
004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; |
|
CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; |
|
CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; |
|
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases |
NES 02-713; NF C 20-454 |
Application Of Fireproof Electrical Cable (2-4cores) 300-500V
The cables are designed for facilities where keeping and maintaining integrity of the electrical circuit is critical in power supply system.
The cables are widely used in underground tunnels, emergency lightings, fire alarm systems, control and power circuits, power stations, lifts, escalators, and high-rise buildings.
As one of fire resistant cable suppliers, we can offer kinds of 2 core fire resistant cable for sale, if you have needs, please contact us.
There are many flexible cable manufacturers in China, but we are one of the best choices for you.
Persona a contactar : Kwok Peter, +86 0757 85682768
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de Fire Resistant Control Cable (2-4cores) 300-500V Buscar en la categoria : Varios / Descuento Buscar en la categoria : control, 4cores, resistant, cable, fire, 500v |
Domingo 23 septiembre 2012
Cantidad : Minimum Or - Precio : T/T in advance, L/C
This Auto Stainer provides fast, easy and stable staining process for staining sputum specimen (for detecting AFB, Tubercle Bacillus) according to Ziehl-Neelsen staining method by automated system control and slide heating system. This new innovated stainer features advanced functions...
Dagatronics Corporation
- 411-808 - Geonggi-do
- +82 3 19 16 80 05
Sábado 15 septiembre 2012
Cantidad : Minimum Or - Precio : T/T in advance, L/C
This Hematology Auto Stainer provides fast, easy and stable staining process for staining blood according to Wright, Wright-Giemsa and May-Grünward staining method by automated system control. This new innovated stainer features advanced functions and performances over manual staining...
Dagatronics Corporation
- 411-808 - Geonggi-do
- +82 3 19 16 80 05
Jueves 01 agosto 2013
Cantidad : moq:1pcs - Precio : USD406.4
A high-sensitivity Premium Compact Design Full HD Memory Camcorder equipped with Wi-Fi technology for easy Live Monitoring, Video E-mail and Home Detection Monitoring (Auto Photo E-mail) using Android phones/tablets, iPhone, iPad or PC. Just install a free app on your Smartphone...
AC Electronic Ltd
- 999077 - HongKong
- +85 2 23 25 18 67
- +86 13501567844