Flash Column Chromatography

Flash column chromatography is an alternative to long column chromatography developed in 1978.

This method aims to separate the components from the mixture and thereby purify it. It is built from existing long column chromatography techniques and is time-consuming and often unsatisfactory. Briefly, flash column chromatography allows the sample to pass through a gel-filled column that separates the sample.

Still and chromatographic founder Still and colleagues have been using medium- and high-column chromatography instead of long-column chromatography. They decided to combine the two to overcome the shortcomings of long column chromatography and low recovery.

The gel originally used to fill the column was silica gel, which is still widely used. They use gas pressure to push the solvent through a silica gel column and compress the column. The sample is then applied and the sample is passed through the column using the same (may be different, but usually the same) solvent. The purified components or fractions are then collected and the entire process takes approximately 5 – 10 minutes. Usually, a small portion first appears and most of it elutes at the end. The collected fractions were subjected to original analysis by thin layer chromatography (TLC) plates.

Silica gel column chromatography has been widely used in organic chemistry since its inception. However, the guidelines are often loose, driven by personal experience, or not well translated when settings are changed. However, some things are still true. Increasing the sample size will result in a lower resolution. Compared to high-performance liquid chromatography (HPLC), the resolution of flash column chromatography is already moderate, but sufficient for adequate separation, so an increase in the number will only worsen the situation. Second, the optimum flow rate depends on the length and width of the column and the nature of the gel. This is due to the number of plates available, for example, longer and narrower columns will provide more theoretical plates, affecting the flow rate. Finally, the resolution is affected by the stationary phase. It provides better resolution if the stationary phase or the gel arranged on the column is more uniform and has a smaller particle size. The smaller the particle size, the larger the surface area and the higher the resolution.

Manipulating all of these factors to optimize component purity or recovery can be quite complicated because they interact, but have different effects when tested independently. For example, mobile phase selectivity has the greatest impact on resolution, but it depends on column capacity. This, in turn, is affected by the solvent chosen.

Therefore, you need to test or calculate the settings used in the flash column chromatography before starting any real experiments. If you have data from TLC, you can calculate the optimal settings without having to test any of the flash column settings. The low thin layer chromatography delay factor (Rf) provides better separation. Using such data, the amount of solvent required can be calculated because they are inversely proportional to each other and both are related to the column void volume (solvent in the column before sample loading).

In the original method, it is very important to prevent the column from drying out. However, a more user-friendly alternative has been developed since then, called dry column flash chromatography. This method has been adopted by first-time students while still producing better results comparable to analyzing TLC quality. The principle is the same, but the column contains dry silica gel. The powdered xerogel was filled into the column by suction, finally obtaining a uniform bed of about 1 cm for the solvent and the sample. The column was also eluted by aspiration and dried after each fraction.

Ubicación : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Persona a contactar : Bruce Lu, +86 29 89284429

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
Flash Column Chromatography

Buscar en la categoria : Varios / Descuento
Buscar en la categoria :
flash, chromatography, column
Turquía 84000 Vehiculos
ALTERNATİVE JCB spare parts 3cx an 4cx model

Viernes 15 diciembre 2017

online katalogOEM PART NO DESCRİPİTİON 66072 Crown Wheel and Pinion FOR CARRARO 13X30 66941 Crown Wheel and Pinion 15x37 2277448 CATERPİLLAR AİR FİLTER OUTER 2277449 CATERPİLLAR AİR FİLTER İNNER 01/117901 FAN BELT 01/124403 FAN BELT 01/124404 02/100073 Oil Filter Canister Type, MEDİUM...

ANAC MAKINA CO LTD STI

  • 34800 - İSTANBUL
  • +905069691531
  • +9005069691531
Taiwán 42742 Higiene / salud
Eco lavandería bola

Lunes 26 noviembre 2012

Cantidad : 10000 - Precio : Eco-linge Ball

• Protección del medio ambiente • Protección de la piel de la salud • Fibra protección • Limpieza de material de la frugalidad • Ahorro de agua • Ahorro de electricidad • Lavarse efecto • Blanqueo efecto • Efecto bactericida • Anti-enredo efecto • Fibra efecto suavidad Ubicación ...

Yame International Taiwan

Turquía 06070 Bienes de equipo
Foto no disponible

Jueves 17 enero 2013

Cantidad : 18MT - Precio : 70,00 €

Abajo se encuentra la cita y nuestra especificación. Pellets de madera... ... 95Euros Carbón de madera... 100Euros Pellets de cáscara, girasol... 80Euros Leña... 75Euros Briquetas... ... 200Euros ESPECIFICACIONES TÍPICAS * Cortado y dividido-(20-30 cm) * Humectada % 20 En...

NCF COMPANY

  • 06070 - IZMIR
  • 00905428841676