Hart to Modbus Gateway
Description
Parameters
|
Name |
Description |
|
Gateway Power |
9~30VDC |
|
Modbus Interface |
RS-232/RS-422/RS485 |
|
HART Interface |
HART Digital Signal |
|
Consumption |
1W |
|
Interface Input Inpedance |
≥5KΩ |
|
HART Interface Voltage Insulation Value |
50VDC |
|
HART Output Amplitude |
500mVpp (500Ω) |
|
Humidity Range |
(5~95)%RH |
|
Working Temperature |
-20℃~70℃ |
|
Storage Temperature |
-20℃~70℃ |
|
Isolation Voltage |
Modbus and HART Interface, 500VAC |
|
Protection Level |
IP20 |
|
EMC |
GB/T 18268.1-2010 GB/T 18268.23-2010 |
|
Weight |
0.2kg |
|
Construction Material |
Housing: ABS/PA66; Clip: POM; Coating: Polyester Epoxy Resin |
|
HART Master Type |
The Primary or Secondary Master can be Selected. |
|
HART Network Topology |
Support HART Point to Point or Multi-Drop Working Mode, and can Connect 15 Instruments at most |
|
Burst Mode(Burst) |
Support HART Slave Device Burst Mode |
|
HART Customized Command |
Support 100 HART CUSTOMIZED COMMANDS AT MOST, EACH 5000 BYTES FOR HART INPUT OUTPUT ZONE AND DATE BUFFER ZONE. |
|
HART Modem Mode |
Gateway can be set as HART Modem Mode. |
|
HART Sampling Resistor |
Optional for Internal Sampling Resistor or External Resistor |
|
Modbus Baud Rate |
300,600,1200,2400,4800,9600,19200,38400,57600,115200bps, optional |
|
Modbus Communication Mode |
Support Modbus Slave RTU and ASCII Communication Mode |
|
Modbus Function Code |
0x03/0x04/0x06/0x10 |
FAQ
Q: Can I get a free electronic manual?
A: Yes, if you want it, please contact us.
Q: How many modes does it work?
A: The HART to Modbus gateway has four working modes, respectively is normal workingmode, HART modem mode, configuration mode and debugging mode. Gateway mode may be selected by two-bit DIP switch on the gateway.
Q: Can you provided OEM service?
A: Yes, we can, such as communication board, we can also provided fieldbus development toolkit
jiang.yuhang@microcyber.cn +86 18304037682
Persona a contactar : Yvette Jiang, +86 18304037682
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
|
Esta página es acerca de los importadores y exportadores de Hart to Modbus Gateway Buscar en la categoria : Informática Buscar en la categoria : gateway, modbus, hart |
Tuesday 06 January 2026
♦ Functions * 2-channel temperature monitor * 1-channel fan speed control * Run time function * Fan fault alarm * Temperature fault alarm * Fan speed storage function * Auto fan speed control → 40°C: Low 50°C: Middle 60°C: High * Immediate visual indication of Fan/HDD...
Tengda Electronics Limited
- simeongao
- 518102 - hongkong
- +85 2 21 10 18 65
Tuesday 08 September 2015
Ubicación : Workshop 6S-V,Valiant Ind.Bldg.,2-12 Au Pui Wan St, Fo Tan, Hong Kong, 852 Fo Tan, Persona a contactar : Ella Zhan, +85 2 26 75 75 58
ZT Technology Group Ltd.
- ellazhan
- 852 - Fo Tan
- +85 2 26 75 75 58
Tuesday 11 February 2014
Cantidad : SUPERIEURE - Precio : +00.00 US
JEFE una estructura de comercio, estoy facultado y les traigo este anuncio. Empresa industrial con sede en Costa de Marfil está buscando potenciales clientes internacionales para la venta de productos de calidad siguientes: Cacao en masa -El cacao en polvo -Manteca de Cacao ...
KTFSERVICE-DYNAPHARM CI
- 00225 - ABIDJAN
- +22 5 58 39 51 81





