Informática

High Precision Spectroradiometer Integrating Sphere System

Precio : 1,00 €

Basic Info.

Model NO.

LPCE-2

After-sales Service

Perfect

Warranty

24months

Trademark

LISUN

Origin

China

Product Description

LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED's quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84, CIE-13.3, IES LM-79-19, Optical-Engineering-49-3-033602, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IESNA LM-63-2, IES-LM-80 and ANSI-C78.377, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS-9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and A molding integrating sphere with holder base. This sphere is more round and the test result is more accruacy than the traditional integrating sphere.

Measures:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF
• Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic
• LED Light Decay Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.

Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82

High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufactory or General Test Lab):
High Precision CCD Spectroradiometer (LMS-9000C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure

Specification:
• Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm
• Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (under Standard A Lamp)
• Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5%
• Stray light: <0.015%(600nm) and <0.03%(435nm)<br /> • Integration Time: 0.1~10,000ms
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

LISUN Model LMS-9000C LMS-9000CUV-VIS LMS-9000CVIS-NIR
Wavelength 350-800nm 200-800nm 350-1050nm

Scientific Grade LPCE-2(LMS-9500C) System Configuration (It is suitable for the Big & Middle Manufactory or Third Party Test Lab):
Scientific Grade CCD Spectroradiometer (LMS-9500C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050C), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9500C) Scientific Grade CCD Spectroradiometer Integrating Sphere System Brochure

Specification:
• CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector
• Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Sample scanning steps: ±0.1nm
• Accuracy of chromaticity coordinate (Δx, Δy): ±0.0015 (under Standard A Lamp)
• Correlated color temperature CCT: 1, 500K~100, 000K, CCT accuracy: ±0.2%
• Color rendering index range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear Accuracy: ±0.2%
• Stray light: <0.015%(600nm) and <0.03% (435nm)<br /> • Integration time: 0.1ms-60s
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10 and Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF

LISUN Model LMS-9500C LMS-9500CUV-VIS LMS-9500CVIS-NIR
Wavelength 350-800nm 200-800nm 350-1050nm
Ubicación : 113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, 201802 Shanghai,
Persona a contactar : Rachel He, 860015317383997

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
High Precision Spectroradiometer Integrating Sphere System

Buscar en la categoria : Informática
Buscar en la categoria :
sphere, system, precision, high, spectroradiometer, integrating
Foto no disponible

Saturday 30 August 2008

Nous proposons un lot de : - produits et composants informatiques, - équipements magasin (fabrication allemande) : comptoir, gondoles professionnelles double face sur roulettes, étagère murale (même type que gondoles). Photos sur demande.Ubicación : , Luxembourg, Persona a contactar ...

ATTIS TECHNOLOGY

  • attis
  • - Luxembourg
  • 00352621235422
Bolívia none Varios / Descuento
Foto no disponible

Tuesday 10 July 2007

Cantidad : 2000 Tons

we sell diferents grains of high cuality : Quinoa, Cañahua ,Amaranth, Maca and his derivates like pops, flakes, fluor.Ubicación : Urbanizacion"Los Pinos" Zona Norte, none Oruro, Persona a contactar : Jean-marie Galliath, +59 1 25 28 51 88

SONAPTO S.R.L.

  • sonapto
  • none - Oruro
  • +59 1 25 28 51 88
  • +59 1 70 42 43 19
Foto no disponible

Saturday 05 May 2007

Cantidad : 1kg - Precio : 3$

We export dried herring with high quality to Russian, Ukraina, Korean, Malaysian, Hong Kong Markets... Our company is one of VASEP (VietNam Association of Seafood Exporters and Producers) members. If you interested in my products please contact us, we're willing to send you our samples...

DKPT SEAFOOD.,LTD