High Precision Spectroradiometer Integrating Sphere System
LPCE-2 Integrating Sphere Spectroradiometer LED Testing System is for single LEDs and LED lighting products light measurement. LED's quality should be tested by checking its photometric, colorimetric and electrical parameters. According to CIE 177, CIE84, CIE-13.3, IES LM-79-19, Optical-Engineering-49-3-033602, COMMISSION DELEGATED REGULATION (EU) 2019/2015, IESNA LM-63-2, IES-LM-80 and ANSI-C78.377, it recommends to using an array spectroradiometer with an integrating sphere to test SSL products. The LPCE-2 system is applied with LMS-9000C High Precision CCD Spectroradiometer or LMS-9500C Scientific Grade CCD Spectroradiometer, and a-molding integrating sphere with holder base. This sphere is more round and the test result is more accruate than the traditional integrating sphere.
Measures:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant Wavelength, Color Purity, CRI, CQS, TM-30 (Rf, Rg), Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power, WPE, EQE, EEI, Energy Efficiency Class, Pupil Flux, Pupil Flux Efficiency, Pupil Factor, Cirtopic Flux, Plant Growth Lamp PAR and PPF
• Electrical: Voltage, Current, Power, Power Factor, Displacement Factor, Harmonic(Optional)
• LED Light Aging Test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS time, Power Factor VS time, Current VS time and Flux Efficiency VS time.
Option: The LPCE-2(LMS-9000C) or LPCE-2(LMS-9500C) work with a IS-1.5MT Constant Temperature Integrating Sphere and TMP-8 Multiplex Temperature Tester can fully meet IES LM-82
High Precision LPCE-2(LMS-9000C) System Configuration (It is suitable for the Middle & Small Manufacturer or General Test Lab):
High Precision CCD Spectroradiometer (LMS-9000C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050B/LS2050C/LS2012), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detailed PDF here: LPCE-2 (LMS-9000C) High Precision CCD Spectroradiometer Integrating Sphere System Brochure
Specification:
• Spectral Wavelength Accuracy: ±0.3nm, Wavelength Reproducibility: ±0.1nm
• Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002 (under Standard A Lamp)
• Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Luminous Flux Range: 0.01-200,000lm; Photometric linear Accuracy: ±0.5%
• Stray light: <0.015%(600nm) and <0.03%(435nm)<br />
• Integration Time: 0.1~10,000ms
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can run in Win7, Win8, Win10, Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometry, Colorimetry and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF
| LISUN Model | LMS-9000C | LMS-9000CUV-VIS | LMS-9000CVIS-NIR |
| Wavelength | 350-800nm | 200-800nm | 350-1050nm |
Scientific Grade LPCE-2(LMS-9500C) System Configuration (It is suitable for the Big & Middle Manufactory or Third Party Test Lab):
Scientific Grade CCD Spectroradiometer (LMS-9500C), Optical Fiber (CFO-1.5M), Digital Power Meter (LS2050C), DC Power Source (DC Series), AC Power Source (LSP-500VARC or LSP-500VARC-Pst), Integrating Sphere (IS-1.5MA and IS-0.3M), Standard Light Source (SLS-50W and SLS-10W), 19 Inch Cabinet (CASE-19IN). You can download the detail PDF here: LPCE-2 (LMS-9500C) Scientific Grade CCD Spectroradiometer Integrating Sphere System Brochure
Specification:
• CCD detector: Hamamatsu TE-cooled (Temp: -10°C ±0.05°C) high sensitivity back-thinned detector
• Spectral wavelength accuracy: ±0.2nm, Resolution: ±0.1nm, Sample scanning steps: ±0.1nm
• Accuracy of chromaticity coordinate (Δx, Δy): ±0.0015 (under Standard A Lamp)
• Correlated color temperature CCT: 1, 500K~100, 000K, CCT accuracy: ±0.2%
• Color rendering index range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear Accuracy: ±0.2%
• Stray light: <0.015%(600nm) and <0.03% (435nm)<br />
• Integration time: 0.1ms-60s
• It can measure the temperatures inside and outside of integrating sphere
• Flux testing method: spectrum, photometric and spectrum with photometric revision
• The system includes the auxiliary lamp device and the software includes self-absorption function
• It can measure the temperatures inside and outside of integrating sphere
• Connect with PC via USB cable. The English version software can be run in Win7, Win8, Win10, Win11 (The driver was Certificated by Microsoft)
• The LM-79 Photometric, Colorimetric and Electricity report can be exported PDF and LED Optical Maintenance test report can be exported Excel or PDF
| LISUN Model | LMS-9500C | LMS-9500CUV-VIS | LMS-9500CVIS-NIR |
| Wavelength | 350-800nm | 200-800nm | 350-1050nm |
Persona a contactar : He Rachel, +15 3 17 38 39 97
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
|
Esta página es acerca de los importadores y exportadores de High Precision Spectroradiometer Integrating Sphere System Buscar en la categoria : Bienes de equipo Buscar en la categoria : system, sphere, spectroradiometer, high, integrating, precision |
Thursday 15 January 2009
Desiccated Coconut Desiccated coconut high fat fine and mediumg grades: - Moisture: 3% max, - FFA: 0.3 % max, - Oil content: 62% min, - Free from ecoli or bactereia, no foreign matterUbicación : 20/5 Dinh Bo Linh str Binh Thanh Distr, 84 Ho Chi Minh, Persona a contactar : Smith Nguyen...
vietdelta industrial co.,ltd
- smithvn
- 84 - Ho Chi Minh
- 84(08)35114928
- 09 19 89 60 89
Saturday 05 May 2007
Cantidad : 1kg - Precio : 3$
We export dried herring with high quality to Russian, Ukraina, Korean, Malaysian, Hong Kong Markets... Our company is one of VASEP (VietNam Association of Seafood Exporters and Producers) members. If you interested in my products please contact us, we're willing to send you our samples...
DKPT SEAFOOD.,LTD
- dekhangphuthanh
- 84 - Ho Chi Minh
- +84 6 50 77 44 83
- +84 9 18 77 05 46
Thursday 25 March 2010
Cantidad : 500 - Precio : cif prix raisonable,
notre société a la recherche d'un fourniseur high tech produits Pc portable,(dell, toshiba, hp, acer,.......) neuf et camera digital cannon ,nikon...neuf a prix cif raisonable et compétativeUbicación : TUNISIE, 2045 TUNIS, Persona a contactar : Samira Sfs,
SFS PLANET
- godgod
- 2045 - TUNIS
- +21 6 93 22 63 65