High Signal Quality Pa Protocol Head Mounted Temperature Transmitter
NCS-TT106 temperature transmitter supports FF Hl, PROFIBUS PA and HART protocoIs and multiple temperature sensors. With independent R&D communication controller, it has become a fieldbus temperature transmitter with high performance.
|
Parameter |
Value |
|
Input Signal |
Resistance: PT100, CU50, CU100, 0~500Ω, 0~4000Ω Thermocouple: B, E, J, N, K, R, S, T Voltage signal: -100mV~100mV |
|
Channel |
Single |
|
RTD Wiring |
2-wire, 3-wire, 4-wire |
|
Bus Power |
9~32 VDC Current consumption (static): ≤14mA |
|
Bus Signal |
Communication ratio 31.25Kbit/s, current mode |
|
Isolation |
Between terminal and housing: 500 Vrms (707 VDC) |
|
Working Temperature |
-40℃~85℃ |
|
Humidity Range |
10%~90%RH |
|
Start Time |
≤5s |
|
Refresh Time |
0.5s |
|
EMC |
GB/T 18268-2000 |
|
Protection |
IP20 |
|
Signal Type |
Suggested Range (℃) |
Accuracy |
|
Resistance |
0~500Ω,0~4000Ω |
±0.05% |
|
PT100 |
-200~850℃ |
±0.2℃ |
|
PT1000 |
-200~850℃ |
±0.1℃ |
|
CU50 |
-50~150℃ |
±0.3℃ |
|
CU100 |
-50~150℃ |
±0.2℃ |
|
mV |
-100Mv~100mV |
0.05% |
|
B |
500℃~1810℃ |
±1.0℃ |
|
E |
-200℃~1000℃ |
±0.4℃ |
|
J |
-190℃~1200℃ |
±0.4℃ |
|
K |
-200℃~1372℃ |
±0.4℃ |
|
N |
-190℃~1300℃ |
±0.8℃ |
|
R |
0℃~1768℃ |
±1.0℃ |
|
S |
0℃~1768℃ |
±1.0℃ |
|
T |
-200℃~400℃ |
±0.4℃ |
|
mV |
-100Mv~100mV |
0.05% |
|
B |
500℃~1810℃ |
±1.0℃ |
|
E |
-200℃~1000℃ |
±0.4℃ |
|
J |
-190℃~1200℃ |
±0.4℃ |
|
K |
-200℃~1372℃ |
±0.4℃ |
|
N |
-190℃~1300℃ |
±0.8℃ |
|
R |
0°C ~ 1768°C |
±1.0°C |
|
S |
0 °C~ 1768°C |
±1.0°C |
|
T |
-200°C ~ 400°C |
±0.4°C |
welcome for your inquiry
jiang.yuhang@microcyber.cn +86 18304037682
Persona a contactar : Yvette Jiang, +86 18304037682
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
|
Esta página es acerca de los importadores y exportadores de High Signal Quality Pa Protocol Head Mounted Temperature Transmitter Buscar en la categoria : Bienes de equipo Buscar en la categoria : high, mounted, temperature, protocol, head, signal, quality |
Tuesday 01 April 2008
Cantidad : 2000
ROBO-TOTAL ORTHOPEDIC SYSTEM 1. ROBOTM CASTING TAPE 2. ROBOTM SPLINT 3. ROBOTM SOFT CAST 1-1. Stretch of the Product Stretch% length-way is one of crucial factors which decides the quality of the product, because it is required when the product is applied on body contour such as elbow and heel...
Tuesday 08 May 2012
Glass bead for sandblasting has the features of chemical stability, high mechanical intensity and hardness. They can be blasted onto the object surface with compressed air and can be used on compress glass, rubber, plastic, moulds with metal casting or compressing. The jetting balls...
ermakhim
- npkermakhim
- 125363 - Moskow
- +79 2 62 47 78 61
Friday 02 November 2007
We are a growing company, which is involved in food, vegetable processing and transformation is mainly what typify us. We do produce all about “antipasti” which is an Italian speciality conjugated to Mediterranean cuisine and culinary habits to give a succulent product range composed of...
medina
- alisiala2002
- 1124 - manouba
- +21 6 71 63 87 00
- +21 6 97 05 41 15