How to Prevent the HPLC Column Failure
The improper use of chromatographic columns will make the columns decrease or lose effectiveness.
Generally speaking, the columns always have problems at the end of them. If we can install a short column with the same stationary phase as the analysis column in front of analysis column, which is about five to thirty millimeter, the column will have a longer lifetime. Although the effectiveness with a short protective column is less, the final result is worthwhile.
The chromatographic columns' lifetime usually can reach two years and more when used correctly. One kind of the columns that are based on silica gel only can be used in pH values ranging from two to nine. Some adsorptive substances will be retained on the top of the column, especially some colored substances after used for a long time. For the new columns, the filler at the top of the columns may decrease and collapse, which reduce the column efficiency. And under this circumstance, the experimenters can restore the efficiency of the columns through adding fillers.
It is better to rinse the columns with eluent with strong eluting power after each work. When hydrochloric acid buffer solution is used as mobile phase, salt-free mobile phase is used to rinse. The compounds containing halogen family may corrode stainless . It is inappropriate to be exposed to them for a long time.The improper use of chromatographic columns will make the columns decrease or lose effectiveness.
Generally speaking, the columns always have problems at the end of them. If we can install a short column with the same stationary phase as the analysis column in front of analysis column, which is about five to thirty millimeter, the column will have a longer lifetime. Although the effectiveness with a short protective column is less, the final result is worthwhile.
The chromatographic columns' lifetime usually can reach two years and more when used correctly. One kind of the columns that are based on silica gel only can be used in pH values ranging from two to nine. Some adsorptive substances will be retained on the top of the column, especially some colored substances after used for a long time. For the new columns, the filler at the top of the columns may decrease and collapse, which reduce the column efficiency. And under this circumstance, the experimenters can restore the efficiency of the columns through adding fillers.
It is better to rinse the columns with eluent with strong eluting power after each work. When hydrochloric acid buffer solution is used as mobile phase, salt-free mobile phase is used to rinse. The compounds containing halogen family may corrode stainless . It is inappropriate to be exposed to them for a long time.
Persona a contactar : Bruce Lu, +86 29 89284429
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de How to Prevent the HPLC Column Failure Buscar en la categoria : Varios / Descuento Buscar en la categoria : column, hplc, prevent, failure |
Miércoles 14 septiembre 2016
Cantidad : 5000 - Precio : 100,00 €
Bellows Seal Stop Valves (Angle Type) DIN Angle Type Bellows Sealed Stop Valve DIN Bellows Seal Globe Valve DIN Faltenbalgventil Eckform DIN Válvulas de fuelle(Paso angular.) DIN ventil uzavírací s vlnovcem rohový DIN Standard seteventil med belg (Vinkel modell) DIN Standardında...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Viernes 06 febrero 2015
Chemical Name: DL-2-Amino-4-methylthiobutyric acid Structure Formula: Molecular Formula: C5H11N02S Molecular Weight: 149.21 Cas No: [59-51-8] Characteristics: White, crystalline platelets or powder having a characteristic odor. One g dissolves in about 30 ml of water...
Zhaocounty Granray Bioproducts Co.,Ltd
- 051530 - NanBaiShe
- 8631180826581
Viernes 15 noviembre 2024
Cantidad : 1
La freidora modelo GP son maquinas automáticas que dotadas de cintas auxiliares constituyen la mejor solución para la fabricación de pellets. - Construida en chapa de Acero Inoxidable AISI 304 segun normativa de maquinas y seguridadalimentaria publicadas por el ministerio de industria...
Mafrigarlo
- mafrigarlo
- 28970 - humanes de madrid
- 91 6971596