How to Prevent the HPLC Column Failure

The improper use of chromatographic columns will make the columns decrease or lose effectiveness.
Generally speaking, the columns always have problems at the end of them. If we can install a short column with the same stationary phase as the analysis column in front of analysis column, which is about five to thirty millimeter, the column will have a longer lifetime. Although the effectiveness with a short protective column is less, the final result is worthwhile.
The chromatographic columns' lifetime usually can reach two years and more when used correctly. One kind of the columns that are based on silica gel only can be used in pH values ranging from two to nine. Some adsorptive substances will be retained on the top of the column, especially some colored substances after used for a long time. For the new columns, the filler at the top of the columns may decrease and collapse, which reduce the column efficiency. And under this circumstance, the experimenters can restore the efficiency of the columns through adding fillers.
It is better to rinse the columns with eluent with strong eluting power after each work. When hydrochloric acid buffer solution is used as mobile phase, salt-free mobile phase is used to rinse. The compounds containing halogen family may corrode stainless . It is inappropriate to be exposed to them for a long time.The improper use of chromatographic columns will make the columns decrease or lose effectiveness.
Generally speaking, the columns always have problems at the end of them. If we can install a short column with the same stationary phase as the analysis column in front of analysis column, which is about five to thirty millimeter, the column will have a longer lifetime. Although the effectiveness with a short protective column is less, the final result is worthwhile.
The chromatographic columns' lifetime usually can reach two years and more when used correctly. One kind of the columns that are based on silica gel only can be used in pH values ranging from two to nine. Some adsorptive substances will be retained on the top of the column, especially some colored substances after used for a long time. For the new columns, the filler at the top of the columns may decrease and collapse, which reduce the column efficiency. And under this circumstance, the experimenters can restore the efficiency of the columns through adding fillers.
It is better to rinse the columns with eluent with strong eluting power after each work. When hydrochloric acid buffer solution is used as mobile phase, salt-free mobile phase is used to rinse. The compounds containing halogen family may corrode stainless . It is inappropriate to be exposed to them for a long time.

Ubicación : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Persona a contactar : Bruce Lu, +86 29 89284429

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
How to Prevent the HPLC Column Failure

Buscar en la categoria : Varios / Descuento
Buscar en la categoria :
hplc, prevent, failure, column
Turquía 84000 Vehiculos
ALTERNATİVE JCB spare parts 3cx an 4cx model

Viernes 15 diciembre 2017

online katalogOEM PART NO DESCRİPİTİON 66072 Crown Wheel and Pinion FOR CARRARO 13X30 66941 Crown Wheel and Pinion 15x37 2277448 CATERPİLLAR AİR FİLTER OUTER 2277449 CATERPİLLAR AİR FİLTER İNNER 01/117901 FAN BELT 01/124403 FAN BELT 01/124404 02/100073 Oil Filter Canister Type, MEDİUM...

ANAC MAKINA CO LTD STI

  • 34800 - İSTANBUL
  • +905069691531
  • +9005069691531
Taiwán 23511 Audio / video
VE-30RFM HDMI to RF Matrix Extender

Jueves 02 mayo 2024

▲VE-30RFM RX (Front / Rear) ▲VE-30RFM TX (Front / Rear)  VE-30RFM HDMI to RF Matrix Extender is designed to convert HDMI signal to HD digital TV signal based on DVB-T CATV signal, it uses 64QAM mode to realize the HD digital TV signal conversion and transmit via coaxial cables for...

Meicheng Audio Video Co., Ltd.

  • meicheng
  • 23511 - New Taipei City
  • 886 2 82280311
Francia 59590 B2B Servicios
DIN Bellows Seal Stop Valves (Angle Type)

Miércoles 14 septiembre 2016

Cantidad : 5000 - Precio : 100,00 €

Bellows Seal Stop Valves (Angle Type) DIN Angle Type Bellows Sealed Stop Valve DIN Bellows Seal Globe Valve DIN Faltenbalgventil Eckform DIN Válvulas de fuelle(Paso angular.) DIN ventil uzavírací s vlnovcem rohový DIN Standard seteventil med belg (Vinkel modell) DIN Standardında...

ETM Armaturen

  • 59590 - Henri Durre
  • 86 577 67953935