The installation of the HPLC column should be carried out in the following three steps:

a. Unpack the HPLC column and confirm the type, size, date of manufacture, and solvent stored in the column.

b. Unscrew the sealing plug from the joints at both ends of the column and put it back in the box for spare.

c. According to the flow direction indicated on the HPLC column, connect the inlet end of the column to the outlet of the injection valve through the connecting pipe (if the conditions permit, it is recommended to use the guard column in front of the column); the outlet of the column is connected with the detector. The connecting pipe is a stainless steel pipe having an outer diameter of 1.57 mm and an inner diameter of 0.1 to 0.3 mm.

Both ends of the connecting tube have a hollow screw and a sealing ring for sealing. Always try to reduce the dead volume outside the column when taking over. After the connecting tube passes through the hollow screw and the pressure ring, insert it as far as possible into the end, then tighten the hollow screw clockwise until it stops, then use the wrench to continue to screw 1/4-1/2 turn clockwise, remember not to use too much force.

If the HPLC column is leaking after being pressurized by the mobile phase, use a wrench to continue to turn 1/4 turn clockwise until it does not leak.

Ubicación : Xi'an City , Shaanxi Province, P.R.China, 710077 Xi'an,
Persona a contactar : Bruce Lu, +86 29 89284429

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
Installation of the HPLC Column

Buscar en la categoria : Varios / Descuento
Buscar en la categoria :
installation, hplc, column
Francia 529000 Bienes de equipo
2-Wire Flat Cool White LED Rope Light

Sábado 19 julio 2014

Cool White LED with color temperature 7000K to 7500K implies a mild blue tint in the white glow. Cool White is preferred in many applications because the light they output makes items illuminated appear crisper. Cool White is often preferred in bathrooms and other task areas. Note...

Real Green lighting Company

  • Bonny Chan
  • 529000 - Jiangmen City
  • +15 6 02 20 39 93
Francia 59590 B2B Servicios
DIN GLOBE VALVE

Miércoles 14 septiembre 2016

Cantidad : 5000 - Precio : 50,00 €

Gland Packing Globe Valves ( Straight- Through Type) DIN Standard Gland Packing Globe Valve DIN Globe valve DIN Stop valve DIN Absperrventil Durchgangsform DIN Válvulas de globo DIN ventil uzavírací s klasickou ucpávkou přímý DIN Standard seteventiler med pakkboks (rett løp...)

ETM Armaturen

  • 59590 - Henri Durre
  • 86 577 67953935
Francia 59590 B2B Servicios
GATE VALVE

Miércoles 14 septiembre 2016

Cantidad : 5000 - Precio : 50,00 €

Gate Valves (F7 Type) DIN Standard F7 Gate valves / (Length acc.to DIN EN 558-1,face to face series 26 ) DIN F7 Gate valve DIN Absperrschieber F7 DIN Válvulas de compuerta F7 DIN F7 šoupátko stavební délka dle DIN EN558-1 serie 26 DIN Standard F7 sluseventil (lengde iht. DIN EN 558-1...)

ETM Armaturen

  • 59590 - Henri Durre
  • 86 577 67953935