Intrinsic Isolated Barrier
Cantidad : 1 million Precio : 200-2000 CNY/pc
Intrinsic safety barriers and isolators use intrinsically safe explosion-proof and functional safety technologies and adopts various measures such as rapid cut-off, isolation, and energy limiting to ensure that the energy transmitted to the field equipment in the hazardous area is intrinsically safe, thereby preventing dangerous energy from entering the danger zone and causing an explosion.
An isolation barrier, such as the digital input barrier, is a key interface unit in the intrinsically safe explosion-proof control system. The intrinsically safe barrier or the intrinsic safety barrier with quite affordable price made by CHENZHU, one of the top intrinsic safety barrier manufacturers in China, is made under a strict production process and tested by a series of quality assurance systems.
IS Barrier Types
GS8500-EX Series Intrinsic Safety Barrier
GS8500-EX Analogue Intrinsic Safety Barrier
GS8500-EX Analogue Intrinsic Safety Barrier Loop Power
GS8500-EX Digital Intrinsic Safety Barrier
GS8500-EX Digital Intrinsic Safety Barrier Loop Power
GS8500-EX Temperature Converter Intrinsic Safety Barrier
GS8500-EX Voltage Input Intrinsic Safety Barrier
GS8500-EX Communication Input Intrinsic Safety Barrier
GS8500-EX Frequency Converter Intrinsic Safety Barrier
GS5000-EX Series Intrinsic Safety Barrier
GS5000-EX Analogue Intrinsic Safety Barrier
GS5000-EX Analogue Intrinsic Safety Barrier Loop Power
GS5000-EX Digital Intrinsic Safety Barrier
GS5000-EX Digital Intrinsic Safety Barrier Loop Power
GS5000-EX Temperature Converter Intrinsic Safety Barrier
GS8200-EX Series Intrinsic Safety Barrier
GS8200-EX Analogue To RS485 Intrinsic Safety Barrier
LBGS8000-EX Series Surge Protective Intrinsic Safety Barrier
GS4000-EX Series Backplane Intrinsic Safety Barrier
What is Difference Between Intrinsic Isolated Barrier and Intrinsically Safe Isolator?
Isolator
The isolator is used to adjust, isolate and transform all kinds of field instrument signals into the normal signals or special signals specified by users which can be accepted by the computer, DCS, PLS, etc. It is also used to isolate control equipment and operational equipment from electronics, like a relay.
Intrinsic isolated barrier
The isolated barriers for hazardous areas in our safety automation system for sale are associated equipments of explosion-proof instruments that will not affect the function of the measurement system in a normal situation. The isolation barrier is placed on one side of the security site, when the explosion-proof system fails, the intrinsic barrier can limit the energy (electric energy) which can enter the dangerous site to safe values to ensure the safety of the scene.
Difference
1. Different feature. Barrier: High reliability and precision, strong EMC performance. Isolator: Gives electrical isolation among the input & output circuits.
2. Different function. Barrier: Protect electrical signals in potentially flammable or other hazardous areas. Isolator: Adjust, isolate and transform all kinds of field instrument signals into the normal signals or special signals specified by users.
3. Main difference: Explosion proof or not.
What is Safety Level of Intrinsically Safe Electrical Equipment?
IA
IA means that the explosive gas mixture cannot be ignited under normal operation, one counting failure, and two counting failures. IA-level intrinsically safe electrical equipment can be used in hazardous locations in Zone 0, Zone 1, and Zone 2.
IB
IB means that explosive gas mixtures cannot be ignited under normal operation and a counting failure. IB's intrinsically safe electrical equipment that can be used in hazardous locations in Zone 1 and Zone 2.
IC
IC means that explosive gas mixtures cannot be ignited under normal operation. IC-level intrinsically safe electrical equipment can be used in zone 2 hazardous locations.
Persona a contactar : Danping Li, 021 6451 3350
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de Intrinsic Isolated Barrier Buscar en la categoria : Informática Buscar en la categoria : intrinsic, isolated, barrier |
Sábado 19 julio 2014
Our Multi-Color LED Rope Light consist of red, green, blue and yellow LED lights, joining together to form a colorful and breathtaking rope light. Our manufacturer utilizes sophisticated electro-optical designs to control the blend and diffusion of the light. This technology allows...
Real Green lighting Company
- Bonny Chan
- 529000 - Jiangmen City
- +15 6 02 20 39 93
Jueves 28 septiembre 2017
Cantidad : as per ite - Precio : based on Qty
Dear Sir, We deal with Building Materials & Machine Spares since 1987 and LED Lighting and Solar Products since 2014. Our Product Range : Structural Steel : MS Angles, Channel, Beams, Flat Bar, Plain sheets, Chequered plates,Round Bars. Aluminum: plain sheets, Angles, Flat Bars...
Rashid Essa Building Material Co. LLC
- sajj
- 971 - dubai
- 04 2563282
- 971 55 6995965
Domingo 08 julio 2012
Cantidad : 1 - Precio : negotiated
Mobile diving complex executed in double 20 ft marine containers with 60 m diver depth and diving station for operation of 2 working and 1 standing by divers. 1st container Diving complex: 20' marine container with additional door, illuminators and heat insulation, main switchboard...
MSCO
- 183038 - Murmansk
- +78 1 52 48 10 21
- +79 2 16 66 33 86
![Pago seguro](https://es.algomtl.com/images/side_paiement.jpg)