MemoPart Atrial Septal Defect (ASD) Occluder
MemoPart™
Accurate occluding, stable clamping
MemoPart™ Atrial Septal Defect (ASD) Occluder Details
ASD occluder device Description
MemoPart™ ASD Occluder is a self-expanding double-disc nitinol mesh occlusion device. The 2 discs are connected by a short waist that relates to the defect size. Polyester fabric is securely sewn to each disc to increase occlusion. The device is visible under X-ray.
ASD occluder device Features
Modified rigidity and flexibility for different type of occluders - greater stiffness of Atrial Septal Defect Occluder (ASDO) offers excellent supporting force for big disks.
Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.
The hubless design of Atrial Septal Defect Occluder (ASDO) helps with earlier endothelialization to minimize the risk of thrombosis.
Indications for Use ASD Occlusion Device
The MemoPart™ ASD Occluder is a percutaneous, transcatheter, atrial septal defect closure device intended for the occlusion of atrial septal defects (ASD)in secundum position or patients who have undergone a fenestrated Fontan procedure and who require closure of the fenestration.
Patients indicated for ASD closure have echocardiographic evidence of ostium secundum atrial septal defect and clinical evidence of right ventricular volume overload(i.e.,1.5: 1 degree of left-to-right shunt or RV enlargement ).
Ordering Information
Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
Device |
A |
B LA Disc Diameter (mm) |
C |
H |
|
FQFDQ- Ⅰ 06 |
6 |
6 |
16 |
14 |
3 |
|
FQFDQ- Ⅰ 07 |
7 |
7 |
21 |
17 |
3 |
|
FQFDQ- Ⅰ 08 |
8 |
8 |
18 |
16 |
3 |
|
FQFDQ- Ⅰ 09 |
9 |
9 |
23 |
19 |
3 |
|
FQFDQ- Ⅰ 10 |
10 |
10 |
20 |
18 |
3 |
|
FQFDQ- Ⅰ 11 |
11 |
11 |
25 |
21 |
3 |
|
FQFDQ- Ⅰ 12 |
12 |
12 |
22 |
20 |
3 |
|
FQFDQ- Ⅰ 13 |
13 |
13 |
27 |
23 |
3 |
|
FQFDQ- Ⅰ 14 |
14 |
14 |
24 |
22 |
3 |
|
FQFDQ- Ⅰ 15 |
15 |
15 |
29 |
25 |
4 |
|
FQFDQ- Ⅰ 16 |
16 |
16 |
30 |
26 |
4 |
|
FQFDQ- Ⅰ 17 |
17 |
17 |
31 |
27 |
4 |
|
FQFDQ- Ⅰ 18 |
18 |
18 |
32 |
28 |
4 |
|
FQFDQ- Ⅰ 19 |
19 |
19 |
33 |
29 |
4 |
|
FQFDQ- Ⅰ 20 |
20 |
20 |
34 |
30 |
4 |
|
FQFDQ- Ⅰ 22 |
22 |
22 |
36 |
32 |
4 |
|
FQFDQ- Ⅰ 24 |
24 |
24 |
38 |
34 |
4 |
|
FQFDQ- Ⅰ 26 |
26 |
26 |
40 |
36 |
4 |
|
FQFDQ- Ⅰ 28 |
28 |
28 |
42 |
38 |
4 |
|
FQFDQ- Ⅰ 30 |
30 |
30 |
44 |
40 |
4 |
|
FQFDQ- Ⅰ 32 |
32 |
32 |
47 |
42 |
4 |
|
FQFDQ- Ⅰ 34 |
34 |
34 |
49 |
44 |
4 |
|
FQFDQ- Ⅰ 36 |
36 |
36 |
51 |
46 |
4 |
|
FQFDQ- Ⅰ 38 |
38 |
38 |
54 |
50 |
4.5 |
|
FQFDQ- Ⅰ 40 |
40 |
40 |
56 |
52 |
4.5 |
|
FQFDQ- Ⅰ 42 |
42 |
42 |
58 |
54 |
4.5 |
|
FQFDQ- Ⅰ 44 |
44 |
44 |
60 |
56 |
4.5 |
|
FQFDQ- Ⅰ 46 |
46 |
46 |
62 |
58 |
4.5 |
|
FQFDQ- Ⅰ 48 |
48 |
48 |
64 |
60 |
4.5 |
|
FQFDQ- Ⅰ 50 |
50 |
50 |
66 |
62 |
4.5 |
Hubless Atrial Septal Defect (ASD) Occluder
|
Catalogue No. Device |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
WTFQFDQ- Ⅰ 06 |
06 |
6 |
16 |
14 |
3 |
|
WTFQFDQ- Ⅰ 07 |
07 |
7 |
21 |
17 |
3 |
|
WTFQFDQ- Ⅰ 08 |
08 |
8 |
18 |
16 |
3 |
|
WTFQFDQ- Ⅰ 09 |
09 |
9 |
23 |
19 |
3 |
|
WTFQFDQ- Ⅰ 10 |
10 |
10 |
20 |
18 |
3 |
|
WTFQFDQ- Ⅰ 11 |
11 |
11 |
25 |
21 |
3 |
|
WTFQFDQ- Ⅰ 12 |
12 |
12 |
22 |
20 |
3 |
|
WTFQFDQ- Ⅰ 13 |
13 |
13 |
27 |
23 |
3 |
|
WTFQFDQ- Ⅰ 14 |
14 |
14 |
24 |
22 |
3 |
|
WTFQFDQ- Ⅰ 15 |
15 |
15 |
29 |
25 |
4 |
|
WTFQFDQ- Ⅰ 16 |
16 |
16 |
30 |
26 |
4 |
|
WTFQFDQ- Ⅰ 17 |
17 |
17 |
31 |
27 |
4 |
|
WTFQFDQ- Ⅰ 18 |
18 |
18 |
32 |
28 |
4 |
|
WTFQFDQ- Ⅰ 19 |
19 |
19 |
33 |
29 |
4 |
|
<span style="font-family |
Persona a contactar : medical lepu, 86 10 80120666
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
|
Esta página es acerca de los importadores y exportadores de MemoPart™ Atrial Septal Defect (ASD) Occluder Buscar en la categoria : Medicina Buscar en la categoria : septal, memopart™, occluder, atrial, defect |
Tuesday 23 February 2016
This pressure transmitter ( High Quality Smart Differential Pressure Transmitters ) using imported pressure sensor, temperature compensation of laser resistor trimming by using compute r, integrated wiring box design. With special terminal and digital display, installation, calibratio...
Dalian Teren Instruments Co,Ltd
- 116031 - DALIAN
- 86 18642631917
Wednesday 04 November 2015
Cantidad : 100 - Precio : 10-50USD
ISO/TS16949 Manufacturer Ductile Iron Casting Foundry Specification Ductile iron casting's specification according to custom drawing. Please kinldy provide us your drawing. Description Iron / Steel Castings: 1) Process: Resin sand/Green Sand/Investment Casting 2) Specification: 1...
Shanxi Qinghui Mechanical Manufacture Co., Ltd.
- 048000 - Jincheng
- (+86) 356 3875978
Tuesday 07 July 2015
YMRF-70H ~100H Laser Marking Machine YMRF 70H-100H series laser marking machine is able to extend marking area in a single direction. Equipped with 100W radio-frequency laser imported from USA and and high speed scan mirror system ,The machine can achieve strong power of laser ,incomparable...
GD Han's YueMing Laser Technology Co., Ltd
- 523000 - Dongguan
- +86 769 22705851/89838888