MemoPart Patent Ductus Arteriosus (PDA) Occluder
MemoPart™
Multiple designs, anastomosing lesions
MemoPart™ Patent Ductus Arteriosus (PDA) Occluder Details
Product Description
MemoPart™ PDA Occluder is a self-expandable device made from nitinol wire mesh. Aretention skirt on the aortic side provides secure positioning in the ampulla of the ductus. As the occluder is implanted, it expands outward and the wires push against the wall of the ductus. Polyester fabric is sewn into the occluder with polyester thread.The fabric induces thrombosis that closes the communication.
Product Features
Modified rigidity and flexibility for different type of occluders - balanced stiffness of Patent Ductus Arteriosus Occluder (PDAO) ensures the optimal occlusion performance.
Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.
The hubless design of Patent Ductus Arteriosus Occluder (PDAO) helps with earlier endothelialization to minimize the risk of thrombosis.
Indications for Use
The MemoPart™ Patent Ductus Arteriosus (PDA) Occluder can be used for the nonsurgical closure of apatent ductus arteriosus (PDA) in the percutaneous, transcatheter therapy.
Ordering Information
Cone Shape PDA Occluder Device
Catalogue No. |
Device |
B |
C |
A |
H |
WBFDQ- Ⅱ 06 |
406 |
6 |
4 |
10 |
6 |
WBFDQ- Ⅱ 08 |
608 |
8 |
6 |
12 |
6.5 |
WBFDQ- Ⅱ 10 |
810 |
10 |
8 |
14 |
7.5 |
WBFDQ- Ⅱ 12 |
1012 |
12 |
10 |
16 |
8.5 |
WBFDQ- Ⅱ 14 |
1214 |
14 |
12 |
18 |
9.5 |
WBFDQ- Ⅱ 16 |
1416 |
16 |
14 |
20 |
10.5 |
WBFDQ- Ⅱ 18 |
1618 |
18 |
16 |
23 |
10.5 |
WBFDQ- Ⅱ 20 |
1820 |
20 |
18 |
25 |
12 |
WBFDQ- Ⅱ 22 |
2022 |
22 |
20 |
27 |
12 |
Hubless Cone Shape Patent Ductus Arteriosus (PDA) Occluder
Catalogue No. |
Device |
B |
C |
A |
H |
WTWBFDQ- Ⅱ 06 |
406 |
6 |
4 |
10 |
6 |
WTWBFDQ- Ⅱ 08 |
608 |
8 |
6 |
12 |
6.5 |
WTWBFDQ- Ⅱ 10 |
810 |
10 |
8 |
14 |
7.5 |
WTWBFDQ- Ⅱ 12 |
1012 |
12 |
10 |
16 |
8.5 |
WTWBFDQ- Ⅱ 14 |
1214 |
14 |
12 |
18 |
9.5 |
WTWBFDQ- Ⅱ 16 |
1416 |
16 |
14 |
20 |
10.5 |
WTWBFDQ- Ⅱ 18 |
1618 |
18 |
16 |
23 |
10.5 |
WTWBFDQ- Ⅱ 20 |
1820 |
20 |
18 |
25 |
12 |
WTWBFDQ- Ⅱ 22 |
2022 |
22 |
20 |
27 |
12 |
Cylinder Shape Patent Ductus Arteriosus (PDA) Occluder
Catalogue No. |
Device |
B |
C |
A |
H |
WBFDQ- Ⅰ 04 |
4 |
4 |
4 |
8 |
4.0 |
WBFDQ- Ⅰ 05 |
5 |
5 |
5 |
9 |
5.0 |
WBFDQ- Ⅰ 06 |
6 |
6 |
6 |
10 |
6.0 |
WBFDQ- Ⅰ 07 |
7 |
7 |
7 |
11 |
6.5 |
WBFDQ- Ⅰ 08 |
8 |
8 |
8 |
12 |
6.5 |
WBFDQ- Ⅰ 09 |
9 |
9 |
9 |
13 |
7 |
WBFDQ- Ⅰ 10 |
10 |
10 |
10 |
14 |
7.5 |
WBFDQ- Ⅰ 11 |
11 |
11 |
11 |
15 |
8 |
WBFDQ- Ⅰ 12 |
12 |
12 |
12 |
16 |
8.5 |
WBFDQ- Ⅰ 13 |
13 |
13 |
13 |
17 |
8.5 |
WBFDQ- Ⅰ 14 |
14 |
14 |
14 |
18 |
9.5 |
WBFDQ- Ⅰ 16 |
16 |
16 |
16 |
21 |
10.5 |
WBFDQ- Ⅰ 18 |
18 |
18 |
18 |
23 |
10.5 |
WBFDQ- Ⅰ 20 |
20 |
20 |
20 |
25 |
12 |
WBFDQ- Ⅰ 22 |
22 |
22 |
22 |
27 |
12 |
Hubless Cylinder Shape Patent Ductus Arteriosus (PDA) Occluder
Catalogue No. |
Device |
B |
C |
A |
H |
WTWBFDQ- Ⅰ 04 |
4 |
4 |
4 |
8 |
4 |
WTWBFDQ- Ⅰ 05 |
5 |
5 |
5 |
9 |
5 |
WTWBFDQ- Ⅰ 06 |
6 |
6 |
6 |
10 |
6 |
WTWBFDQ- Ⅰ 07 |
7 |
7 |
7 |
11 |
6.5 |
WTWBFDQ- Ⅰ 08 |
8 |
8 |
8 |
12 |
6.5 |
WTWBFDQ- Ⅰ 09 |
9 |
9 |
9 |
13 |
7 |
WTWBFDQ- Ⅰ 10 |
Persona a contactar : medical lepu, 86 10 80120666
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de MemoPart™ Patent Ductus Arteriosus (PDA) Occluder Buscar en la categoria : Medicina Buscar en la categoria : ductus, occluder, patent, arteriosus, memopart™ |
Jueves 06 noviembre 2014
Cantidad : 5 - Precio : 33,00 €
Retrouver cet article sur : WWW.TEXMARK.FR - Destockeur/Fournisseur de la marque DIESEL en lot. - Tarifs sur simple inscription sur Texmark.fr, site de vente en ligne. - Détails : Lot Jeans Diesel "FAYZA 0808N" - - - - Composition:76% Cotton - 22% Polyester - 2% Elathanne...
SARL TEXMARK
- TEXMARK.FR
- 57500 - SAINT AVOLD
- 06 99 20 84 85
Viernes 13 noviembre 2015
Jawo Sheng Precise Machinery Works Co., Ltd. Founded in 1978, JS have manufactured embossing machine, varnishing machine, flexo printing machine, flexographic printing machine and packaging printing machine over years. Therefore, we have been at the forefront of the industry for...
Jawo Sheng Precise Machinery Works Co., Ltd.
- Sj1978
- 414 - Taichung
- +886 4 2335 8268
- +886423358268
Jueves 03 diciembre 2015
Cantidad : 300 Set/Se - Precio : 1USD
- Quick Details - - Place of Origin: Guangdong, China (Mainland) - Brand Name: EHO - Model Number: GS6.5B - Type: other - Feature: body compostion test - Operation System: body fat analyzer weight - Printer Interfaces: USB - Operation Language: English and multiple...
Guangzhou Yihao Electronic Technology Co., Ltd.
- 510385 - Guangdong
- 86 20 81495407