China Medicina
Medicina

MemoPart Patent Ductus Arteriosus (PDA) Occluder

MemoPart

Multiple designs, anastomosing lesions

MemoPartPatent Ductus Arteriosus (PDA) Occluder Details

Product Description

MemoPartPDA Occluder is a self-expandable device made from nitinol wire mesh. Aretention skirt on the aortic side provides secure positioning in the ampulla of the ductus. As the occluder is implanted, it expands outward and the wires push against the wall of the ductus. Polyester fabric is sewn into the occluder with polyester thread.The fabric induces thrombosis that closes the communication.

Product Features

Modified rigidity and flexibility for different type of occluders - balanced stiffness of Patent Ductus Arteriosus Occluder (PDAO) ensures the optimal occlusion performance.

Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.

The hubless design of Patent Ductus Arteriosus Occluder (PDAO) helps with earlier endothelialization to minimize the risk of thrombosis.

Indications for Use

The MemoPartPatent Ductus Arteriosus (PDA) Occluder can be used for the nonsurgical closure of apatent ductus arteriosus (PDA) in the percutaneous, transcatheter therapy.

Ordering Information

Cone Shape PDA Occluder Device

Catalogue No.

Device
Size

B
Aortic Waist Diameter (mm)

C
Pulmonic Waist Diameter
(mm)

A
Aortic Disc Diameter (mm)

H
Waist Length (mm)

WBFDQ- Ⅱ 06

406

6

4

10

6

WBFDQ- Ⅱ 08

608

8

6

12

6.5

WBFDQ- Ⅱ 10

810

10

8

14

7.5

WBFDQ- Ⅱ 12

1012

12

10

16

8.5

WBFDQ- Ⅱ 14

1214

14

12

18

9.5

WBFDQ- Ⅱ 16

1416

16

14

20

10.5

WBFDQ- Ⅱ 18

1618

18

16

23

10.5

WBFDQ- Ⅱ 20

1820

20

18

25

12

WBFDQ- Ⅱ 22

2022

22

20

27

12

Hubless Cone Shape Patent Ductus Arteriosus (PDA) Occluder

Catalogue No.

Device
Size

B
Aortic Waist Diameter (mm)

C
Pulmonic Waist Diameter
(mm)

A
Aortic Disc Diameter (mm)

H
Waist Length (mm)

WTWBFDQ- Ⅱ 06

406

6

4

10

6

WTWBFDQ- Ⅱ 08

608

8

6

12

6.5

WTWBFDQ- Ⅱ 10

810

10

8

14

7.5

WTWBFDQ- Ⅱ 12

1012

12

10

16

8.5

WTWBFDQ- Ⅱ 14

1214

14

12

18

9.5

WTWBFDQ- Ⅱ 16

1416

16

14

20

10.5

WTWBFDQ- Ⅱ 18

1618

18

16

23

10.5

WTWBFDQ- Ⅱ 20

1820

20

18

25

12

WTWBFDQ- Ⅱ 22

2022

22

20

27

12

Cylinder Shape Patent Ductus Arteriosus (PDA) Occluder

Catalogue No.

Device
Size

B
Aortic Waist Diameter (mm)

C
Pulmonic Waist Diameter
(mm)

A
Aortic Disc Diameter (mm)

H
Waist Length (mm)

WBFDQ- Ⅰ 04

4

4

4

8

4.0

WBFDQ- Ⅰ 05

5

5

5

9

5.0

WBFDQ- Ⅰ 06

6

6

6

10

6.0

WBFDQ- Ⅰ 07

7

7

7

11

6.5

WBFDQ- Ⅰ 08

8

8

8

12

6.5

WBFDQ- Ⅰ 09

9

9

9

13

7

WBFDQ- Ⅰ 10

10

10

10

14

7.5

WBFDQ- Ⅰ 11

11

11

11

15

8

WBFDQ- Ⅰ 12

12

12

12

16

8.5

WBFDQ- Ⅰ 13

13

13

13

17

8.5

WBFDQ- Ⅰ 14

14

14

14

18

9.5

WBFDQ- Ⅰ 16

16

16

16

21

10.5

WBFDQ- Ⅰ 18

18

18

18

23

10.5

WBFDQ- Ⅰ 20

20

20

20

25

12

WBFDQ- Ⅰ 22

22

22

22

27

12

Hubless Cylinder Shape Patent Ductus Arteriosus (PDA) Occluder

Catalogue No.

Device
Size

B
Aortic Waist Diameter (mm)

C
Pulmonic Waist Diameter
(mm)

A
Aortic Disc Diameter (mm)

H
Waist Length (mm)

WTWBFDQ- Ⅰ 04

4

4

4

8

4

WTWBFDQ- Ⅰ 05

5

5

5

9

5

WTWBFDQ- Ⅰ 06

6

6

6

10

6

WTWBFDQ- Ⅰ 07

7

7

7

11

6.5

WTWBFDQ- Ⅰ 08

8

8

8

12

6.5

WTWBFDQ- Ⅰ 09

9

9

9

13

7

WTWBFDQ- Ⅰ 10

Ubicación : No.37 Chaoqian Road Changping District, Beijing, China, 102200 Beijing,
Persona a contactar : medical lepu, 86 10 80120666

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
MemoPart™ Patent Ductus Arteriosus (PDA) Occluder

Buscar en la categoria : Medicina
Buscar en la categoria :
patent, memopart™, occluder, ductus, arteriosus
Francia 57500 Ropa mujer
Soldeur destockeur Jeans Diesel Femme

Thursday 06 November 2014

Cantidad : 5 - Precio : 33,00 €

Retrouver cet article sur : WWW.TEXMARK.FR - Destockeur/Fournisseur de la marque DIESEL en lot. - Tarifs sur simple inscription sur Texmark.fr, site de vente en ligne. - Détails : Lot Jeans Diesel "FAYZA 0808N" - - - - Composition:76% Cotton - 22% Polyester - 2% Elathanne...

SARL TEXMARK

China 510385 Higiene / salud
Pressotherapy products IHAP118G touch screen lymphatic drainage massage beauty system

Thursday 26 November 2015

Cantidad : 200 Set/S - Precio : 1USD

- Quick Details - - Place of Origin: Guangdong, China (Mainland) - Brand Name: EHO - Model Number: IHAP118G - Type: Pressotherapy products - Feature: Cellulite Reduction, Detox,weight loss,pressotherapy system - Operation System: air pressure;Pressotherapy - Output Voltage...

Guangzhou Yihao Electronic Technology Co., Ltd.

  • 510385 - Guangdong
  • 86 20 81495407
China 518000 Varios / Descuento
A200 temporary dog yard fencing ,dog fence outdoor

Saturday 05 July 2014

Cantidad : 1set - Precio : 29.2usd

A200 temporary dog yard fencing ,dog fence outdoor <img src="http://i01.i.aliimg.com/img/pb/660/395/631/631395660_367.jpg" alt="A200 temporary dog yard fencing ,dog fence outdoor" width="560" height="451" style="margin: 0px; padding: 0px; font-size:0px; font-style: inherit; line-height...

Shenzhen Jianfeng Electronic Pet Product Co., Ltd

  • 518000 - shenzhen
  • +0086 18507920694
  • +18 5 07 92 06 94