Oxygen Index Tester
Introduction
To automatically determine the minimum quantity of oxygen required for combustion. The apparatus determines the flammability characteristics of the materials used in the production of electric cables. The oxygen percentage is detected by a paramagnetic transducer (O2 accuracy <0.1%), and the combustion occurs inside the glass column. The operator is fixing only the O<sup>2 ratio, while the N2 flux is kept constant by proportional valve of the electronic system. Two units separated, one to check the measurements and one to feed oxygen and nitrogen to the column where the testing sample is placed.
Technical Parameter:
Main unit:360 x 300 x 240 h (mm)
Colum unit:200 x 300 x 50 h (mm)
Colum:Type A ,Ø100 x 450 h (mm)
Overall dimension:360 x 300 x 740 h (mm)
Net weight:13 kg
Gross weight:19kg
Power supply:230 V 50Hz,single phase
Gas:oxygen, nitrogen, propane, dry industrial air 2 bar
Standards
ASTM D 2863 Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index)
ISO 4589-2 Plastics-Determination of burning behaviour by oxygen index –Part 2: Ambient-temperature test
CEI 20-22/4 Tests on electric cables under fire conditions-Part 3: Tests on bunched wires or cables
Configuration include:
Support for self supporting specimens
Support for non-self supporting specimens
Support for thin specimens
Column Pyrex glass with cap
Burner for the ignition of the sample with manual regulator and gas hose
Clamp for specimen positioning
Determination of the percentage of oxygen through a paramagnetic transducer (accuracy O2 <0.1% )<br />
Direct reading on color display 3.2" (% Oxygen, Flow, Air)
Automatic flow through Mass flow
Automatic mixing oxygen / nitrogen
Management of equipment Microprocessor
Management mixture by addition of air to more economic measures with high concentration oxygen
Automatic calibration (0 and 100%)
Distributor flow inside the column
USB output to connecting PC
Optional: Software testing report data, easy to use, customize your testing procedures and final report.
Qinsun-lab also provides the following different types of oxygen index testers:
1. High Temperature Oxygen Index Tester
2. Rubber/Asphalt Oxygen Index Tester:
Persona a contactar : Sun Qin, +86 21 6780 0179
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de Oxygen Index Tester Buscar en la categoria : Bienes de equipo Buscar en la categoria : oxygen, index, tester |
Miércoles 14 septiembre 2016
Cantidad : 5000 - Precio : 50,00 €
Long life-Heavy Duty Bellows Seal Stop Valves DIN Standard Long Life-Heavy Duty Bellows Sealed Stop Valves DIN Long life bellows Seal Stop Valve DIN Long life bellows globe valve DIN Long bonnet bellows globe valve DIN Faltenbalgventil lange Bauform DIN Válvulas de fuelle de...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Miércoles 14 septiembre 2016
Cantidad : 5000 - Precio : 50,00 €
Gland Packing Globe Valves ( Straight- Through Type) DIN Standard Gland Packing Globe Valve DIN Globe valve DIN Stop valve DIN Absperrventil Durchgangsform DIN Válvulas de globo DIN ventil uzavírací s klasickou ucpávkou přímý DIN Standard seteventiler med pakkboks (rett løp...)
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935
Miércoles 14 septiembre 2016
Cantidad : 5000 - Precio : 100,00 €
Bellows Seal Stop Valves (Angle Type) DIN Angle Type Bellows Sealed Stop Valve DIN Bellows Seal Globe Valve DIN Faltenbalgventil Eckform DIN Válvulas de fuelle(Paso angular.) DIN ventil uzavírací s vlnovcem rohový DIN Standard seteventil med belg (Vinkel modell) DIN Standardında...
ETM Armaturen
- 59590 - Henri Durre
- 86 577 67953935