PN3000-HFNC High Flow Nasal Cannula
Cantidad : 5000 units Precio : USD 15--USD 2200
Pigeon heated high flow cannula(HFNC) oxygen therapy is a form of non –invasive respiratory support,which comprises an air oxygen blender mixer, respiratory humidifier, a single heated circuit and a heated nasal cannula.It delivers adequately heated and humidified medical gas up to 60L/min,and is considered to have a number of physiological effects.
Working Principle of PN3000-HFNC High Flow Nasal Cannula
Pigeon adult HFNC pigeon adopts a soft, comfortable, lightweight breathing circuit and a unsealed high-flow nasal oxygen cannula to deliver a mixed high-flow gas to patient. Since the mask is not required, the patient can eat and talk without being affected while receiving treatment. After finishing machine connection, gas and oxygen come into blender and be adjusted to certain concentration, inpired gas goes through humidifier and is heated to be with certain temperature and humidity, the machine has automatic temperature detection function, which makes patients' breath smoothly and comfortably.
Features of PN3000-HFNC High Flow Nasal CPAP Cannula
Automatical temperature detection
Stable performance
Mechanical type blender design.
Medical air compressor can be optional in the case of absence or failure of central air supply.
Specification of PN3000-HFNC Nasal Cannula Max Flow
|
Adjustment of Oxygen Concentration |
Mechanical |
||
|
FiO2 |
21%-100% |
||
|
Flow |
6-60LPM |
||
|
Pressure of gas source |
Air/Oxygen@0.3-0.4 Mpa |
||
|
Blender Alarm |
When gas supply pressure difference > 0.1 Mpa |
||
|
Blender Alarm Noise |
>57 dB(A) |
||
|
Accuracy of FiO2 |
0.03 |
||
|
Humidifier Supply Voltage/Frequency |
220V/ 110V 50/60Hz |
||
|
Humidifier Temperature monitoring |
0-75℃ |
||
|
Humidifier Heater Plate Over-temperature Cut Off |
95±5℃ |
||
|
Heater Wire(Max.) |
22V-,2.73A, 60W, 50/60Hz |
||
|
Humidifier Temperature control settings |
Heated wire mode(mode indicator lighted) |
||
|
Temperature grade(with indicator status) |
Continuous flow range |
Delivered patient temperature |
|
|
P1 (●○○) |
5L/min-60L/min |
25-29℃ |
|
|
P2 (●●○) |
5L/min-60L/min |
29-35℃ |
|
|
P3 (●●●) |
5L/min-60L/min |
35-39℃ |
|
|
Non-heated wire mode(It is not recommended in adult HFNC. Operate manual of humidifier show details) |
|||
Pigeon Medical specializes in manufacturing respiratory therapy equipment & high flow oxygen therapy devices. Main products are air-oxygen blender, medical air compressor, respiratory humidifier and high-flow nasal cannula. We also have considerable experience in providing solutions for non-invasive, invasive ventilation and high flow nasal therapy.
Persona a contactar : Zhou Alex , +18 8 98 65 17 88
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
|
Esta página es acerca de los importadores y exportadores de PN3000-HFNC High Flow Nasal Cannula Buscar en la categoria : B2B Servicios Buscar en la categoria : cannula, flow, high, nasal, pn3000, hfnc |
Thursday 10 April 2014
Cantidad : 1000
Spécifications du produit / Modèles Code de l'article: C500, C650, C750, C1000 Couleur: Transparent Capacité: 500ml, 650ml, 750ml, 1000ml application Adapté pour l'utilisation dans les emballages alimentaires, plats à emporter, à l'aide de micro-ondes. Autres informations haute...
QUI PHUC TRADING-SERVICE-PRODUCTION CO.,LTD
- quiphuc
- 84 - HCM city
- +84 (0)8 54263229
- +84 9 74 00 02 86
Saturday 02 August 2014
Cantidad : 300pcs - Precio : 10-50USD/PC
Ingrédients: talc, mica, huile minérale, kaolin, dioxyde de titane, stéarate de magnésium, le palmitate d'isopropyle, la lanoline, parahydroxybenzoate de méthyle, parahydroxybenzoate de propyle, BHT. Peut contenir: Mica et le dioxyde de titane, Des oxydes de fer, bleu outremer, l'oxyde Verts...
ShenzhenMakefayCosmeticsCo.,Ltd
- 518000 - Shenzhen
- 0755 89391213
Tuesday 23 December 2025
Cantidad : 80000 Ream - Precio : $0.79/Ream for 8000
ESPECIFICACIONES - Tamaño de hoja: 210mm x 297mm / 297mm x 420mm Normas Internacionales de papel Tamaño (ISO) A4 / A3 - Calidad: Importado 100% pulpa de madera virgen - Blancura: 102-104%, blanco natural - Clasificación: A - Espesor: 106cm - Capacidad: High Speed Copiado 100 ppm...
NATH LAOH LTD
- 50100 - Chiang Mai
- +66 9 95 35 59 56