Varios / Descuento

Reason Analysis of Using AOC Active Optical Cable in Data Center Wiring

40G/100G AOC active optical cable has been globally introduced throughout the aoc data center field. Compared to 40G DAC copper cable, 40G AOC active optical cable has unparalleled advantages in data transmission environment above 7 meters, including the smaller size, lighter weight, easier bending, easier management, longer signal transmission distance, etc. In the data center, the same goals can be achieved with a 40G SR4 optical transceiver. The differences between 40G AOC active optical cable and SR4 optical transceiver are analyzed as follows:

1. Insertion loss analysis of 40G AOC active optical cable and SR4 optical transceiver

With the same transmission distance, for SR4 optical transceiver, different optical fiber jumpers that are connected to the same module will produce different insertion loss and return loss, which is basically a common problem. However, as long as the variation is within the range, there will be no significant change in the eye map and other related indexes.

The AOC active optical cable which is well made is basically stable and has better rocking performance. The repeated test of the SR4 optical transceiver produced a large fluctuation.

2. Four-quadrant test of 40G AOC active optical cable and SR4 optical transceiver

It is measured at four combinations of input voltage and signal amplitude to ensure that the performance can be maintained at both the lowest and highest voltages and temperatures. AOC active optical cable is required to pass quadrant tests with a wide temperature range to ensure that the MPO interface and cable of AOC will not melt at high temperatures. The performance change of MPO interface itself at high and low temperatures can meet the change of 0.3 dB, and the materials used are PEI materials that can resist the temperature of above 120 degrees.

As an all-in-one product, the all-in-one test ensures the performance of the product, which may be more stable than SR4 optical transceiver that adopts MPO jumper with uncertain performance. Compared with SR4 optical transceiver that confirms the quality through optical eye diagram, AOC active optical cable mainly uses the eye diagram to judge the quality of indicators.

3. DDM monitoring of 40G AOC active optical cable and SR4 optical transceiver

QSFP+ SR4 optical transceiver has the DDM monitoring function. When receiving coupling, the ADC value of the receiver can be monitored in real time to determine the optimal coupling. Therefore, SR4 is more superior than AOC in terms of receiving sensitivity.

4. Transmission distance of 40G AOC active optical cable and SR4 optical transceiver

There is not much difference in the OM3 fibers, but the 40G QSFP+ SR4 optical transceiver provides better performance control. QSFP+SR4 is recommended if you want to achieve a longer distance (> 300 m) transmission.

Active fiber optical cable (AOC) is recommended based on the data connection in the data center, because it provides better wiring consistency and repeatability, and the closed ends are easier to avoid the effects of environmental and vibration oscillations. If there is a failure, it can be replaced directly without the need to carry out a series of end-to-plug tests of 40G QSFP+SR4 optical transceiver and MPO jumper on site, which is more beneficial to save costs.

There are many fiber optic accessories suppliers, but we are one of the best choices for you.

Ubicación : 8 Jinxiu Middle Road, Pingshan, Shenzhen, Guangdong, China, 518118 Jinxiu Middle Road,
Persona a contactar : Lin Jack, 0755 32983688

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
Reason Analysis of Using AOC Active Optical Cable in Data Center Wiring

Buscar en la categoria : Varios / Descuento
Buscar en la categoria :
reason, using, optical, active, cable, analysis, data
Thailandia 10500 Telefonía
Samsung Galaxy Note II Android 4.1

Lunes 04 marzo 2013

Cantidad : 30 - Precio : $425.00

Samsung Galaxy Note II It's a phablet… phone cum tablet. The Note II is an ultimate Smartphone with the latest features and specifications to enthrall any tech savvy person. Specifications: Basic Information Model N7100 2G:GSM 850/900/1800/1900 3G:WCDMA 850/900/1900/2100MHz Sim Card...

Mobiworld

Thailandia 10110 Materias primeras
De alta calidad de alambre de cobre Chatarra 99,99% Milberry

Martes 14 julio 2015

Cantidad : 15000MT - Precio : 2500euro

De alta calidad de alambre de cobre Chatarra 99,99% Milberry somos proveedores de chatarra de cable de cobre especificación Cobre CHATARRA DE ALAMBRE, (Millberry) 99,78% con una pureza de 99,78% min. 99.78% Max. COBRE: 99, 9% CARBONO: 0,03% COBLET: <0, 001</div> HIERRO...

CA PRODUCTS CO, LTD

  • 10110 - bangkok
  • +66 2 62 61 74 11
  • +66 9 62 91 74 69
Taiwán 833 Construcción
Rim Lock Cylinder

Martes 11 agosto 2015

One Lus International is a professional lock cylinder manufacturer in Taiwan and provides a series of lock cylinder to meet customer's needs. The key locking cable is made of brass cylinder and bronze key. If you have interested in our lock cylinder, welcome to browse the lock cylinder...

One Lus International Co., Ltd.