Sidestream EtCO2 Sensors
Sampling Line
A sampling line is a component of medical devices used to collect and transport samples of gases or fluids for analysis or measurement. It is commonly used in various clinical settings, including anesthesia, respiratory therapy, and critical care.
L-Type EtCO2 ConnectorThe "L-shaped connector" is adapted to the "sampling tube" to connect to the air circuit, so that the side-stream EtCO2 sensor can accurately and quickly collect the value of end-tidal carbon dioxide. Single use consumables.
L-Type EtCO2 Connector
How does Sidestream EtCO2 Sensor Work?
Sidestream EtCO2 sensors work by using a sampling tube to draw a small sample of exhaled gas from the patient's airway. This sample is then transported to the sensor for analysis and measurement of carbon dioxide levels. The sampling tube is connected to the patient's airway through an adapter or cannula. A small pump or vacuum within the capnography system helps to draw the gas sample through the tube to the sensor. Once the sample reaches the sensor, it analyzes the carbon dioxide concentration and provides the EtCO2 reading.
Sidestream capnography requires a small amount of gas flow to be diverted from the patient's airway, leading to a slight delay in measurement compared to mainstream capnography.
FAQs of Sidestream EtCO2 Sensors
What is sidestream EtCO2?
Sidestream EtCO2 refers to the measurement of end-tidal carbon dioxide levels by sampling a small portion of exhaled gas through a sampling tube located away from the patient's airway.
What is the flow rate of sidestream capnography?
Typically, the flow rate of sidestream capnography is around 50-200 milliliters per minute (mL/min).
What are the advantages of sidestream capnography?
Non-intrusive and less uncomfortable for patients compared to mainstream capnography.
Provides flexibility in terms of sensor placement and can be used with various airway adapters.
Can be used in a wide range of clinical settings and patient populations.
Offers reliable and accurate measurements of end-tidal carbon dioxide levels.
Allows for continuous monitoring of ventilation and respiratory function.
If you want to know more about sidestream etco2 detection, please visit our website.
Now the price of capnometer for sale is reasonable, anything you need, please contact us.
Persona a contactar : MED CAPNO, 0335 8595611
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
|
Esta página es acerca de los importadores y exportadores de Sidestream EtCO2 Sensors Buscar en la categoria : Materias primeras Buscar en la categoria : etco2, sensors, sidestream |
Saturday 28 November 2015
V Folds welded Wire Mesh Fence : Wire Mesh fencing covers a vast range of mesh fencing products from ligh t agricultural and farm wire mesh / netting to commercial welded mesh fencing and strong and versatile < /span> mesh security fencing. Mesh Fencing is a very popular...
Hebei SECURE NET Fence Facility Co., Ltd
- 053600 - Hebei
- 86 311 68036973
Tuesday 24 September 2013
Cantidad : 1000 - Precio : 1 000,00 €
ASME SA213 T91 , ASTM A213 , ASTM A213 T91 , T91 SA213 , tubos de acero de aleación , tubo de aleación ASTM A213 T91 es la parte de la norma ASTM A213 Especificación estándar para Seamless , sobrecalentador , tubos de intercambiador de calor ferríticos y austeníticos aleación de...
Sunny Steel Tubosacero Ltd.
- tubosacero
- Shanghai - 闸北
- 862133780199
- 862161851035
Wednesday 15 February 2017
Cantidad : 1set - Precio : USD10000-1000000
Usage of this device Steelmaking electric arc furnace inputs electric energy into furnace by graphite electrode. Electric arc producing between electrode tips and furnace burden is used as heat source to smelt steel. The heat source of electric arc furnace is electric energy. Atmosphere...
SHOO-IN (ITL) Holding Xi'an Equipment Co., Ltd
- 710065 - Xian
- 862987306978