Bienes de equipo

Single-core Logging Cable

1. Application

Use for all kinds of gas and oil well operations such as logging, perforation, coring, etc.

2. Characteristic

Logging cable, belonging to electric devices cable, is mainly used for bearing pulling strength, sys tem power supply, signal transmission and depth control.

3. Scope of Production

We can produce according to customers' requirements. At present, we can offer many kinds of logging cables with four temperature ratings of 150 ℃, 180 ℃, 232 ℃, 160 ℃. The diameter ranges from 5.6mm t o 13.2mm.

4. Technical Parameters

W1B—5.6 1*0.56

1) O.D. of Cable: 5.6mm

2) O.D. Inner Armor: 3.8mm

3) Conductor DC Resistance: ≤34 Ω/km 20℃

4) Insulation Resistance: ≥500MΩ/km 20℃

5) Insulation Resistance of High Temperature: 2.5MΩ/km

6) A.C. Voltage Withstand Test: 1000V 50Hz 5min

7) Capacitance: ≤0.16 μ F/km 800-1000Hz

8) Breaking Strength: 24kN

9) Working Tension: <12kN

10) Minimum Sheave Diameter: 330mm

11) Stretch Coefficient: 2.5m/km/5kN

12) Working Temperature for Long-term: 100℃

13) Temperature Range: -30℃ ~ 150℃

14) Weight of Cables: 142kg/km

15) The length of cable delivery is between 3000 meters and 8000 meters( between 9843ft and 26248ft) per reel, allowable deviation is -2%~3%. Any length can be delivered by mutual agreement.

Note: If choose the anti-sulfur cable, the breaking strength will be 85% of the value.

W1F—8.0 1*1.0

1) O.D. of Cable: 8.0mm

2) O.D. Inner Armor: 5.7mm

3) Conductor DC Resistance: ≤17 Ω/km 20℃

4) Insulation Resistance: ≥500MΩ/km 20℃

5) Insulation Resistance of High Temperature: 5MΩ/km

6) A.C. Voltage Withstand Test: 1000V 50Hz 5min

7) Capacitance: ≤0.13 μ F/km 800-1000Hz

8) Breaking Strength: 55kN

9) Working Tension: <24kN

10) Minimum Sheave Diameter: 450mm

11) Stretch Coefficient: 1.35m/km/5kN

12) Working Temperature for Long-term: 125℃

13) Temperature Range: -30℃ ~ 150℃

14) Weight of Cables: 286kg/km

15) The length of cable delivery is between 3000 meters and 8000 meters( between 9843ft and 26248ft) per reel, allowable deviation is -2%~3%. Any length can be delivered by mutual agreement.

Note: If choose the anti-sulfur cable, the breaking strength will be 85% of the value.

W1B—8.0 1*1.0

1) O.D. of Cable: 8.0mm

2) O.D. Inner Armor: 5.7mm

3) Conductor DC Resistance: ≤18 Ω/km 20℃

4) Insulation Resistance: ≥500MΩ/km 20℃

5) Insulation Resistance of High Temperature: 2.5MΩ/km

6) A.C. Voltage Withstand Test: 1000V 50Hz 5min

7) Capacitance: ≤0.13 μ F/km 800-1000Hz

8) Breaking Strength: 55kN

9) Working Tension: <25kN

10) Minimum Sheave Diameter: 450mm

11) Stretch Coefficient: 1.35m/km/5kN

12) The length of cable delivery is between 3000 meters and 8000 meters( between 9843ft and 26248ft) per reel, allowable deviation is -2%~3%. Any length can be delivered by mutual agreement.

Note: If choose the anti-sulfur cable, the breaking strength will be 85% of the value.

5. Delivery Requirement:

The cable should be wrapped closely and tightly on the reel of which the diameter is not less than 5 0 times of the cable diameter, and there shouldn't be any loose. Both ends of the cable should be se aled, and the extra cable of the reel should not be less than 300mm.

6. Storage and transportation:

6.1 The cable should be avoided outdoor storage, and the reel should be stand on the ground.
6.2 It is not allowed to throw the reel with cable from high place during the transportation, mechan ical damage is neither allowed.

6.3 When packing while hanging, it is not allowed to hang several reels together. The cable reel sho uld be placed stably on the track and ship and fixed well with proper method to avoid hitting and tu rning over.

Ubicación : No.2 Tongxing Road, Dongying City, Shandong Province, China, 257500 KENLI,
Persona a contactar : Jassy Shang, 86 546 2062099

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
Single-core Logging Cable

Buscar en la categoria : Bienes de equipo
Buscar en la categoria :
cable, logging, core, single
Francia 528300 Artesania
Bulb Light UVWL12BLXX93

Wednesday 22 May 2024

Bulb Light UVWL12BLXX93 Bulb light applied with patented LED technology. It can sterlize the air and surface around while offer general ligting. Specification of Bulb Light UVWL12BLXX93 Model Input Voltage Power Efficacy CCT CRI Size Package Bulb Light UVWL12BLXX93 AC100-265V...

Foshan Feiliu Enterprise Management co.LTD

  • 528300 - Foshan
  • 86 757 29311003
Francia 200030 B2B Servicios
Chemical Management Software

Thursday 24 August 2023

Reliability, Reliability, and Reliability. This is what all maintenance teams will focus on in the chemical plants, reliability can be easily obtained through EAMic® CMMS: System embedded failure analysis report, ultra red and vibration pen (equipment temperature and vibration data...)

  • 200030 - shanghai
  • 021 6958 0696
Alemania 60386 Informática
Netgear Switch 24 ports 10 Gigabit / Multi-Gigabit plus avec 2 ports SFP+ dédiés - XS72...

Thursday 30 June 2022

Cantidad : 100

En tant que principal fournisseur d'équipements réseaux pour les PME, NETGEAR® comprend l'importance de fournir du matériel réseau fiable et hautes performances. Avec le développement de la virtualisation, des services cloud et des applications comme la VoIP, les flux vidéo et la surveillance IP...

MaKant Europe GmbH & Co. KG

  • 60386 - Frankfurt am Main
  • +49 (69) 9 150 750 14