Solution For Bubble Overflow In HPLC Column
There are bubbles in the mobile phase, the pump is turned off, the pressure relief valve is opened, the purge button is turned on, the degas is cleaned, the bubbles are continuously ejected from the HPLC column, and the mobile phase enters the mobile phase. No matter how many times the purge button is turned on, the continuously generated bubbles cannot be removed.
Syringe filter is immersed in a buffer such as ammonium acetate for a long time. The inside of the filter grows due to the growth of mold, forming a cluster of bacteria, blocking the filter. The buffer is difficult to smoothly pass through the HPLC column, and the air enters the mobile phase through the filter under the pressure of the pump.
The treatment filter is immersed in a 5% nitric acid solution and ultrasonically cleaned for a few minutes. The filter can also be immersed in a 5% nitric acid solution for 12 to 36 hours, gently vortexed several times, and then the filter is washed several times with pure water. Open the pressure relief valve, open the purge button to clean the degassing.
If there are still bubbles emerging from the HPLC column continue to soak the filter in a 5% nitric acid solution. If there are no bubbles, the filter will emerge from the filter. The internal mold flora has been destroyed by nitric acid and the mobile phase can pass through the filter smoothly. Open the pressure relief valve, turn on the pump, adjust the flow rate to 1.0 ~ 3.0ml / min, rinse the filter with pure water for about 1 hour. The filter can be cleaned. Close the pressure relief valve and rinse with pure methanol for half an hour.
Persona a contactar : Bruce Lu, +86 29 89284429
Buen trato: comprar del vendedor
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
|
Esta página es acerca de los importadores y exportadores de Solution For Bubble Overflow In HPLC Column Buscar en la categoria : Varios / Descuento Buscar en la categoria : overflow, bubble, solution, column, hplc |
Thursday 22 January 2026
Palets de devoluciones Action para mayoristas, liquidación profesional y exporta
Cantidad : 30000 - Precio : 0,50 €
Ofrecemos palets de devoluciones compuestos exclusivamente por artículos procedentes de la cadena Action, dirigidos a mayoristas, profesionales del liquidación, revendedores y exportadores. Estos palets de liquidación contienen productos de gran consumo no alimentarios, seleccionados por su alto potencial de reventa y rápida rotación. Detalles de la oferta: - Palets de devoluciones de gran distribución – marca Action - Aprox. 1.000 artículos por palet (80 % de los palets) - Precio medio...
TRANSIDI
- 22440 - PLOUFRAGAN
- 09 72 63 03 26
- 33(0)603670505
Friday 04 March 2016
Cantidad : 150 - Precio : 280,00 €
Vous vérifiez vos dizaines et des dizaines de fois par jour iPhone, probablement plus. La saisie d'un mot de passe chaque fois que vous ralentit juste. Mais vous le faites parce que faire en sorte que personne d'autre n'a accès à votre iPhone est important. Avec iPhone 5s, entrer...
Electronics Design Services
- CM23 2JP - Hertfordshire
- +447405858765
Friday 15 December 2017
online katalogOEM PART NO DESCRİPİTİON 66072 Crown Wheel and Pinion FOR CARRARO 13X30 66941 Crown Wheel and Pinion 15x37 2277448 CATERPİLLAR AİR FİLTER OUTER 2277449 CATERPİLLAR AİR FİLTER İNNER 01/117901 FAN BELT 01/124403 FAN BELT 01/124404 02/100073 Oil Filter Canister Type, MEDİUM...
ANAC MAKINA CO LTD STI
- 34800 - İSTANBUL
- +905069691531
- +9005069691531