Detection method:

Adopts the half-cell potential method to test the rebar corrosion condition in the concrete structure; adopts the Wenner sensor (Spacing is 50mm) to test the concrete resistivity

Detector:

concrete rebar corrosion potential, concrete resistivity

Standard:

GB/T50344-2004 Technical standard for inspection of building structure

JGJ/T 152-2008 Technical specification for test of reinforcing steel bar in concrete

Application:

The equipment can test the rebar corrosion potential in the concrete structure based on the potential testing mode, and it can test any structure with different surface area and direction. Under the concrete resistivity testing mode, the equipment can test the resistivity to evaluate the corrosion possibility in concrete structure. Both methods can evaluate the rebar corrosion possibility in the concrete structure.

Feature:

1. Two methods for rebar corrosion potential testing( direct method and gradient method) are suitable to different test field.

2. 0~2000 kΩ cm large range concrete resistivity testing

3. Large touch color screen to display and control, convenient usage, and additional keyboard for inputting

4. The screen can display corrosion potential color histogram directly, the user can evaluate the corrosion degree onsite quickly.

5. Multi-functional PC can store and process the data.

6. Rechargeable lithium batteries to ensure long working hours

7. Mini printer for printing directly.

Parameter:

Range: 0~2000 kΩcm,±1000mV

Display resolution: 0.1 kΩcm,1mV

Storage: 128 groups

PC communication parameter: 115200 baud rate

LCD : 640*480

Host dimension: 160*115*50mm

Ubicación : No 21,Linhe North Road,Shunyi Dist,, 101320 Beijing,
Persona a contactar : Jack Guo, +86 10 59429575

Buen trato: comprar del vendedor

Visita nuestra guía para una transacción segura! En ningún caso Algomtl no se hace responsable de los anuncios. Sólo la responsabilidad del vendedor o del comprador en caso de litigio está involucrado.
Por favor, lea nuestras condiciones de uso. También puede visitar nuestras preguntas frecuentes y ver nuestra información sobre los riesgos relacionados con la falsificación.
Esta página es acerca de los importadores y exportadores de
SY-CR Concrete resistivity and rebar corrosion tester

Buscar en la categoria : Bienes de equipo
Buscar en la categoria :
concrete, resistivity, corrosion, rebar, tester
Australia 6021 Varios / Descuento
Sustainable Packaging

Thursday 13 October 2022

Precio : 1-10usd

Check out our variety of eco packaging solutions. All of which can be completely customised to suit your ideal brand image. The benefits of sustainable packaging are endless, it reduces single use materials and promotes recyclability, diverts waste from landfill and creates a sustainable...

Myerton Packaging Pty Ltd

  • 6021 - Australia
  • 1300089850
Indonesia 80235 B2B Servicios
Foto no disponible

Saturday 17 January 2026

Cantidad : 1 - Precio : $2,026.00

Si busca el Cabezal de impresión Kyocera KJ4B-QL06NT0-EN10V, printerheadwholesaler.com es la mejor opción. Contamos con el conocimiento y la experiencia necesarios para ofrecerle soluciones y servicios empresariales de calidad, fiables y rentables. ¡Contáctenos ahora! ¡Compre ya!...

PrinterheadWholesaler

Francia 528300 Vehiculos
COB SW1919-40W-40FR90

Friday 29 December 2023

405nm is widely using in disinfection, bacterial disease cure,or microbial infection prevention etc. It does no harm to human. But it's blue not friendly for eye view. Feton LED chip model COB SW1919-40W-40FR90 emits this disinfection blue light as white. Lighting while disinfection...

Foshan Feiliu Enterprise Management co.LTD

  • 528300 - Foshan
  • 86 757 29311003